Servomech ATL 02 Installation, Operation And Maintenance Manual Download Page 7

Servomech S.p.A. 

02.02-05-08-10-11-12.E - Rev. 00 Date (M/Y) 12/19 

4.1.1

 

Use restrictions 

Actuators can not be used for unforeseen applications. 
Any utilization of this device beyond its intended purpose may lead to potentially hazardous situations. 
Therefore: 

 

Strictly adhere to all safety precautions and instructions in this operating manual. 

 

Do not allow this device to be subjected to weather conditions, strong UV rays, corrosive or explosive 
air media as well as other aggressive media (*). 

 

Do not modify, retool or change the structural design or individual components of the actuator. 

 

Never use the device outside of the technical application and operational limits.

 

(*) – THE USE OF THE ACTUATOR IN ABOVE CONDITIONS MUST BE PREVIOUSLY DECLARED AND AGREED 
WITH SERVOMECH, SINCE A SPECIAL EQUIPMENT OF THE PRODUCT MUST BE PROVIDED. 

4.1.2

 

Standard operating conditions 

The actuator must be used in an environment whose conditions comply with the provisions of Servomech 
S.p.A. The works necessary for obtaining and maintaining that conditions are in charge of the owner and,  
where applicable, are in charge of the end user. 
The actuator must be installed and used indoor only, in dry area with environmental conditions as specified 
below: 

 

Temperature range 

 

 

 

 

+0°C ÷ +40°C 

 

Relative atmospheric humidity   

 

 

5% ÷ 85% 

 

No build up of condensation 

Linear  actuator  must  be  installed  and  used  in  a  room  with  a  constant  illumination  of  500lux  at  least, 
complaining the norm UNI EN 1837:2009, or complaining specific norms related to specific application fields. 

 

THE USE OF THE ACTUATOR IN DIFFERENT CONDITIONS THAN JUST DESCRIBED MUST BE PREVIOUSLY 
DECLARED AND AGREED WITH SERVOMECH, SINCE A SPECIAL EQUIPMENT OF THE PRODUCT MUST 
BE PROVIDED. 

4.1.3

 

Thermal limit 

The actuator duty cycle permissible Fu [%] is the maximum working time expressed in percentage that the 
actuator  can  perform  during  the  reference  time  period  of  10  minutes,  under  rated  load  stated  in  the 
catalogue at ambient temperature 25°C, without risk of internal parts overheating. 

𝑭

𝒖

[%] =

𝑀𝑎𝑥 𝑤𝑜𝑟𝑘𝑖𝑛𝑔 𝑡𝑖𝑚𝑒 𝑜𝑣𝑒𝑟 10 𝑚𝑖𝑛

10 𝑚𝑖𝑛

× 100

 

Actuator 

Fu [%] 

ATL 02 with DC motor 

15 

ATL 02 with AC motor 

30 

ATL 05 

15 

ATL 08 

15 

ATL 10 

30 

ATL 12 

30 

BSA 08 

50 

BSA 10 

100 

BSA 11 

100 

BSA 12 

100 

 

For the proper operation do never exceed the permissible duty cycle limit. 

Summary of Contents for ATL 02

Page 1: ...ATL 08 ATL 10 ATL 12 BSA 08 BSA 10 BSA 11 BSA 12 Installation operation and maintenance manual Publication 02 02 05 08 10 11 12 E Rev 00 Date M Y 12 19 Servomech S p A Via M Calari 1 40011 Anzola del...

Page 2: ...ely relieve Servomech S p A from any liability for damage caused to persons and or property Servomech S p A it does not assume direct or indirect responsibility for an improper use of the actuator not...

Page 3: ...ICTION 6 4 1 Intended use 6 4 1 1 Use restrictions 7 4 1 2 Standard operating conditions 7 4 1 3 Thermal limit 7 4 2 Personnel requirements Qualifications 8 5 STORAGE 8 6 INSTALLATION 8 6 1 Safety war...

