Operating manual Fx9x
.
FACTORY PRESET
All settings are reset to delivery status.
PASSWORD
(OFF)
Activate or deactivate password entry. Delivery status = inactive (OFF).
The password is permanently “
1234
“ and cannot be changed.
When the device is set to “Password ON“ , it is only possible to quit operating mode when 1234 has been
entered as password.
Measuring mode continues in the background whilst the password is being entered. Should no entry be made in
the password input menu over a period of approx. 10 seconds, operating mode reappears on the display.
Operating example for menu: QuickSet
Menu level 1
Operation 1.0
Display:
1st line: Text “DIST mm“
2nd line: current measured value
Password input
Menu level 1
PASSWORD1.1
(Only when “PASSWORD“ active, delivery status = inactive)
Increases current digit by 1
Reduces current digit by 1
Jumps one digit further or “confirms input” when the far left digit has been reached and
is pressed.
Menu level 2:
if input is correct and completed with
Operating mode:
if input is wrong or with timeout after approx. 10 sec.
Menu level 2
QuickSet 2.1
UNIT 2.2
SERIAL 2.3
RS422/SSI 2.4
OFFSET 2.5
......... 2.x
Password 2.8
ESC
DIST mm
123456
ESC
PASSWORD
____
Level 3
Menu level 3
QuickSet 2.1.1
ESC
QuickSet
<SETUP>
ESC
UNIT
<act. unit>
ESC
SERIAL
<act. value>
ESC
RS422 or SSI
or BUS
ESC
OFFSET
<act. value>
ESC
.......
<......>
ESC
PASSWORD
<ON>/<OFF>
Teach-in Q1 or Q2
Confirm input and switch one menu level up
ESC
Switch one menu level up
EE
Energy value for alignment
ESC
4564mm
Q1 ||||||| q2
SensoPart Industriesensorik GmbH, D-79695 Wieden, Tel. +49 (0)7673 821-0 Fax +49 (0)7673 821-30 www.sensopart.de
Page 9
Status 21.10.2004 Software 1.51 and higher 068-13621