background image

XLR

8

MGS524

24 Volt DC

SLIDING GATE OPENER

INSTALLATION MANUAL

For Professional Installation ONLY

For level gradient installations ONLY

Chamberlain Australia Pty Ltd

PO Box 1446

Lane Cove NSW 1595

Phone toll free: 1800 638 234

Chamberlain New Zealand Ltd

PO Box 100-221

North Shore 0745

Phone toll free: 0800 653 667

www.go-merlin.com

Summary of Contents for XLR8 MGS524

Page 1: ...Professional Installation ONLY For level gradient installations ONLY Chamberlain Australia Pty Ltd PO Box 1446 Lane Cove NSW 1595 Phone toll free 1800 638 234 Chamberlain New Zealand Ltd PO Box 100 2...

Page 2: ...ries as it closes After the installation a final test of the full function of the system and the full function of the safety devices must be done The full protection against potential squeeze or entra...

Page 3: ...oad circuit When this occurs the unit will cease operations until such time as the motor cools Gate size When calculating the gates weight allow for the gate s length a light weight long gate long 5m...

Page 4: ...t the exit point for the conduit is on the correct side of the base plate in relation to the motor The plate has two recesses ensure that the conduit exits to the rear of the motor this will facilitat...

Page 5: ...el including the start and stop limits 1 2mm clearance between drive and rack Mounting the Motor Hand tighten one of the nuts provided onto each of the four posts tighten to about 15mm from the base o...

Page 6: ...using the bolt and nylex nut provided Installing the magnet and bracket for nylon rack Identify your start and stop limit Fit the bracket over the rack and tighten the screws Install the start and st...

Page 7: ...5m 1 2 3 4 5 2 3 INSTALLATION OF CONTROL BOARD The CB202 control board was designed for installation in a special covering under the housing of the sliding gate drive The installation of the electrica...

Page 8: ...in 0 5mm Terminals The terminal blocks on the controller can be removed pull to facilitate a convenient wiring and are pushed back only while installing the controller Even if a terminal strip is not...

Page 9: ...Rolling Code feasible frequencies 433 MHz The motor control unit is a highly modern electronic unit controlled by a microprocessor It has all wiring facilities and functions required for safe operati...

Page 10: ...tor red cable 24 V 150 mA flashing light accessory Key symbol keyswitch COM negative pole PHOTO2 photocells 2 accessory PHOTO1 photocells 1 accessory COM negative pole STOP stop switch or 8 2 kOhms sa...

Page 11: ...section 0 5 mm2 or more Also see STOP 8 2kOHM under Jumper Settings ANTENNA OPTIONAL MODEL ANT4X 1LM The control board is supplied with a wire antenna as standard An external antenna accessory can be...

Page 12: ...OBSTACLE SPEED 1 SPEED 2 RADIO PHO 3 LEARN DGN LIGHT CONTACT PED COM STOP OPEN PED Model CM475 8 2 open ffnen ouvrir open open ffnen ouvrir open close schliessen fermer sluiten close schliessen fermer...

Page 13: ...ust be removed and replaced by the switch or a switch circuit OPEN PED Defines if a key switch opens the gate completely or partially FREE opens partially ca 100 150 cm PLUGGED opens completely Note I...

Page 14: ...LIM yellow limit switch OPEN should now light up and the gate can be opened as required Otherwise change the limit switch position before further settings are made 5 Close the gate with the button P1...

Page 15: ...hen slows down 1 The drive is at the limit switch CLOSED LED CLOSE LIM glows 2 Press the button P1 until the gate starts to open LED LEARN glows The automatic programme starts slow speed 3 The drive m...

Page 16: ...collecting points Batteries and rechargeable batteries are marked with a crossed waste container as well as with the chemical symbol which describes their toxic element Cd for cadmium Hg for mercury a...

Page 17: ...041ASLG 0185SA Base Housing 041ASLG 1150SA Limit Reader 041ASLG 0383SA Gear Assembly 041ASLG 1004SA Replacement Housing 041ASLG 0198 Worm Gear 041ASLG 0310SA Motor Assembly 041ASLG 0375SA 041ASLG 0353...

Page 18: ...vy or rough running B Gate blocked or rough running at a certain position C Gate not balanced D Faulty mechanical installation All Consult gate dealer specialist 6x blinking Photocells 1 block install...

Page 19: ...e gate can move in an uncontrolled dangerous manner if the gate opener has been released A stronger force is needed in the upwards direction of the slope and then in the opposite direction the gate op...

Page 20: ...aw In Australia in addition to your rights under this Chamberlain Limited Warranty our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replac...