T
RIGGERING
LVDT9312
F
UNCTIONS
V
IA
F
UNCTIONS
-VI
S
The Functions-
VI’s are located in the „SET_
LVDT_9312
_Functions.lvlib“. Note that
each chassis slot requires a
specific functions-
VI. (e.g. slot 1, slot 2 …)
Calling a LVDT9312 function via the Functions-VI
When a Function-VI is executed, instructions and data are transferred to the corresponding FIFOs
„SlotN_CommandIN“. The applicable driver
-VI then communicates with the LVDT9312 module via the driver
internal FIFO „SlotN_CommandOUT“.
Driver internal FIFOs for data transfer between Function-VI and Driver-VI (Slot1 example)