- 56 - 

together with a mild detergent and clean water. Take care to avoid severe thermal shocks which might damage the 
module by cleaning modules with water which has a similar temperature to the modules being cleaned. For example, 
do not use cold water to clean the module when the temperature of it is high during the day, otherwise there will be 
the risk of module damage. 

应在辐照度低于

200W/m

2

的情况下清洁光伏组件。清洁组件时,应使用软布和温和的清洁剂以及清水。清洁组

件时应保证水与组件之间的温差不大,以注意避免出现严重的可能损坏组件的热冲击。比如不在一天中光伏组件温
度较高的时候使用冷水清洗,以防损坏光伏组件。

 

It is forbidden to clean PV modules under the weather conditions of wind more than 4 grades, heavy rain or 

heavy snow. 

严禁在风力大于

4

级、大雨或大雪的气象条件下清洗光伏组件。

 

When cleaning PV modules, Do not step on the modules; Do not spray water on the backside of the module or 

the cables; keep the connectors clean and dry; prevent fire and electrical shock from occurring; Do not use as steam 
cleaner. 

光伏组件清洁工作中,严禁踩踏组件、严禁流水溅射至组件背面和电缆,严禁清洁组件背面,要保证连接头的

清洁和干燥,防止电击和火灾危险;严禁使用蒸汽清洁器。

 

The  back  surface  of  the  module  normally  does  not  need  to  be  cleaned  but,  in  the  event  this  is  deemed 

necessary, avoid the use of any sharp projects that might damage the penetrating the substrate material. 

组件的后表面通常不需要清洁;但在认为确实有必要对其进行清洗时,应避免使用可能引起损坏或穿透基底材

料的一切尖锐物体。

 

When cleaning the back surface of the module, take care to avoid penetrating the substrate material. Modules 

that are mounted flat (0° tilt angle) should be cleaned more often, as they will NOT ''self-clean'' as effectively as 
modules mounted at a 10° tilt or greater. 

清洁组件的背面时,注意避免清洗液渗到材料底层。应稍微频繁地清洁水平安装的组件(

倾斜角),

 

因为这

些组件不会像以

10°

倾斜角或更大倾斜角安装的组件那样具有

自清洁

功能。

 

Do not scrape or grind stains off surfaces while PV modules are dry, as this can cause minor scratches on the 

surface. 

组件干燥的情况下不要在表面将污渍刮掉或者磨掉,因为这样会在表面引起细小的刮伤。

 

Water requirements when cleaning: 

清洗时对水质的要求:

 

1

PH: 5

7

 

PH

:5~7 

2

Chloride or salt content: 0 - 3000 mg/L 

氯化物或盐分含量:

0

3000 mg/L

 

3

Turbidity: 0-30 NTU 

浑浊度:

0

30 NTU

 

4

Conductivity: 1500

3000 μs/cm 

电导率:

1500

3000 μs/cm

 

5

Total dissolved solids: ≤1000 mg/L 

总溶解固体:

≤1000 mg/L

 

6

Water hardness: 0-40 mg/L 

水硬度:

0

40 mg/L

 

7

Non-alkaline water must be used, and softened water can be used when conditions permitted. 

必须采用非碱性水,具备条件时应使用软化水。

 

Summary of Contents for SRP 6MA Series

Page 1: ...Name SERAPHIM SOLAR SYSTEM CO LTD 1 2 Add No 1 2 Hengyao Road Henglin Town Wujin District Changzhou City P R China Installation Guide for SERAPHIM photovoltaic module 2021 V3 3...

Page 2: ...TY 3 3 UNLOAD TRANSPROTATION STORAGE 4 3 1 MAKERS ON OUTER PACKAGING 5 3 2 UNLOADING WARNNING 6 3 3 SECONDARY TRANSPORT AND WARNING 7 3 4 STORAGE 8 4 UNPACKING SAFETY 28 5 1 INSTALLATION SAFETY 30 5 2...

Page 3: ...ite at https www hg energy group com as these lists are updated on a regular basis https www seraphim energy cn 2 In the event of any inconsistency among different language versions of this document t...

Page 4: ...onal electrical standards 2 Seraphim recommends that PV module installation is conducted by personnel who have been professionally trained in PV system installation Operation by personnel who are not...

Page 5: ...id such as water to extinguish the fire 5 Do not install or handle modules when they are wet or during periods of high wind 6 At the installation site take care to keep modules and in particular their...

Page 6: ...more people with nonslip gloves and both hands 2 6 Do not lift modules by their wires or junction box 7 Do not handle the modules over head or stack the modules 8 Do not place excessive loads on the m...

Page 7: ...lled modules must be kept dry not expose to rain or moisture 3 1 3 Modules in carton are fragile which must be handled with care 3 1 4 The packaging must be transported upright 3 1 5 Do not step on th...

Page 8: ...Two people shall support at the two sides of the righting carton gently to place it on the relatively flat position of the project site 2 3 2 2 Use a forklift to remove the module pallets from the tr...

Page 9: ...tion make sure that the package is fixed securely to the shipping platform without movement Do not Stack more than two layers on truck 2 3 3 3 Only one layer stacking is only allowed for transport at...

Page 10: ...amage or collapse of the modules caused by moisture in the packaging 5 If pallets are stored temporarily outside then place a protective covering over the pallet to protect it from direct weathering a...

Page 11: ...65 9 7 9 77 9 83 9 88 Open Circuit Voltage Voc 48 6 2 48 8 2 49 1 2 49 4 2 49 7 2 49 9 2 50 1 2 Short Circuit Current Isc 9 8 4 9 88 4 9 93 4 9 98 4 10 05 4 10 11 4 10 16 4 Maximum Series Fuse 25 25 2...

Page 12: ...96 4 9 03 4 9 12 4 9 20 4 Maximum Series Fuse 20 20 20 20 20 20 20 20 Rated Power Pmp 340 345 350 Power Sorting 0 4 99W 0 4 99W 0 4 99W Power Tolerance 3 3 3 Maximum Power Voltage Vmp 37 9 38 1 38 3...

Page 13: ...10 36 10 44 10 52 10 60 10 68 10 76 Open Circuit Voltage Voc 43 9 2 44 10 2 44 20 2 44 30 2 44 50 2 44 70 2 44 9 2 45 10 2 Short Circuit Current Isc 10 73 4 10 82 4 10 91 4 10 99 4 11 08 4 11 17 4 11...

Page 14: ...it Current Isc 9 65 4 9 73 4 Maximum Series Fuse 25 25 SRP XXX E11A HV SRP XXX E11A XXX 340 380 Electrical Characteristics Rated Power Pmp 340 345 350 355 360 365 370 375 Power Sorting 0 4 99W 0 4 99W...

Page 15: ...30 335 340 345 350 355 360 365 Power Sorting 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W Power Tolerance 3 3 3 3 3 3 3 3 Maximum Power Voltage Vmp 37 8 38 1 38 4 38 7 39 39 3 39 6...

Page 16: ...wer Voltage Vmp 41 8 42 0 40 78 41 03 41 29 41 55 41 81 42 05 Maximum Power Current Imp 10 77 10 84 12 88 12 92 12 96 13 13 04 13 08 Open Circuit Voltage Voc 50 10 2 50 30 2 49 02 2 49 33 2 49 4 2 49...

Page 17: ...40 445 450 Power Sorting 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W Power Tolerance 3 3 3 3 3 3 3 3 Maximum Power Voltage Vmp 34 34 2 34 4 34 6 34 8 34 08 34 18 34 28 Maximum Powe...

Page 18: ...urrent Imp 9 22 9 28 9 36 9 42 9 52 9 71 9 8 9 9 Open Circuit Voltage Voc 43 8 2 44 1 2 44 3 2 44 6 2 44 7 2 44 5 2 44 7 2 44 9 2 Short Circuit Current Isc 9 69 4 9 75 4 9 83 4 9 89 4 10 4 10 21 4 10...

Page 19: ...ies Fuse 20 20 20 20 20 20 20 20 Rated Power Pmp 350 355 Power Sorting 0 4 99W 0 4 99W Power Tolerance 3 3 Maximum Power Voltage Vmp 39 3 39 6 Maximum Power Current Imp 8 91 8 97 Open Circuit Voltage...

Page 20: ...35 6 Maximum Power Current Imp 8 26 8 36 8 44 8 53 8 60 8 69 8 76 8 85 Open Circuit Voltage Voc 40 7 2 40 9 2 41 2 2 41 4 2 41 7 2 41 9 2 42 2 2 42 4 2 Short Circuit Current Isc 8 80 4 8 89 4 8 97 4 9...

Page 21: ...W 0 4 99W 0 4 99W 0 4 99W 0 4 99W Power Tolerance 3 3 3 3 3 3 3 Maximum Power Voltage Vmp 32 4 32 6 32 8 33 0 33 2 33 4 33 6 Maximum Power Current Imp 9 11 9 21 9 30 9 40 9 49 9 58 9 68 Open Circuit V...

Page 22: ...5 25 25 25 25 25 25 25 SRP xxx 6PA DG xxx 315 340 Electrical Characteristics Rated Power Pmp 315 320 325 330 335 340 Power Sorting 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W Power Tolerance 3 3 3...

Page 23: ...e Voc 49 1 2 49 3 2 49 5 2 49 7 2 49 9 2 48 7 2 48 9 2 49 2 2 Short Circuit Current Isc 9 96 4 10 04 4 10 12 4 10 19 4 10 26 4 10 9 4 10 97 4 11 04 4 Maximum Series Fuse 25 25 25 25 25 25 25 25 SRP xx...

Page 24: ...5 2 46 7 2 46 9 2 Short Circuit Current Isc 8 80 4 8 89 4 8 95 4 9 04 4 9 11 4 9 19 4 9 27 4 Maximum Series Fuse 20 20 20 20 20 20 20 SRP xxx BPB DG xxx 265 285 Electrical Characteristics Rated Power...

Page 25: ...09 4 10 16 4 10 25 4 10 32 4 10 40 4 10 55 4 10 97 4 11 04 4 Maximum Series Fuse 25 25 25 25 25 25 25 25 Rated Power Pmp 430 435 440 445 450 525 530 535 Power Sorting 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0...

Page 26: ...Maximum Power Voltage Vmp 34 7 35 35 2 33 6 33 8 34 34 2 34 4 Maximum Power Current Imp 9 52 9 58 9 66 10 27 10 36 10 45 10 53 10 62 Open Circuit Voltage Voc 41 1 2 41 4 2 41 6 2 40 6 2 40 8 2 41 2 4...

Page 27: ...9 194 9 284 9 364 9 454 Maximum Series Fuse 25 25 25 25 25 25 25 25 Rated Power Pmp 360 365 370 375 485 490 495 500 Power Sorting 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W Power...

Page 28: ...d Power Pmp 425 430 435 440 445 450 Power Sorting 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W 0 4 99W Power Tolerance 3 3 3 3 3 3 Maximum Power Voltage Vmp 43 8 43 9 44 1 44 3 44 4 44 6 Maximum Power Curr...

Page 29: ...d Power Pmp 545 Power Sorting 0 4 99W Power Tolerance 3 Maximum Power Voltage Vmp 31 99 Maximum Power Current Imp 17 04 Open Circuit Voltage Voc 39 30 2 Short Circuit Current Isc 17 99 4 Maximum Serie...

Page 30: ...2201104400002 DM6772201104400012 BM6604201102800003 DM6772201104400002 DM6772201104400012 BM6604201102800003 DM6772201104400003 DM6772201104400013 BM6604201102800004 DM6772201104400003 DM6772201104400...

Page 31: ...is required to be level to ensure that the package can be placed stably avoiding sliding 5 Wear protective gloves during unpacking to avoid hand injury and fingerprints on the glass surface 6 Each mo...

Page 32: ...cted from the system 7 During installation if PV modules are touched by bare hands there is a risk of scalding or electric shock 8 Do not hit or put excessive load on the front or back of PV modules t...

Page 33: ...er than 1500Vdc This maximum voltage should not be exceeded at any time and as the voltage of the module increases above data sheet values at operating temperatures below 25 C then these need to be ta...

Page 34: ...emisphere the PV modules should typically face north When selecting the installation location avoid areas with trees buildings or obstacles because these objects will form shadows on Solar PV modules...

Page 35: ...landscape and portrait orientation however the impact of dirt shading the solar cells can be minimized by orienting the product in portrait Sunpro Power Avoid using a mounting method that will block t...

Page 36: ...on guides or consult a reputable Solar installer or systems integrator Dust building up on the surface of the modules can impair module performance YuHuan Sunpro Solar recommends installing the module...

Page 37: ...om building chimney and tree etc and even the partially shading such as the dirt snow and aerial wire etc should be avoided The generation gain is related to the ground reflectivity the module install...

