Data Pro
P/N 10029355 Rev AE
Operation Manual
Page 9 of 92
Figure
1 -
Power Supply
Figure
2 -
Power Connection
2.1 AC Power Connection
Connect a
‘Black’ wire from the Primary current protected AC-DC power source to ‘Line’ of
Connect a
‘White’ wire from the Primary current protected AC-DC power source to ‘Neutral’ of
Connect a
‘Green’ wire from the AC-DC power to the AC grounding block. Confirm ST1 - Earth Ground
and grounding block are connected to Earth Ground. See
Figure
3
– Power Switch
2.2 External DC Power Connection
1. Remove the factory connections between
J5 and J7 ports (see
Figure 2
), and the DC
2. Connect the external DC power supply
“Ground“ J7 “GND”. Keep the jumper connection between
J5 and J7 as both ports are powered from the same source.
3. Disconnect the fan connection from J1 if the external DC power supply is higher than 12VDC.
4. If available, make the
‘Earth Ground’ connection to ‘ST1 - Earth Ground’ terminal on
5. If the Data Pro has the front panel power button installed, carefully remove the power wire from the
and replace it with the “+” DC voltage from the DC power
supply. If the power button is not installed,
connect the “+” DC voltage from the DC power supply to
J7 “+” (see
Figure 2
).
AC-DC Power Supply
Line
Neutral
J5
J1
J2
J7
J3
ST1 - Earth
Ground
Remove & Replace