4.2

 

Personnel requirements / Qualifications 

This  manual  must  be  made  available  to  the  personnel  in  charge  of  installation,  start  up  and  use  of  the  
actuator. It is the responsibility of the machine builder:  

 

use personnel with the necessary qualifications for the installation and commissioning of the 
actuator; 

 

periodically check the qualification of the assigned personnel; 

 

check that the personnel in charge are aware of the contents of this manual. 

5

 

STORAGE 

 

Do not store outside.  

 

Storage should be dry and dust-free. 

 

Keep away from any aggressive media. 

 

Protect from UV radiation. 

 

Avoid mechanical vibrations. 

 

Storage temperature:  0 to +50 °C. 

 

Relative atmospheric humidity: max. 95% (no build up of condensation). 

6

 

INSTALLATION 

The  operations  described  in  the  paragraphs  of  this  chapter  provide  both  electrical  and  mechanical 
connections of the actuator, as well as the execution of test motions at reduced speed and motor torque or 
with small displacement steps. 

6.1

 

Safety warnings 

 

MOTORS  CANNOT  BE  CONNECTED  DIRECTLY  TO  THE  ELETRICITY  GRID.  A  PROPER  CIRCUITS  AND 
DEVICES FOR MOVEMENT MANAGEMENT ON BOTH DIRECTIONS IS REQUIRED. STROKE END LIMIT 
SWITCHES  (MICROSWITCHES  OR  SENSORS)  MUST  BE  CONTROLLED  TO  BE  SURE  THE  LINEAR 
MOVEMENT OF THE ACTUATOR (DUE TO THE OPERATION OF THE MOTOR OR TO THE INERTIA OF 
THE MOVING PARTS) STOPS BEFORE TO REACH THE MECHANICAL STROKE END LIMITS. IN CASE THIS 
HAPPENS, THE ACTUATOR CAN BE LOCKED AND THE INTERNAL COMPONENTS CAN BE DAMAGED. 

 

WHEN THE MOTORS MUST BE POWERED BY A CONVERTER (ELECTRIC DRIVE), THIS MUST BE CHOSEN 
BY QUALIFIED PERSONNEL. 

 

IN  CASE  THERE  ARE  INVOLVED  ELECTRONIC  DRIVE  AND  CONTROL  DEVICES  ON  THE  ACTUATOR 
MOVING  CONTROL,  REFER  TO  MANUALS  FOR  ALL  THE  NECESSARY  INFORMATION  AND  CORRECT 
INSTALLATION AND MAINTENANCE OF THE PRODUCT. 

 

BEFORE TO PROCEED TO THE ELECTRIC CONNECTION, MAKE SURE THE SUPPLY VOLTAGE IS TURNED 
OFF. 

 

BEFORE TO TURN-ON THE MOTOR, MAKE SURE THE ELECTRIC CONNECTIONS ARE TIGHTENED AND 
STABLE. 

 

CHECK  POWER  SUPPLY  CABLES  NOT  TO  BE  DAMAGED  DURING  THE  COMMISSIONING.  POWER 
SUPPLY CABLES MUST BE OUT OF HEAT SOURCES AND MOVING ORGANS. 

 

DURING FUNCTIONING ARE PRODUCED MAGNETIC, ELECTRIC AND ELECTROMAGNETIC FIELDS. THIS 
MAY  BE  DANGEROUS  FOR  PEOPLE  THAT  USE  CARDIAC  STIMULATOR  (PACEMAKER),  IF  NOT 
SUFFICIENT DISTANCE. 

 

DO NOT DISCONNECT ANY CONNECTION DURING OPERATION OR IN PRESENCE OF SUPPLY VOLTAGE. 

 

BEFORE TO TURN-ON THE MOTOR, MAKE SURE THE MECHANICAL CONNECTIONS OF THE ACTUATOR 
REMAIN TIGHTENED AND STABLE, ALSO DURING THE OPERATION. 

Summary of Contents for ATL 02

Page 1: ...ATL 08 ATL 10 ATL 12 BSA 08 BSA 10 BSA 11 BSA 12 Installation operation and maintenance manual Publication 02 02 05 08 10 11 12 E Rev 00 Date M Y 12 19 Servomech S p A Via M Calari 1 40011 Anzola del...

Page 2: ...ely relieve Servomech S p A from any liability for damage caused to persons and or property Servomech S p A it does not assume direct or indirect responsibility for an improper use of the actuator not...

