PROGRAMMING OPEN GATE PAUSE TIME (AUTOMATIC RE-CLOSURE)

With the control unit powered and gate closed, press key P3 (PROGR.) once. The LD6 LED starts to flash 
indicating that the board has entered the programming phase.

Press key P1 once (PAUSE), the control unit starts the open gate pause count, highlighted with fast 
flashing of the DL6 LED and of the flashing light.

When the desired time has passed, press key P1 (PAUSE) again, the control unit automatically memorises 
the time passed between the two times the key P1 (PAUSE) was pressed and leaves programming, going 
back to normal functioning.
If key P1 (PAUSE) is not pressed a second time, after 120s the control unit escapes from the programming 
memorising the max time of 120s.

ACTIVATE AUTOMATIC RE-CLOSURE (maximum time that can be set 120s)

Press and hold key P1 (PAUSE) until LED DL6 switches off.
The control unit leaves the programming phase and sets itself for normal functioning.
Automatic re-closure is deactivated in this way.

DEACTIVATE AUTOMATIC RE-CLOSURE

With the control unit powered and the gate closes, press key P3 (PROGR.) once to enter programming. 
LED DL6 starts to flash, indicating that the board has entered the programming phase.

BEHAVIOUR WHEN 
STRIKING AN 
OBSTACLE 
FOLLOWING THE 
INTERVENTION OF 
THE AMPEROMETRIC 
CONTROL

during closing at 
normal speed

during opening/closing at 
slowed speed

during opening at 
normal speed

The gate blocks, i.e. the obstacle is interpreted as the 
stop

AMPEROMETRIC SAFETY CONTROL

The control unit has a current absorption control able to intervene in the case of a blow with an obstacle during 
movement at normal speed.

 The current level, above which the amperometric control intervenes, is set by 

regulating the "AMP" potentiometer

. The intervention of the amperometric control can be more or less rapid 

depending on the sensitivity set with the SW3 jumper.

The gate inverts movement for about 5cm. It re-closes 
(part M2 and after the phasing time in closure mode M1 
starts) after the open gate pause time (if automatic re-
closure is activated) or after 30s (if automatic re-closure 
is deactivated).

!

MOTOR SHUTDOWN CONTROL

The control unit has "shutdown motor" control able to intervene with the same consequences as the amperometeric 
control, when the motor remains completely at a standstill for a couple of seconds.
It is a control that cannot be regulated or excluded - it also intervenes with amperometric control excluded - which is 
used to identify the stops during slowing and any gate blocks during the normal run.

ATTENTION: 
- Setting an amperometric level that is too low varies external factors - e.g. gusts of wind, the 

increase of friction between day and night etc.- can be interpreted as a blow with an obstacle 
with intervention of the amperometric control. For this reason it is possible to exclude the 
amperometric control - with "AMP" potentiometer at maximum- even if the motor shutdown 
control remains.

- If the amperometric control is excluded the safety of the blow is less -the gate continues to push 

with maximum force- and therefore it 

is the responsibility of the installer to use all other 

safety systems

 -for example, edges- 

according to that established by the Standards in 

force

.

C

R

/4

1

/2

4

 I

 E

The gate inverts movement for about 5cm and then re-
opens (first M1 and after the phase difference time in 
opening M2 starts) up to the opening stops. It closes 
again after the gate open pause time (if automatic re-
closure is active) or after 30 s (if automatic closure is 
deactivated).

N.B. After 2 consecutive blows in closure, the gate 
blocks and remains in stand-by for a closure 
control

Summary of Contents for CR/41/24

Page 1: ...hibits the realisation of these types of plants by unqualified staff On realisation of its own products SERAI has respected the following Reference Directives for CE marking machinery 2006 42 EEC low...

Page 2: ...en the lid from the opposite side proceed as follows ATTENTION This operation must be carried out before fixing the container to the wall Insert a flat tip screwdriver into the fixing recess of the hi...

Page 3: ...le to the rest of the system to a minimum The control unit must be fixed via the cable passage holes facing downwards NO NO YES 6 8 mm Recommendations for connections in general rooms 1 Upstream from...

Page 4: ...meter at maximum the amperometric control is excluded RALL POTENTIOMETER speed regulation during the slowing phase with the potentiometer at maximum slowing is excluded VELOC POTENTIOMETER regulation...

Page 5: ...ontrol for electric lock SERAI M 83 1 With SW2dip2 ON control with the gate open indicator light function Input for the connection of the antenna for the built in receiver 33 BRAIDING EARTH 34 ANTENNA...

Page 6: ...ter ATTENTION in this case there may be difficulties on start up if the force is regulated low 1 2 3 ON 4 1 2 3 ON 4 1 2 3 ON 4 1 2 3 ON 4 CLAMPS 11 12 FUNCTIONING MODE Open gate indicator light outpu...

Page 7: ...essary to terminate the wing run with a certain approximation always slowing in the programmed point ATTENTION The lack of power supply to the circuit board network or battery causes the loss of the m...

Page 8: ...key P2 WORK down until M1 starts When Motor M1 should start slowing we recommend at least 50cm before the stop press key P2 WORK The motor M1 slows down ATTENTION skip this point if slowing has been e...

Page 9: ...s is set by regulating the AMP potentiometer The intervention of the amperometric control can be more or less rapid depending on the sensitivity set with the SW3 jumper The gate inverts movement for a...

Page 10: ...2 OG 04 as pedestrian control the others do not have to be memorised OG 02 and OG 04 just set the micro switches in the same sequence as that memorised LEARNING START CODE With the control unit powere...

Page 11: ...ALL AMP ON 1 2 4 3 SW1 ON 1 2 4 3 SW2 25 26 F2 F2 F3 F3 F1 F1 F4 F4 SW3 LED DL6 DL1 PED DL2 START DL3 STOP DL4 FOTO DL5 FOTOAP DL7 COSTA PAUSA LAVORO PROGR BATTERY Power supply transformer 230 20 Vac...

Page 12: ...ntiometer regulates the amperometeric control intervention which intervenes every time that the gate stops moving for a brief period of time due to external factors such as gusts of wind for example T...