Servomech ATL 02 Installation, Operation And Maintenance Manual Download Page 6

Servomech S.p.A. 

02.02-05-08-10-11-12.E - Rev. 00 Date (M/Y) 12/19 

3

 

TRASPORT AND HANDLING 

 

It is recommended to pay attention and care during the handling and transport of linear actuators 
not to damage mechanical parts and / or accessories and to prevent risks for the personnel in charge 
of this activity. 

 

The packaging must be lifted and moved with care and in a safe way. 

 

For lifting and transporting the linear actuator, the push rod must be in retracted position. 

 

Lift the actuator from the housing and outer tube, supporting the motor during transport. 

 

DO NOT lift the actuator only from the push rod and / or the motor. 

 

In the case of BSA series actuators, the ball screw inside the actuator is  NOT self-locking. Never lift 
the linear actuator upright from the push rod as the actuators could be back driven by its own weight. 

In  case  of  doubt,  consult SERVOMECH  S.p.A.  to  get the  appropriate  information  and  prevent  any  kind of 
damage! 

4

 

USE RESTRICTION 

The information contained in this chapter provides important prescriptions for operating safely during all 
phases of the product's life. 
Not  knowing  or  not  complying  with  these  provisions  can  generate  dangerous  situations  that  could  cause 
damage to equipment and risks for the safety of persons. 

4.1

 

Intended use 

Actuators are used to perform very different functions within machines. It is the responsibility of the machine 
builder to design the application in compliance with the laws in force in the specific sector and in the field of 
safety, in compliance with the requirements provided in the product catalog and in this manual. 

 

ACTUATORS ARE ELECTRIC AXIS, WHATEVER DRIVER OR CONTROL WILL BE USED: THE SELECTION OF 
THE PRODUCT AS STROKE, SPEED, TYPE OF LIMIT SWITCHES, MOTOR AND BRAKE, MUST BE DONE 
ACCORDING TO THE BEHAVIOR EXPECTED, IN FUNCTION OF THE TYPE OF CONTROL CHOOSEN AND 
THE STATIC AND DYNAMIC BEHAVIOR OF THE SYSTEM IN WHICH THE ACTUATOR IS PLACED! 

The  actuators  have  been  designed  and  built  to  operate  mobile  parts  of  various  types,  shapes  and 
construction, in the ways and within the limits set out in the descriptions and tables of the technical data in 
the catalog and in this user manual. 
The actuators are designed to work with a purely axial applied load. 
They must be subjected to the loading and speed conditions specified in the catalog. 
Modification of parts of the actuator or replacement of components with different and non-original parts is 
not permitted. The replacement of components with original spare parts is carried out only by Servomech 
S.p.A. 
Any different  use  is to be considered improper and therefore  potentially dangerous for the safety of the 
operators, as well as such as to void the contractual guarantee. 
In the event of particular processing requirements, we recommend consulting our sales department. 
Every modification must be authorized by Servomech S.p.A. with written documents. 

 

ANY OTHER USE OUTSIDE THAT THAT JUST DESCRIBED IS NOT PERMITTED BY SERVOMECH S.p.A. 

 

 

Summary of Contents for ATL 02

Page 1: ...ATL 08 ATL 10 ATL 12 BSA 08 BSA 10 BSA 11 BSA 12 Installation operation and maintenance manual Publication 02 02 05 08 10 11 12 E Rev 00 Date M Y 12 19 Servomech S p A Via M Calari 1 40011 Anzola del...

Page 2: ...ely relieve Servomech S p A from any liability for damage caused to persons and or property Servomech S p A it does not assume direct or indirect responsibility for an improper use of the actuator not...

Page 3: ...ICTION 6 4 1 Intended use 6 4 1 1 Use restrictions 7 4 1 2 Standard operating conditions 7 4 1 3 Thermal limit 7 4 2 Personnel requirements Qualifications 8 5 STORAGE 8 6 INSTALLATION 8 6 1 Safety war...

Page 4: ...dell Emilia BO ITALY Ph 39 051 6501 711 Fax 39 051 7345 74 Website www linearmech com e mail sales linearmech com 2 2 Description of the product For all the technical characteristics of the product p...

Page 5: ...oduct Figure 2 2 Product identification label On the actuator label following data are printed CODE article code DESCR product description the mining of symbols and their sequence are indicated on the...

Page 6: ...lder to design the application in compliance with the laws in force in the specific sector and in the field of safety in compliance with the requirements provided in the product catalog and in this ma...

Page 7: ...at conditions are in charge of the owner and where applicable are in charge of the end user The actuator must be installed and used indoor only in dry area with environmental conditions as specified b...

Page 8: ...IS REQUIRED STROKE END LIMIT SWITCHES MICROSWITCHES OR SENSORS MUST BE CONTROLLED TO BE SURE THE LINEAR MOVEMENT OF THE ACTUATOR DUE TO THE OPERATION OF THE MOTOR OR TO THE INERTIA OF THE MOVING PART...

Page 9: ...PARAMETERS ERRORS OPERATION IN CONDITIONS OUTSIDE THE SPECIFICATIONS PROVIDED BY THE CATALOG AND THIS MANUAL MAKE SURE THE SAFETY PROTECTION OF THE MACHINE MECHANICAL AND ELECTRICAL ARE ACTIVE DURING...

Page 10: ...limit switches Ring 1 activates FC 1 switch and fixes the required RETRACTED ACTUATOR stop position Ring 2 activates FC 2 switch and fixes the required EXTENDED ACTUATOR stop position To setup the st...

Page 11: ...now the actual stroke please refer to the product catalogue When using more contact reeds for intermediate positions it shall be considered that the same reed switch can give the signal in 2 different...

Page 12: ...REED SWITCHES TECHNICAL FEATURES Contact NC NO Switching output Reed Supply voltage 5 120 V AC DC 1 5 230 V AC DC 2 Voltage drop 0 35 V Continous current 100 mA AC Switching capacity 6 W Protection c...

Page 13: ...m The EH38 encoder must be connected to the electric control circuit as shown in the following WIRING DIAGRAM Figure 6 3 Encoder EH38 NOTE the safety clutch cannot be used with encoder EH38 because w...

Page 14: ...each actuator as stated on the performance tables in the catalogue On request a different preload can be set to achieve different performance If an overload is applied on the actuator the safety clutc...

Page 15: ...r with DC brake directly powered with rectifier In case of brake motor the brake is NORMALLY CLOSED NEGATIVE action When the power supply is switched off the brake is engaged The brake opens only when...

Page 16: ...phase motor with DC brake separately powered AC 1 phase with rectifier In case of brake motor the brake is NORMALLY CLOSED NEGATIVE action When the power supply is switched off the brake is engaged Th...

Page 17: ...In case of brake motor the brake is NORMALLY CLOSED NEGATIVE action When the power supply is switched off the brake is engaged The brake opens only when power is supplied the brake is wired separately...

Page 18: ...ECHANICAL AND ELECTRICAL PROTECTION MUST BE INSTALLED AND ACTIVATED TO PREVENT DAMAGE TO PERSONS OR PROPERTY Check that all plant fixing elements are well machined and cleaned and that they fit the di...

Page 19: ...not correct RIGHT WORKING OF THE ACTUATOR AND PLANT CANNOT BE GUARANTED IF SIDE OR NOT AXIAL LOAD ARE APPLIED TO THE ACTUATOR 6 8 Installation of rod end fitting elements To install a mounting element...

Page 20: ...as to be moved Measure the initial length of the actuator then run the actuator GRADUALLY from the control unit in order to reach the plant to its more distant extreme position Check continuously the...

Page 21: ...olit FLM 2 NLGI 2 Grease NLGI 1 DIN 51818 LUBCON Thermoplex ALN 1001 Also suitable FUCHS Renolit DURAPLEX EP 2 NLGI 2 AGIP Grease AC 1 NLGI 1 MOBIL Mobilgrease FM 101 NLGI 1 KLUBER Klubersynth UH1 14...