- 30 - 

5

INSTALLATION 

安装

 

5.1

INSTALLATION SAFETY 

安装安全

 

1

Always wear dry insulation protection equipment: insulated tools, head gear, insulated gloves, safety 

belt and safety shoes (with rubber soles). 

请使用干燥的绝缘防护措施:如绝缘工具、安全帽、绝缘手套、安全带和安全鞋(橡胶底)。

 

2

Make sure flammable gasses are not generated or present near the installation site. 

请确保安装地点附近,不会有或者不会产生可燃性气体。

 

3

Do not install modules under rain, snow or windy conditions. Place disassembled PV modules correctly. 

请勿在下雨、下雪或大风的情况下安装组件,并将已拆包组件进行妥善安置。

 

4

Keep the PV module packed in the carton until installation. Please install immediately after unpacking. 

Please keep the connector dry and clean during installation to avoid the risk of electric shock. Do not perform any 
work if the terminals of PV module are wet, until they are dry. 

安装的时候再把组件拆包。请在开箱后立即安装,安装时请保持连接器干燥清洁,以免触电风险。如果光伏组

件的连接器端子潮湿则禁止安装,直至干燥后方可安装。

 

5

Please take measures to insulate during PV module installation and wiring.Do not unplug the connector 

if the system circuit is connected to a load. 

在光伏组件安装和布线期间,必须进行绝缘防护。如果系统电路与负载接通,请不要拔下连接插头。

 

6

Do not touch the junction box and the end of the interconnect cables (connectors) with bare hands during 

installation or under sunlight, regardless if the PV module is connected to or disconnected from the system. 

不管组件有没有连接到光伏系统,在安装过程或者是有光照照在组件上的时候,请不要裸手接触接线盒或者公

母接头。

 

7

During installation, if PV modules are touched by bare hands, there is a risk of scalding or electric shock. 

在安装过程中,避免裸手触摸组件,会有烫伤或者电击的危险。

 

8

Do not hit or put excessive load on the front or back of PV modules, this may break the cells or cause 

microcracks. 

不要在组件的正面或背面放过重的物体或者进行撞击,这可能会损坏电池片或者造成电池片隐裂。

 

9

Make sure that the polarity of each module or a string is not reversed considering the rest of the modules 

or strings.  

考虑到其他模块或串,请确保每个模块或串的极性没有颠倒。

 

10

Do not stand on the module glass. There is a risk of injury or electric shock if glass is broken.Do not 

work alone (always work as a team of 2 or more people). 

不要站在玻璃上,以免玻璃破碎造成伤害或引发触电危险。不要单独工作(一直保持由

2

个或更多的人组成团

队工作)

 

11

Ensure sure that all connections are securely made with no gap between the contacts. Any gap can 

result in electrical arcing that can cause a fire hazard and/or an electric shock.  

确保所有连接牢固,触点之间无缝隙。任何缝隙都可能导致电弧,从而导致火灾和

/

或触电危险。

 

12

Do not damage the back sheet of PV modules when fastening the PV modules to a support with bolts. 

在通过螺栓将光伏组件紧固到支架上时,不要损坏光伏组件的背板。

 

13

Do not drill holes in the frame. It may cause corrosion of the frame or PV modules burst. 

不要擅自在组件的边框上进行钻孔,可能会引起边框腐蚀以及组件爆裂。

 

14

Do not damage the surrounding PV modules or mounting structure when replacing a PV module. 

更换光伏组件时,不要损坏周围的光伏组件或安装结构。

 

15

Cables should be fixed in the area not exposed to direct sunlight to prevent cables aging. 

电缆应固定在不受阳光直射区域,防止电缆老化。

 

16

Protective measures must be taken in the process of installation to avoid force extrusion or impact on 

Summary of Contents for SRP 6MA Series

Page 1: ...Name SERAPHIM SOLAR SYSTEM CO LTD 1 2 Add No 1 2 Hengyao Road Henglin Town Wujin District Changzhou City P R China Installation Guide for SERAPHIM photovoltaic module 2021 V3 3...

Page 2: ...TY 3 3 UNLOAD TRANSPROTATION STORAGE 4 3 1 MAKERS ON OUTER PACKAGING 5 3 2 UNLOADING WARNNING 6 3 3 SECONDARY TRANSPORT AND WARNING 7 3 4 STORAGE 8 4 UNPACKING SAFETY 28 5 1 INSTALLATION SAFETY 30 5 2...

Page 3: ...ite at https www hg energy group com as these lists are updated on a regular basis https www seraphim energy cn 2 In the event of any inconsistency among different language versions of this document t...

Page 4: ...onal electrical standards 2 Seraphim recommends that PV module installation is conducted by personnel who have been professionally trained in PV system installation Operation by personnel who are not...

Page 5: ...id such as water to extinguish the fire 5 Do not install or handle modules when they are wet or during periods of high wind 6 At the installation site take care to keep modules and in particular their...

Page 6: ...more people with nonslip gloves and both hands 2 6 Do not lift modules by their wires or junction box 7 Do not handle the modules over head or stack the modules 8 Do not place excessive loads on the m...

Page 7: ...lled modules must be kept dry not expose to rain or moisture 3 1 3 Modules in carton are fragile which must be handled with care 3 1 4 The packaging must be transported upright 3 1 5 Do not step on th...

Page 8: ...Two people shall support at the two sides of the righting carton gently to place it on the relatively flat position of the project site 2 3 2 2 Use a forklift to remove the module pallets from the tr...

Page 9: ...tion make sure that the package is fixed securely to the shipping platform without movement Do not Stack more than two layers on truck 2 3 3 3 Only one layer stacking is only allowed for transport at...

Page 10: ...amage or collapse of the modules caused by moisture in the packaging 5 If pallets are stored temporarily outside then place a protective covering over the pallet to protect it from direct weathering a...

Page 11: ...65 9 7 9 77 9 83 9 88 Open Circuit Voltage Voc 48 6 2 48 8 2 49 1 2 49 4 2 49 7 2 49 9 2 50 1 2 Short Circuit Current Isc 9 8 4 9 88 4 9 93 4 9 98 4 10 05 4 10 11 4 10 16 4 Maximum Series Fuse 25 25 2...

Page 12: ...96 4 9 03 4 9 12 4 9 20 4 Maximum Series Fuse 20 20 20 20 20 20 20 20 Rated Power Pmp 340 345 350 Power Sorting 0 4 99W 0 4 99W 0 4 99W Power Tolerance 3 3 3 Maximum Power Voltage Vmp 37 9 38 1 38 3...

Page 13: ...10 36 10 44 10 52 10 60 10 68 10 76 Open Circuit Voltage Voc 43 9 2 44 10 2 44 20 2 44 30 2 44 50 2 44 70 2 44 9 2 45 10 2 Short Circuit Current Isc 10 73 4 10 82 4 10 91 4 10 99 4 11 08 4 11 17 4 11...

Page 14: ...it Current Isc 9 65 4 9 73 4 Maximum Series Fuse 25 25 SRP XXX E11A HV SRP XXX E11A XXX 340 380 Electrical Characteristics Rated Power Pmp 340 345 350 355 360 365 370 375 Power Sorting 0 4 99W 0 4 99W...

Page 15: ...30 335 340 345 350 355 360 365 Power Sorting 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W Power Tolerance 3 3 3 3 3 3 3 3 Maximum Power Voltage Vmp 37 8 38 1 38 4 38 7 39 39 3 39 6...

Page 16: ...wer Voltage Vmp 41 8 42 0 40 78 41 03 41 29 41 55 41 81 42 05 Maximum Power Current Imp 10 77 10 84 12 88 12 92 12 96 13 13 04 13 08 Open Circuit Voltage Voc 50 10 2 50 30 2 49 02 2 49 33 2 49 4 2 49...

Page 17: ...40 445 450 Power Sorting 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W Power Tolerance 3 3 3 3 3 3 3 3 Maximum Power Voltage Vmp 34 34 2 34 4 34 6 34 8 34 08 34 18 34 28 Maximum Powe...

Page 18: ...urrent Imp 9 22 9 28 9 36 9 42 9 52 9 71 9 8 9 9 Open Circuit Voltage Voc 43 8 2 44 1 2 44 3 2 44 6 2 44 7 2 44 5 2 44 7 2 44 9 2 Short Circuit Current Isc 9 69 4 9 75 4 9 83 4 9 89 4 10 4 10 21 4 10...

Page 19: ...ies Fuse 20 20 20 20 20 20 20 20 Rated Power Pmp 350 355 Power Sorting 0 4 99W 0 4 99W Power Tolerance 3 3 Maximum Power Voltage Vmp 39 3 39 6 Maximum Power Current Imp 8 91 8 97 Open Circuit Voltage...