Page 3: ...ICTION 6 4 1 Intended use 6 4 1 1 Use restrictions 7 4 1 2 Standard operating conditions 7 4 1 3 Thermal limit 7 4 2 Personnel requirements Qualifications 8 5 STORAGE 8 6 INSTALLATION 8 6 1 Safety war...

Page 4: ...dell Emilia BO ITALY Ph 39 051 6501 711 Fax 39 051 7345 74 Website www linearmech com e mail sales linearmech com 2 2 Description of the product For all the technical characteristics of the product p...

Page 5: ...oduct Figure 2 2 Product identification label On the actuator label following data are printed CODE article code DESCR product description the mining of symbols and their sequence are indicated on the...

Page 6: ...lder to design the application in compliance with the laws in force in the specific sector and in the field of safety in compliance with the requirements provided in the product catalog and in this ma...

Page 7: ...at conditions are in charge of the owner and where applicable are in charge of the end user The actuator must be installed and used indoor only in dry area with environmental conditions as specified b...

Page 8: ...IS REQUIRED STROKE END LIMIT SWITCHES MICROSWITCHES OR SENSORS MUST BE CONTROLLED TO BE SURE THE LINEAR MOVEMENT OF THE ACTUATOR DUE TO THE OPERATION OF THE MOTOR OR TO THE INERTIA OF THE MOVING PART...

Page 9: ...PARAMETERS ERRORS OPERATION IN CONDITIONS OUTSIDE THE SPECIFICATIONS PROVIDED BY THE CATALOG AND THIS MANUAL MAKE SURE THE SAFETY PROTECTION OF THE MACHINE MECHANICAL AND ELECTRICAL ARE ACTIVE DURING...

Page 10: ...limit switches Ring 1 activates FC 1 switch and fixes the required RETRACTED ACTUATOR stop position Ring 2 activates FC 2 switch and fixes the required EXTENDED ACTUATOR stop position To setup the st...

Page 11: ...now the actual stroke please refer to the product catalogue When using more contact reeds for intermediate positions it shall be considered that the same reed switch can give the signal in 2 different...

Page 12: ...REED SWITCHES TECHNICAL FEATURES Contact NC NO Switching output Reed Supply voltage 5 120 V AC DC 1 5 230 V AC DC 2 Voltage drop 0 35 V Continous current 100 mA AC Switching capacity 6 W Protection c...

Page 13: ...m The EH38 encoder must be connected to the electric control circuit as shown in the following WIRING DIAGRAM Figure 6 3 Encoder EH38 NOTE the safety clutch cannot be used with encoder EH38 because w...

Page 14: ...each actuator as stated on the performance tables in the catalogue On request a different preload can be set to achieve different performance If an overload is applied on the actuator the safety clutc...

Page 15: ...r with DC brake directly powered with rectifier In case of brake motor the brake is NORMALLY CLOSED NEGATIVE action When the power supply is switched off the brake is engaged The brake opens only when...

Page 16: ...phase motor with DC brake separately powered AC 1 phase with rectifier In case of brake motor the brake is NORMALLY CLOSED NEGATIVE action When the power supply is switched off the brake is engaged Th...

Page 17: ...In case of brake motor the brake is NORMALLY CLOSED NEGATIVE action When the power supply is switched off the brake is engaged The brake opens only when power is supplied the brake is wired separately...

Page 18: ...ECHANICAL AND ELECTRICAL PROTECTION MUST BE INSTALLED AND ACTIVATED TO PREVENT DAMAGE TO PERSONS OR PROPERTY Check that all plant fixing elements are well machined and cleaned and that they fit the di...

Page 19: ...not correct RIGHT WORKING OF THE ACTUATOR AND PLANT CANNOT BE GUARANTED IF SIDE OR NOT AXIAL LOAD ARE APPLIED TO THE ACTUATOR 6 8 Installation of rod end fitting elements To install a mounting element...

Page 20: ...as to be moved Measure the initial length of the actuator then run the actuator GRADUALLY from the control unit in order to reach the plant to its more distant extreme position Check continuously the...

Page 21: ...olit FLM 2 NLGI 2 Grease NLGI 1 DIN 51818 LUBCON Thermoplex ALN 1001 Also suitable FUCHS Renolit DURAPLEX EP 2 NLGI 2 AGIP Grease AC 1 NLGI 1 MOBIL Mobilgrease FM 101 NLGI 1 KLUBER Klubersynth UH1 14...

Reviews: