24
12.0 DATUM 2000
™
meter and manometer specifications
Display
Type
Light emitting diode
Color
Red
Height of digits
0.56 inch
Maximum readout
Reading rate
-9999 to +31999
2 to 3 times per second depending on input voltage
Overload signal (over range reading)
OVEr
Underload signal (under range reading)
UndEr
Polarity sign
Negative only
Brightness
Constant
Cutout dimensions
Meter
1/8 DIN: 1.77 in. x 3.62 in. (45 x 92 mm)
Manometer
1/4 DIN: 3.54 in. x 3.62 in. (90 x 92 mm)
Front panel
Meter
3.85 in. x 1.99 in. (98 x 50 mm)
Manometer
3.85 in. x 3.74 in. (98 x 95 mm)
Accuracy (readout only)
At 73°F (23°C)
±0.01%R ± 1 digit
At 60°F to 95°F (16° to 35°C)
±0.04%R ± 1 digit
Analog output
Transducers
Same as transducer output voltage
Transmitters
No analog output; the DATUM 2000™ terminates the
current loop
Physical
Operating temperature
32° to 130°F (0° to 55°C)
Storage temperature
-40° to185°F(-40° to 85°C)
Width
3.59 inches (91mm)
Height
Meter
Manometer
1.74 inches (91mm)
3.50 (89mm)
Electrical data
Power
Domestic
24 VDC (115 VAC 60 Hz 12 watt adapter provided w/-1 models)
Power cord length
6 feet (approx.)
Depth (incl. connector)
7 inches (178 mm)
(Allow at least 1/2" more for wires attached to terminal strip)