background image

INSTALLATION OF THE CR/41/24 CONTROL UNIT

Position the appliance in proximity of the gate in a way to reduce the length of the connection cable, to the rest of 
the system, to a minimum.
For greater protection from atmospheric agents it is recommended to position the control unit under a roof or, even 
better, in a room that has two lateral walls. It is also good practice to install the appliance at a height above 1.5 m, 
where possible, in order to prevent it being tampered with by children.

WHERE TO POSITION THE CONTROL UNIT

The control unit leaves the factory with the lid positioned to open from the left side.
If you wish to open the lid from the opposite side, proceed as follows:

ATTENTION: This operation must be carried out 
before fixing the container to the wall.

Insert a flat tip screwdriver into the fixing recess of the hinges 
positioned on the rear of the base and lever on the attachment 
notch of the hinge itself; pull the lid at the same time. (see 
Fig.1)

Fig.1

Insert a flat tip screwdriver into the fixing recess of the hinge 
positioned on the front part of the lid and lever on the notched 
attachment of the hinge itself; pull the hinge at the same time. 
(see Fig.2)

Fig.2

DA

L  

19

65

Re-mount the hinges on the right side of the base by 
inserting them in the relevant seats with the attachment 
notch facing towards the inside of the container until the 
attachment clicks (see Fig.3)

Fig.3

LID SET-UP FOR LID OPENING TO THE RIGHT

!

Page 2/12

C

R

/4

1

/2

4

 I

 E

Summary of Contents for CR/41/24

Page 1: ...hibits the realisation of these types of plants by unqualified staff On realisation of its own products SERAI has respected the following Reference Directives for CE marking machinery 2006 42 EEC low...

Page 2: ...en the lid from the opposite side proceed as follows ATTENTION This operation must be carried out before fixing the container to the wall Insert a flat tip screwdriver into the fixing recess of the hi...

Page 3: ...le to the rest of the system to a minimum The control unit must be fixed via the cable passage holes facing downwards NO NO YES 6 8 mm Recommendations for connections in general rooms 1 Upstream from...

Page 4: ...meter at maximum the amperometric control is excluded RALL POTENTIOMETER speed regulation during the slowing phase with the potentiometer at maximum slowing is excluded VELOC POTENTIOMETER regulation...

Page 5: ...ontrol for electric lock SERAI M 83 1 With SW2dip2 ON control with the gate open indicator light function Input for the connection of the antenna for the built in receiver 33 BRAIDING EARTH 34 ANTENNA...

Page 6: ...ter ATTENTION in this case there may be difficulties on start up if the force is regulated low 1 2 3 ON 4 1 2 3 ON 4 1 2 3 ON 4 1 2 3 ON 4 CLAMPS 11 12 FUNCTIONING MODE Open gate indicator light outpu...

Page 7: ...essary to terminate the wing run with a certain approximation always slowing in the programmed point ATTENTION The lack of power supply to the circuit board network or battery causes the loss of the m...

Page 8: ...key P2 WORK down until M1 starts When Motor M1 should start slowing we recommend at least 50cm before the stop press key P2 WORK The motor M1 slows down ATTENTION skip this point if slowing has been e...

Page 9: ...s is set by regulating the AMP potentiometer The intervention of the amperometric control can be more or less rapid depending on the sensitivity set with the SW3 jumper The gate inverts movement for a...

Page 10: ...2 OG 04 as pedestrian control the others do not have to be memorised OG 02 and OG 04 just set the micro switches in the same sequence as that memorised LEARNING START CODE With the control unit powere...

Page 11: ...ALL AMP ON 1 2 4 3 SW1 ON 1 2 4 3 SW2 25 26 F2 F2 F3 F3 F1 F1 F4 F4 SW3 LED DL6 DL1 PED DL2 START DL3 STOP DL4 FOTO DL5 FOTOAP DL7 COSTA PAUSA LAVORO PROGR BATTERY Power supply transformer 230 20 Vac...

Page 12: ...ntiometer regulates the amperometeric control intervention which intervenes every time that the gate stops moving for a brief period of time due to external factors such as gusts of wind for example T...

Reviews: