BATTERY HOUSING AND CABLES INLET

Seats for fairleads PG11 and PG 13,5 which are easy to break through, are envisioned in the lower part of the 
container for the passage of input cables

!

ATTENTION: Close all inputs well to 
prevent the entry of insects, which 
may damage the control unit.

Two strips are supplied complete with screws for fixing the two 12V 2 Ah batteries (SERAI BT/15 or BT/20) onto the 
lid of the container

!

ATTENTION: Considering the weight 
of the batteries, it is recommended 
to install them at the end of 
mounting, before closing the box.

OPENING AND CLOSING THE BOX

When opening the box, make sure that most of the hinges 
escape from the guide on the bottom of the control unit in order 
to guarantee that the lid remains open without obstructing the 
control unit wiring operations.

In the closing phase, accompany the lid “especially in the 
presence of the battery” until complete return of the hinges. Pay 
attention that the gasket is inserted correctly. Close the lid using 
the appropriate screws.

FIXING THE CONTROL UNIT TO THE WALL

It is recommended to position the appliance in proximity 
of the gate in a way to reduce the length of the 
connection cable, to the rest of the system, to a minimum.
The control unit must be fixed via the cable passage 
holes facing downwards.

NO

NO

YES

Ø 6 ÷ 8 mm

Recommendations for connections in general rooms 

1. Upstream from the system, prepare an omnipolar isolating switch with distance of 3 mm or more between the 

contacts. As an alternative, use a 10A magnet circuit breaker switch.

2. Make any type of connections always with the system not powered, i.e. with the isolating switch in the "open" 

position ("0" symbol). In particular, the control unit must never be powered during wiring or while any expansion 
cards are being inserted.

3. When installing the plant, use the following cables: 

2

- for the power supplies to the motors: 

minimum 2.5 mm

 

2

- for the power supplies of the batteries and the electric locks: minimum 2.5 mm  

2

2

- for the power supplies of the control unit: section 1.5mm  for maximum length of 19m, section 2.5mm  for lengths up 

to 31m,

2

2

- for the flashing light section 0.75mm  for maximum lengths of 3m, section 1.5mm  for lengths up to 19m.
- for low voltage and current lines, such as photocells, control buttons, electro-mechanical key, sensitive edges and 

2

2

other safety devices: section 0.5mm  for maximum length of 50m, section 0.75mm  for lengths up to 100m,

1 2 3 4 5 6 7 8

9 10 11 12 13 14 15 16 17 18 19 20 21 22

23 24

28 27

34 33

P3

P2

P1

-

+

-

+

-

+

VELOC.

RALL

AMP

ON

1 2

4

3

SW1

ON

1 2

4

3

SW2

25 26

F2

F2

F3

F3

F1

F1

F4

F4

SW3

Summary of Contents for CR/41/24

Page 1: ...hibits the realisation of these types of plants by unqualified staff On realisation of its own products SERAI has respected the following Reference Directives for CE marking machinery 2006 42 EEC low...

Page 2: ...en the lid from the opposite side proceed as follows ATTENTION This operation must be carried out before fixing the container to the wall Insert a flat tip screwdriver into the fixing recess of the hi...

Page 3: ...le to the rest of the system to a minimum The control unit must be fixed via the cable passage holes facing downwards NO NO YES 6 8 mm Recommendations for connections in general rooms 1 Upstream from...

Page 4: ...meter at maximum the amperometric control is excluded RALL POTENTIOMETER speed regulation during the slowing phase with the potentiometer at maximum slowing is excluded VELOC POTENTIOMETER regulation...

Page 5: ...ontrol for electric lock SERAI M 83 1 With SW2dip2 ON control with the gate open indicator light function Input for the connection of the antenna for the built in receiver 33 BRAIDING EARTH 34 ANTENNA...

Page 6: ...ter ATTENTION in this case there may be difficulties on start up if the force is regulated low 1 2 3 ON 4 1 2 3 ON 4 1 2 3 ON 4 1 2 3 ON 4 CLAMPS 11 12 FUNCTIONING MODE Open gate indicator light outpu...

Page 7: ...essary to terminate the wing run with a certain approximation always slowing in the programmed point ATTENTION The lack of power supply to the circuit board network or battery causes the loss of the m...

Page 8: ...key P2 WORK down until M1 starts When Motor M1 should start slowing we recommend at least 50cm before the stop press key P2 WORK The motor M1 slows down ATTENTION skip this point if slowing has been e...

Page 9: ...s is set by regulating the AMP potentiometer The intervention of the amperometric control can be more or less rapid depending on the sensitivity set with the SW3 jumper The gate inverts movement for a...

Page 10: ...2 OG 04 as pedestrian control the others do not have to be memorised OG 02 and OG 04 just set the micro switches in the same sequence as that memorised LEARNING START CODE With the control unit powere...

Page 11: ...ALL AMP ON 1 2 4 3 SW1 ON 1 2 4 3 SW2 25 26 F2 F2 F3 F3 F1 F1 F4 F4 SW3 LED DL6 DL1 PED DL2 START DL3 STOP DL4 FOTO DL5 FOTOAP DL7 COSTA PAUSA LAVORO PROGR BATTERY Power supply transformer 230 20 Vac...

Page 12: ...ntiometer regulates the amperometeric control intervention which intervenes every time that the gate stops moving for a brief period of time due to external factors such as gusts of wind for example T...