Page 38: ...n approved by Seraphim the modules will not continue to carry a valid warranty Modules shall not be subjected to wind or snow loads which is exceeding the maximum permissible designed loads and shall...

Page 39: ...on install maintenance and safety Seraphim will not supply the related material for system installation 1 Screw Installation Each PV module has 8 mounting holes shown as drawing 1 The downward mechani...

Page 40: ...tand a downward force of up to 5400 Pa 550 kg m2 or 2400 Pa 244 kg m2 according to where they are clamped Site specific loads such as wind or snow which may exert forces in a different way need to be...

Page 41: ...Type 11 Type 12 Type 13 SRP XXX BPZ SRP XXX BPZ HV SRP XXX BMZ SRP XXX BMZ HV SRP XXX BMZ TB SRP XXX 6PA SRP XXX 6PA HV SRP XXX 6MA SRP XXX 6MA HV SRP XXX 6PB SRP XXX 6PB HV SRP XXX 6MB SRP XXX 6MB HV...

Page 42: ...5400 180 480 5400 50 480 2400 1776 1755 1052 1038 50mm 200 500 5400 1916 1890 1909 1134 1133 1134 50mm 250 550 5400 200 500 5400 50 500 2400 2102 2073 2093 1134 1133 1134 50mm 270 570 5400 280 580 540...

Page 43: ...e to the series of PV modules as listed below Table 2 The selection and installation of the clamps shall obey the requirement according to table 3 Otherwise the module may not satisfy the mechanical l...

Page 44: ...42 Type Load Pa Clamp Length Installation Drawing Type1 150mm Type2 200mm 2400 2400 2400 2400 Type3 150mm Type4 200mm 2400 2400 2400 2400 Type5 2400 2400 200mm...

Page 45: ...able to the series of PV modules as listed below Table 2 The selection and installation of the clamps shall obey the requirement according to table 3 Otherwise the module may not satisfy the mechanica...

Page 46: ...44 Table 3 Type Load Pa Clamp Length Installation Drawing Type1 50mm Type2 50mm 5400 2400 5400 2400 Type3 50mm Type4 50mm 5400 2400 5400 2400 Type5 50mm 5400 2400...

Page 47: ...sed However failure to comply with the above recommendations will result in a lowering of the load handling capabilities below the empirical value and product failure as a result of an overload situat...

Page 48: ...2 Fig 3 Split J Box at module middle position for horizontal direction 3 Precautions To minimize risk in the event of an indirect lightning strike avoid forming loops when designing the system In orde...

Page 49: ...modules cannot be connected in series Modules connected in series should ensure the consistency of their current The voltage of the module string should not exceed the allowable system voltage value...

Page 50: ...the devices used in the system The modules must not be connected together to create a voltage that is higher than the permitted system voltage Product can be irreparably damaged if an array string is...

Page 51: ...DC electricity whenever light falls on it similarly the inverter automatically turns ON as soon as there is sufficient energy from the solar array to efficiently convert this into grid quality AC powe...

Page 52: ...tions must be followed to meet Seraphim warranty conditions 3 Bypass secondary If PV module part by shadow block which can lead to reverse voltage related to Solar cells PV modules in other unaffected...

Page 53: ...r of strings in parallel Parallel module configurations fuse rating Isc Isc 5 Grounding All PV module frames and mounting brackets must be properly grounded in accordance with the applicable national...

Page 54: ...1 Grounding by unused mounting holes 2 Other professional grounding devices The electrical contact points of all the above grounding methods should penetrate the anodized film of the aluminum frame PV...

Page 55: ...s grade and adequate ventilation should be provided between the backplane and the mounting surface Different roof structure and installation will affect the fire safety performance of the building If...

Page 56: ...to prevent electric shock Exposure of PV modules to sunlight will generate high voltages this is dangerous Please pay attention to safety when maintenance and it must be done by professionals Wear cut...

Page 57: ...put and may cause hot spots So the surface of PV modules should be kept clean Maintenance work should be performed at least once six months or frequently Warning It should be carried out by trained pe...

Page 58: ...back surface of the module normally does not need to be cleaned but in the event this is deemed necessary avoid the use of any sharp projects that might damage the penetrating the substrate material W...

Page 59: ...TROUBLESHOOTING If the PV system does not work properly please inform your installer immediately It is recommended to perform a preventive inspection every six months please don t change any modules...

Reviews: