4.3.5.2 Intelligent control board
Wiring instruction:
1. Connect L and N to the power supply of AC220V/50HZ; AC110V/60HZ; L is Live
wire, N is Neutral wire, and PE is grounding wire.
2. Connect LAMP to caution light; voltage: AC220V/50HZ; AC110V/60HZ.
3. Connect the motor wire MOT2 to the REV motor wire, connect MOT1 to the FWD
motor wire, and connect MOTCOM to the motor common wire.
4. Connect MOTCAP to the capacitor wire.
J2 Terminal (For the convenience of wiring, this terminal is accompanied with
failure diagnosis light)
1. Gate close control button (N.O.)
2. Gate open control button (N.O.)
3. Stop control button (N.O.)
4. Control button common terminal
5. Open/Stop/Close/Stop loop control button (N.O.)
6. Pedestrian mode control button (N.O.)
Press the button while the door is closed, it will open for 1 meter which is for
pedestrian only.
Figure 19