6
Inspection/maintenance
Lubricant change intervals
Assembly and Operating Instructions – Explosion-Proof Gear Units
112
6.3
Lubricant change intervals
The following image depicts the change intervals for standard gear units under normal
ambient conditions. In case of special designs under severe/aggressive ambient con-
ditions, change the lubricant more frequently.
5000
10000
15000
20000
25000
30000
h
120
°C
110
115
100
90
80
70
0
[1]
[2]
[4]
[5]
[3]
[6]
[7]
27021597782952587
[1]
Operating hours
[4]
CLP HC/ CLP HC NSF H1
[2]
Sustained oil bath tempera-
ture
[5]
CLP (CC)/E
•
Average value per oil type
at 70 °C
[6]
SEW GearOil Base
[3]
CLP PG/CLP PG NSF H1
[7]
SEW GearOil Poly (H1)
6.4
Maintenance of AL/AM/AQ. adapter
The following table lists the obligatory intervals and the corresponding measures:
Time interval
What to do?
•
Every 3000 operating
hours, at least every 6
months
•
Check the running noises to detect possible
bearing damage.
•
Visually check the adapter for leakage.
•
After 10000 operating
hours
•
Check the rotational clearance.
•
Visual check the cam ring (AM) or coupling ring
(AQ., AL).
•
After 10 000 operating
hours with NBR/FKM oil
seals
•
After 20 000 operating
hours with Premium Sine
Seal (PSS) adapter oil
seals:
•
Change the bearing grease.
•
Change the oil seal. With standard NBR or FKM
oil seals, the new oil seal must not be fitted on
the previous track. This is allowed with Premium
Sine Seal (PSS) adapter oil seals.
24804134/EN – 05/2018