Positioning the Chiller
Climate Class
The chiller is designed to operate within a climate class 3 environment (25°C
@ 60% RH).
Location
Select a suitable location for the chiller away from direct sunlight and heat
sources e.g. radiators, baseboard heaters, cooking appliances etc.
This chiller is intended to sit on a raised benchtop. Ensure the bench will
support the chiller which could weigh up to 120kg when fully loaded.
The front door (electronic controller side) is fitted with a door switch. Position
the chiller so that the front door opens to the customer side of the benchtop.
This enables the door switch to detect customer door openings.
Ventilation
Ensure adequate ventilation is provided around the chiller. The chiller is
designed for free-standing installation only, and should not be recessed or
enclosed in a cabinet.
Installation
Guidelines
When installing the chiller:
Remove all packaging material from the inside and outside of the chiller.
Ensure the chiller is positioned on a level surface so the doors shut and
seal correctly, and to prevent the condensate tray from overflowing.
Ensure the installation surface is capable of supporting the fully loaded
chiller.
Allow adequate space for door opening. The self-closing doors have
pre-tensioned internal torsion bars.
Do not overload the power supply (see the rating label inside the
cabinet for power supply and current draw information).
Position the front door (electronic controller side) towards the customer.
Power Cord
The chiller is fitted with a 2 metre flexible power cord with a 3-pin plug, which
exits the front of the refrigeration system.
Levelling
Adjust the four stabiliser feet (see image below) to ensure the chiller sits on
a level surface so that both doors shut and seal correctly. Turn the stabiliser
foot clockwise to raise and anti-clockwise to lower the cabinet.
Front door
Electronic
controller
IMPORTANT
Ensure the controller faces the customer side of the benchtop
Stabiliser foot