The FSK/FIC-1500 are shipped with default Modbus slave ID of
‘1’.
8.5.5.6 Chan Addr (Slave Addresses)
The gauges can have a Modbus address from 32 to 48.
The default gauge addresses are:
32 for Pressure/Temperature (e.g. gauge model C-4000 and QTIEG-4000)
32 for Pressure/Temperature, 33 for Vibration (e.g. C-4500)
32 for Intake Pressure/Temperature, 33 for X and Y Vibration, and 34 for Discharge
Pressure/Temperature (e.g. C-5500)
The gauge serial number will have a suffix to indicate particular sensor types:
‘D’ (Discharge)
‘I’ (Intake)
‘V’ (Vibration)
Combination of ‘D’,’V’, and ’I’
NOTE:
When connecting multiple gauges to the Data Pro, first configure each gauge
individually. The gauges connected to each FIC musthave different Modbus address.
The recommendation is not to change gauge address while the gauge is downhole. A warning
message appears on the screen for the user to acknowledge and confirm the action of
‘Gauge Address
Change’. The menu steps to change the gauge Modbus address:
Menu
Interface Setup
Interface For Gauge
Config
Chan Addr
Edit
Figure 34
– Gauge Addresses