7
Startup
Prerequisites for startup
Addendum to the Operating Instructions – Synchronous Servomotors CMP40 – 112, CMPZ71 – 100
21
7
Startup
7.1
Prerequisites for startup
DANGER
Risk of injury due to electric shock.
Severe or fatal injuries.
•
Observe the safety notes in chapter 2 during installation.
•
Switch contacts in utilization category AC-3 according to EN 60947-4-1 must be
used for switching the motor and the brake.
•
When motors are powered by inverters, you must adhere to the wiring instruc-
tions issued by the inverter manufacturer.
•
Observe the operating instructions of the servo inverter.
DANGER
Disabling functional safety devices.
Severe or fatal injuries.
•
Only qualified personnel is allowed to carry out work on functional safety com-
ponents.
•
Any work on functional safety components must be carried out by strictly ob-
serving the specifications in the operating instructions at hand and the respective
addendum to the operating instructions. Else, the right to claim under warranty
will become invalid.
INFORMATION
The rated speed of the motor in a gearmotor can be higher than the permitted, input
speed of the gear unit.
Limit the maximum speed at the servo inverter. For information on the procedure,
refer to the documentation of the servo inverter.
22491465/EN – 03/2016