Page 4: ...dell Emilia BO ITALY Ph 39 051 6501 711 Fax 39 051 7345 74 Website www linearmech com e mail sales linearmech com 2 2 Description of the product For all the technical characteristics of the product p...

Page 5: ...oduct Figure 2 2 Product identification label On the actuator label following data are printed CODE article code DESCR product description the mining of symbols and their sequence are indicated on the...

Page 6: ...lder to design the application in compliance with the laws in force in the specific sector and in the field of safety in compliance with the requirements provided in the product catalog and in this ma...

Page 7: ...at conditions are in charge of the owner and where applicable are in charge of the end user The actuator must be installed and used indoor only in dry area with environmental conditions as specified b...

Page 8: ...IS REQUIRED STROKE END LIMIT SWITCHES MICROSWITCHES OR SENSORS MUST BE CONTROLLED TO BE SURE THE LINEAR MOVEMENT OF THE ACTUATOR DUE TO THE OPERATION OF THE MOTOR OR TO THE INERTIA OF THE MOVING PART...

Page 9: ...PARAMETERS ERRORS OPERATION IN CONDITIONS OUTSIDE THE SPECIFICATIONS PROVIDED BY THE CATALOG AND THIS MANUAL MAKE SURE THE SAFETY PROTECTION OF THE MACHINE MECHANICAL AND ELECTRICAL ARE ACTIVE DURING...

Page 10: ...limit switches Ring 1 activates FC 1 switch and fixes the required RETRACTED ACTUATOR stop position Ring 2 activates FC 2 switch and fixes the required EXTENDED ACTUATOR stop position To setup the st...

Page 11: ...now the actual stroke please refer to the product catalogue When using more contact reeds for intermediate positions it shall be considered that the same reed switch can give the signal in 2 different...

Page 12: ...REED SWITCHES TECHNICAL FEATURES Contact NC NO Switching output Reed Supply voltage 5 120 V AC DC 1 5 230 V AC DC 2 Voltage drop 0 35 V Continous current 100 mA AC Switching capacity 6 W Protection c...

Page 13: ...m The EH38 encoder must be connected to the electric control circuit as shown in the following WIRING DIAGRAM Figure 6 3 Encoder EH38 NOTE the safety clutch cannot be used with encoder EH38 because w...

Page 14: ...each actuator as stated on the performance tables in the catalogue On request a different preload can be set to achieve different performance If an overload is applied on the actuator the safety clutc...

Page 15: ...r with DC brake directly powered with rectifier In case of brake motor the brake is NORMALLY CLOSED NEGATIVE action When the power supply is switched off the brake is engaged The brake opens only when...

Page 16: ...phase motor with DC brake separately powered AC 1 phase with rectifier In case of brake motor the brake is NORMALLY CLOSED NEGATIVE action When the power supply is switched off the brake is engaged Th...

Page 17: ...In case of brake motor the brake is NORMALLY CLOSED NEGATIVE action When the power supply is switched off the brake is engaged The brake opens only when power is supplied the brake is wired separately...

Page 18: ...ECHANICAL AND ELECTRICAL PROTECTION MUST BE INSTALLED AND ACTIVATED TO PREVENT DAMAGE TO PERSONS OR PROPERTY Check that all plant fixing elements are well machined and cleaned and that they fit the di...

Page 19: ...not correct RIGHT WORKING OF THE ACTUATOR AND PLANT CANNOT BE GUARANTED IF SIDE OR NOT AXIAL LOAD ARE APPLIED TO THE ACTUATOR 6 8 Installation of rod end fitting elements To install a mounting element...

Page 20: ...as to be moved Measure the initial length of the actuator then run the actuator GRADUALLY from the control unit in order to reach the plant to its more distant extreme position Check continuously the...

Page 21: ...olit FLM 2 NLGI 2 Grease NLGI 1 DIN 51818 LUBCON Thermoplex ALN 1001 Also suitable FUCHS Renolit DURAPLEX EP 2 NLGI 2 AGIP Grease AC 1 NLGI 1 MOBIL Mobilgrease FM 101 NLGI 1 KLUBER Klubersynth UH1 14...

Reviews: