SAFETY AND PRECAUTIONS

Read all the information, the datasheet, mounting and operating instructions and 
study the wiring and connection diagram before working with the product. For 
personal and equipment safety, and for optimum product performance, make sure you 
entirely understand the contents before installing, using, or maintaining this product.

For safety and licensing (CE) reasons, unauthorised conversion and / or modifications 
of the product are inadmissible.

The product should not be exposed to abnormal conditions, such as: extreme 
temperatures, direct sunlight or vibrations. Long-term exposure to chemical 
vapours in high concentration can affect the product performance. Make sure the 
work environment is as dry as possible; avoid condensation.

All installations shall comply with local health and safety regulations and local 
electrical standards and approved codes. This product can only be installed by an 
engineer or a technician who has expert knowledge of the product and safety 
precautions.

Avoid contacts with energised electrical parts. Always disconnect the power 
supply before connecting, servicing or repairing the product.

Always verify that you apply appropriate power supply to the product and use 
appropriate wire size and characteristics. Make sure that all the screws and nuts 
are well tightened and fuses (if any) are fitted well.

Recycling of equipment and packaging should be taken into consideration and these 
should be disposed of in accordance with local and national legislation / regulations.

In case there are any questions that are not answered, please contact your 
technical support or consult a professional.

 

 

MTP-G010-AT

ACTIVE 
POTENTIOMETER

Summary of Contents for MTP-G010-AT

Page 1: ...Mounting and operating instructions MTP G010 AT ACTIVE POTENTIOMETER ...

Page 2: ... PRODUCT DESCRIPTION 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND CONNECTIONS 5 MOUNTING INSTRUCTIONS IN STEPS 5 VERIFICATION OF INSTALLATION INSTRUCTIONS 7 TRANSPORT AND STORAGE 7 WARRANTY AND RESTRICTIONS 7 MAINTENANCE 7 MTP G010 AT ACTIVE POTENTIOMETER ...

Page 3: ...environment is as dry as possible avoid condensation All installations shall comply with local health and safety regulations and local electrical standards and approved codes This product can only be installed by an engineer or a technician who has expert knowledge of the product and safety precautions Avoid contacts with energised electrical parts Always disconnect the power supply before connect...

Page 4: ...ounting ARTICLE CODES Article code Power supply Output MTP G010 AT 24 VAC or 24 VDC 0 10 VDC INTENDED AREA OF USE Applications where a 0 10 VDC control signal is required For indoor use only TECHNICAL DATA Power supply 24 VAC or 24 VDC Output Vmin Vmax Load RL 2 kΩ Vmin 0 7 VDC Vmax 3 10 VDC Enclosure External ASA white ivory RAL 9010 IP54 according to EN 60529 Internal polyamide white ivory RAL 9...

Page 5: ...ns Cable cross section max 2 5 mm MOUNTING INSTRUCTIONS IN STEPS Before you start mounting your potentiometer read carefully Safety and Precautions and follow the steps For inset mounting 1 Remove the knob by turning it to the right until it pops out 2 Unscrew the nut to remove the cover of the external enclosure 3 Do the wiring according to the wiring diagram see Fig 1 Wiring and connections Fig ...

Page 6: ...ce mounting 1 Remove the knob by turning it to the right until it pops out 2 Unscrew the nut to remove the cover of the external enclosure 3 Mount the external enclosure onto the surface by means of screws and dowels not included adhering to the mounting dimensions shown in Fig 3 Mounting dimensions surface mounting Fig 3 Mounting dimensions surface mounting 82 89 69 82 62 62 4 Insert the cables t...

Page 7: ...onditions stock in original packing WARRANTY AND RESTRICTIONS Two years from the delivery date against defects in manufacturing Any modifications or alterations to the product after the date of publication relieve the manufacturer of any responsibilities The manufacturer bears no responsibility for any misprints or mistakes in this data MAINTENANCE In normal conditions this product is maintenance ...