Page 20: ...35 6 Maximum Power Current Imp 8 26 8 36 8 44 8 53 8 60 8 69 8 76 8 85 Open Circuit Voltage Voc 40 7 2 40 9 2 41 2 2 41 4 2 41 7 2 41 9 2 42 2 2 42 4 2 Short Circuit Current Isc 8 80 4 8 89 4 8 97 4 9...

Page 21: ...W 0 4 99W 0 4 99W 0 4 99W 0 4 99W Power Tolerance 3 3 3 3 3 3 3 Maximum Power Voltage Vmp 32 4 32 6 32 8 33 0 33 2 33 4 33 6 Maximum Power Current Imp 9 11 9 21 9 30 9 40 9 49 9 58 9 68 Open Circuit V...

Page 22: ...5 25 25 25 25 25 25 25 SRP xxx 6PA DG xxx 315 340 Electrical Characteristics Rated Power Pmp 315 320 325 330 335 340 Power Sorting 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W Power Tolerance 3 3 3...

Page 23: ...e Voc 49 1 2 49 3 2 49 5 2 49 7 2 49 9 2 48 7 2 48 9 2 49 2 2 Short Circuit Current Isc 9 96 4 10 04 4 10 12 4 10 19 4 10 26 4 10 9 4 10 97 4 11 04 4 Maximum Series Fuse 25 25 25 25 25 25 25 25 SRP xx...

Page 24: ...5 2 46 7 2 46 9 2 Short Circuit Current Isc 8 80 4 8 89 4 8 95 4 9 04 4 9 11 4 9 19 4 9 27 4 Maximum Series Fuse 20 20 20 20 20 20 20 SRP xxx BPB DG xxx 265 285 Electrical Characteristics Rated Power...

Page 25: ...09 4 10 16 4 10 25 4 10 32 4 10 40 4 10 55 4 10 97 4 11 04 4 Maximum Series Fuse 25 25 25 25 25 25 25 25 Rated Power Pmp 430 435 440 445 450 525 530 535 Power Sorting 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0...

Page 26: ...Maximum Power Voltage Vmp 34 7 35 35 2 33 6 33 8 34 34 2 34 4 Maximum Power Current Imp 9 52 9 58 9 66 10 27 10 36 10 45 10 53 10 62 Open Circuit Voltage Voc 41 1 2 41 4 2 41 6 2 40 6 2 40 8 2 41 2 4...

Page 27: ...9 194 9 284 9 364 9 454 Maximum Series Fuse 25 25 25 25 25 25 25 25 Rated Power Pmp 360 365 370 375 485 490 495 500 Power Sorting 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W Power...

Page 28: ...d Power Pmp 425 430 435 440 445 450 Power Sorting 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W Power Tolerance 3 3 3 3 3 3 Maximum Power Voltage Vmp 43 8 43 9 44 1 44 3 44 4 44 6 Maximum Power Curr...

Page 29: ...d Power Pmp 545 Power Sorting 0 4 99W Power Tolerance 3 Maximum Power Voltage Vmp 31 99 Maximum Power Current Imp 17 04 Open Circuit Voltage Voc 39 30 2 Short Circuit Current Isc 17 99 4 Maximum Serie...

Page 30: ...2201104400002 DM6772201104400012 BM6604201102800003 DM6772201104400002 DM6772201104400012 BM6604201102800003 DM6772201104400003 DM6772201104400013 BM6604201102800004 DM6772201104400003 DM6772201104400...

Page 31: ...is required to be level to ensure that the package can be placed stably avoiding sliding 5 Wear protective gloves during unpacking to avoid hand injury and fingerprints on the glass surface 6 Each mo...

Page 32: ...cted from the system 7 During installation if PV modules are touched by bare hands there is a risk of scalding or electric shock 8 Do not hit or put excessive load on the front or back of PV modules t...

Page 33: ...er than 1500Vdc This maximum voltage should not be exceeded at any time and as the voltage of the module increases above data sheet values at operating temperatures below 25 C then these need to be ta...

Page 34: ...emisphere the PV modules should typically face north When selecting the installation location avoid areas with trees buildings or obstacles because these objects will form shadows on Solar PV modules...

Page 35: ...landscape and portrait orientation however the impact of dirt shading the solar cells can be minimized by orienting the product in portrait Sunpro Power Avoid using a mounting method that will block t...

Page 36: ...on guides or consult a reputable Solar installer or systems integrator Dust building up on the surface of the modules can impair module performance YuHuan Sunpro Solar recommends installing the module...

Page 37: ...om building chimney and tree etc and even the partially shading such as the dirt snow and aerial wire etc should be avoided The generation gain is related to the ground reflectivity the module install...

Page 38: ...n approved by Seraphim the modules will not continue to carry a valid warranty Modules shall not be subjected to wind or snow loads which is exceeding the maximum permissible designed loads and shall...

Page 39: ...on install maintenance and safety Seraphim will not supply the related material for system installation 1 Screw Installation Each PV module has 8 mounting holes shown as drawing 1 The downward mechani...

Page 40: ...tand a downward force of up to 5400 Pa 550 kg m2 or 2400 Pa 244 kg m2 according to where they are clamped Site specific loads such as wind or snow which may exert forces in a different way need to be...

Page 41: ...Type 11 Type 12 Type 13 SRP XXX BPZ SRP XXX BPZ HV SRP XXX BMZ SRP XXX BMZ HV SRP XXX BMZ TB SRP XXX 6PA SRP XXX 6PA HV SRP XXX 6MA SRP XXX 6MA HV SRP XXX 6PB SRP XXX 6PB HV SRP XXX 6MB SRP XXX 6MB HV...

Page 42: ...5400 180 480 5400 50 480 2400 1776 1755 1052 1038 50mm 200 500 5400 1916 1890 1909 1134 1133 1134 50mm 250 550 5400 200 500 5400 50 500 2400 2102 2073 2093 1134 1133 1134 50mm 270 570 5400 280 580 540...

Page 43: ...e to the series of PV modules as listed below Table 2 The selection and installation of the clamps shall obey the requirement according to table 3 Otherwise the module may not satisfy the mechanical l...

Page 44: ...42 Type Load Pa Clamp Length Installation Drawing Type1 150mm Type2 200mm 2400 2400 2400 2400 Type3 150mm Type4 200mm 2400 2400 2400 2400 Type5 2400 2400 200mm...

Page 45: ...able to the series of PV modules as listed below Table 2 The selection and installation of the clamps shall obey the requirement according to table 3 Otherwise the module may not satisfy the mechanica...

Page 46: ...44 Table 3 Type Load Pa Clamp Length Installation Drawing Type1 50mm Type2 50mm 5400 2400 5400 2400 Type3 50mm Type4 50mm 5400 2400 5400 2400 Type5 50mm 5400 2400...

Page 47: ...sed However failure to comply with the above recommendations will result in a lowering of the load handling capabilities below the empirical value and product failure as a result of an overload situat...

Page 48: ...2 Fig 3 Split J Box at module middle position for horizontal direction 3 Precautions To minimize risk in the event of an indirect lightning strike avoid forming loops when designing the system In orde...

Page 49: ...modules cannot be connected in series Modules connected in series should ensure the consistency of their current The voltage of the module string should not exceed the allowable system voltage value...

Page 50: ...the devices used in the system The modules must not be connected together to create a voltage that is higher than the permitted system voltage Product can be irreparably damaged if an array string is...

Page 51: ...DC electricity whenever light falls on it similarly the inverter automatically turns ON as soon as there is sufficient energy from the solar array to efficiently convert this into grid quality AC powe...

Page 52: ...tions must be followed to meet Seraphim warranty conditions 3 Bypass secondary If PV module part by shadow block which can lead to reverse voltage related to Solar cells PV modules in other unaffected...

Page 53: ...r of strings in parallel Parallel module configurations fuse rating Isc Isc 5 Grounding All PV module frames and mounting brackets must be properly grounded in accordance with the applicable national...

Page 54: ...1 Grounding by unused mounting holes 2 Other professional grounding devices The electrical contact points of all the above grounding methods should penetrate the anodized film of the aluminum frame PV...

Page 55: ...s grade and adequate ventilation should be provided between the backplane and the mounting surface Different roof structure and installation will affect the fire safety performance of the building If...

Page 56: ...to prevent electric shock Exposure of PV modules to sunlight will generate high voltages this is dangerous Please pay attention to safety when maintenance and it must be done by professionals Wear cut...

Page 57: ...put and may cause hot spots So the surface of PV modules should be kept clean Maintenance work should be performed at least once six months or frequently Warning It should be carried out by trained pe...

Page 58: ...back surface of the module normally does not need to be cleaned but in the event this is deemed necessary avoid the use of any sharp projects that might damage the penetrating the substrate material W...

Page 59: ...TROUBLESHOOTING If the PV system does not work properly please inform your installer immediately It is recommended to perform a preventive inspection every six months please don t change any modules...

Reviews: