Servomech ATL 02 Installation, Operation And Maintenance Manual Download Page 3

Servomech S.p.A. 

02.02-05-08-10-11-12.E - Rev. 00 Date (M/Y) 12/19 

LINEAR ACTUATORS ATL/BSA 02 - 05 - 08 - 10 - 12 - 12 

Installation, operation and maintenance manual 

Contents 

MODELS COVERED BY THIS DOCUMENT .................................................................................................... 4 

IDENTIFICATION OF THE MANUFACTURER AND THE PRODUCT ................................................................ 4 

2.1 

Identification of the manufacturer ..................................................................................................... 4 

2.2 

Description of the product ................................................................................................................. 4 

2.3 

Identification of the product .............................................................................................................. 5 

2.4 

Identification label position ................................................................................................................ 5 

TRASPORT AND HANDLING ........................................................................................................................ 6 

USE RESTRICTION ....................................................................................................................................... 6 

4.1 

Intended use ....................................................................................................................................... 6 

4.1.1 

Use restrictions ........................................................................................................................... 7 

4.1.2 

Standard operating conditions ................................................................................................... 7 

4.1.3 

Thermal limit .............................................................................................................................. 7 

4.2 

Personnel requirements / Qualifications ........................................................................................... 8 

STORAGE ..................................................................................................................................................... 8 

INSTALLATION ............................................................................................................................................ 8 

6.1 

Safety warnings .................................................................................................................................. 8 

6.2 

FCE electric stroke limit switches .....................................................................................................10 

6.3 

FCM magnetic stroke limit switches .................................................................................................11 

6.4 

Rotary encoder EH38 ........................................................................................................................13 

6.5 

Safety clutch FS .................................................................................................................................14 

6.6 

Electric motor wiring ........................................................................................................................15 

6.6.1 

AC 3-phase asynchronous motor .............................................................................................15 

6.6.2 

AC 1-phase asynchronous motor with balanced winding ........................................................16 

6.6.3 

DC motor ..................................................................................................................................17 

6.7 

Linear actuator installation ..............................................................................................................18 

6.8 

Installation of rod end fitting elements ............................................................................................19 

COMMISSIONING AND USE ......................................................................................................................20 

LUBRICATION ............................................................................................................................................21 

MAINTENANCE .........................................................................................................................................21 

Summary of Contents for ATL 02

Page 1: ...ATL 08 ATL 10 ATL 12 BSA 08 BSA 10 BSA 11 BSA 12 Installation operation and maintenance manual Publication 02 02 05 08 10 11 12 E Rev 00 Date M Y 12 19 Servomech S p A Via M Calari 1 40011 Anzola del...

Page 2: ...ely relieve Servomech S p A from any liability for damage caused to persons and or property Servomech S p A it does not assume direct or indirect responsibility for an improper use of the actuator not...

Page 3: ...ICTION 6 4 1 Intended use 6 4 1 1 Use restrictions 7 4 1 2 Standard operating conditions 7 4 1 3 Thermal limit 7 4 2 Personnel requirements Qualifications 8 5 STORAGE 8 6 INSTALLATION 8 6 1 Safety war...

Page 4: ...dell Emilia BO ITALY Ph 39 051 6501 711 Fax 39 051 7345 74 Website www linearmech com e mail sales linearmech com 2 2 Description of the product For all the technical characteristics of the product p...

Page 5: ...oduct Figure 2 2 Product identification label On the actuator label following data are printed CODE article code DESCR product description the mining of symbols and their sequence are indicated on the...

Page 6: ...lder to design the application in compliance with the laws in force in the specific sector and in the field of safety in compliance with the requirements provided in the product catalog and in this ma...

Page 7: ...at conditions are in charge of the owner and where applicable are in charge of the end user The actuator must be installed and used indoor only in dry area with environmental conditions as specified b...

Page 8: ...IS REQUIRED STROKE END LIMIT SWITCHES MICROSWITCHES OR SENSORS MUST BE CONTROLLED TO BE SURE THE LINEAR MOVEMENT OF THE ACTUATOR DUE TO THE OPERATION OF THE MOTOR OR TO THE INERTIA OF THE MOVING PART...

Page 9: ...PARAMETERS ERRORS OPERATION IN CONDITIONS OUTSIDE THE SPECIFICATIONS PROVIDED BY THE CATALOG AND THIS MANUAL MAKE SURE THE SAFETY PROTECTION OF THE MACHINE MECHANICAL AND ELECTRICAL ARE ACTIVE DURING...

Page 10: ...limit switches Ring 1 activates FC 1 switch and fixes the required RETRACTED ACTUATOR stop position Ring 2 activates FC 2 switch and fixes the required EXTENDED ACTUATOR stop position To setup the st...

Page 11: ...now the actual stroke please refer to the product catalogue When using more contact reeds for intermediate positions it shall be considered that the same reed switch can give the signal in 2 different...

Page 12: ...REED SWITCHES TECHNICAL FEATURES Contact NC NO Switching output Reed Supply voltage 5 120 V AC DC 1 5 230 V AC DC 2 Voltage drop 0 35 V Continous current 100 mA AC Switching capacity 6 W Protection c...

Page 13: ...m The EH38 encoder must be connected to the electric control circuit as shown in the following WIRING DIAGRAM Figure 6 3 Encoder EH38 NOTE the safety clutch cannot be used with encoder EH38 because w...

Page 14: ...each actuator as stated on the performance tables in the catalogue On request a different preload can be set to achieve different performance If an overload is applied on the actuator the safety clutc...

Page 15: ...r with DC brake directly powered with rectifier In case of brake motor the brake is NORMALLY CLOSED NEGATIVE action When the power supply is switched off the brake is engaged The brake opens only when...

Page 16: ...phase motor with DC brake separately powered AC 1 phase with rectifier In case of brake motor the brake is NORMALLY CLOSED NEGATIVE action When the power supply is switched off the brake is engaged Th...

Page 17: ...In case of brake motor the brake is NORMALLY CLOSED NEGATIVE action When the power supply is switched off the brake is engaged The brake opens only when power is supplied the brake is wired separately...

Page 18: ...ECHANICAL AND ELECTRICAL PROTECTION MUST BE INSTALLED AND ACTIVATED TO PREVENT DAMAGE TO PERSONS OR PROPERTY Check that all plant fixing elements are well machined and cleaned and that they fit the di...

Page 19: ...not correct RIGHT WORKING OF THE ACTUATOR AND PLANT CANNOT BE GUARANTED IF SIDE OR NOT AXIAL LOAD ARE APPLIED TO THE ACTUATOR 6 8 Installation of rod end fitting elements To install a mounting element...

Page 20: ...as to be moved Measure the initial length of the actuator then run the actuator GRADUALLY from the control unit in order to reach the plant to its more distant extreme position Check continuously the...

Page 21: ...olit FLM 2 NLGI 2 Grease NLGI 1 DIN 51818 LUBCON Thermoplex ALN 1001 Also suitable FUCHS Renolit DURAPLEX EP 2 NLGI 2 AGIP Grease AC 1 NLGI 1 MOBIL Mobilgrease FM 101 NLGI 1 KLUBER Klubersynth UH1 14...

Reviews: