On an error, the status line shows the error message. The drive redirection software tries to lock the
local drive before it is redirected. That means that it tries to prevent the local operating system from
accessing the drive as long as it is redirected. This may also fail, especially if a file on the drive is
currently open. In the case of a locking failure, you will be prompted if you want to establish the
connection anyhow. This should not be a serious problem when the note above is respected. If the
write support is enabled, a drive which is not locked might be damaged by the Drive Redirection.
With the
Disconnect
button, a connection via Drive Redirection connection is stopped.
Exit/Hide
If the
Exit
button is pressed, the Drive Redirection software is closed. If a Drive Redirection
connection is active, the connection will be closed before the application terminates.
Using the Hide to Tray button the application is hidden, but not terminated completely. That means
that an active connection will be kept active until it is closed explicitly. You can access the software
by its tray icon. The tray icon also shows whether a connection is established or not. A double click
on the icon shows the application window, or with a right click you may access a small menu
Operation Procedures:
1. Please install Drive Redirection Software on remote computer first then run Drive
Redirection application and fill in information accordingly: