36
0040-01
Winching out
Oil in at
V2
.
The shuttle valve
C
opens and permits
oil flow to measuring point
E
and to the
brake
F
which releases when the
pressure exceeds 30 bar.
The pilot line
K
leads oil to the Over
Centre Valve
L
. This valve opens at
approximately 70 bar so that oil from
the motor can return to the tank.
The oil flows to all motors
M1-3
and
passes through Over Centre Valve
L
and out through
V1
.
(Red lines in the circuit diagrams = oil flow. Green lines = only pressure).