![Sensopart SmartRange FR 90 ILA Operating Manual Download Page 11](http://html1.mh-extra.com/html/sensopart/smartrange-fr-90-ila/smartrange-fr-90-ila_operating-manual_1243961011.webp)
Operating manual Fx9x
.
„GDB“
get energy
-
Energy value –0 to -120dB
indicates the amount of receiving
energy
„GNR“
get serial number
-
„xxxxxxxxxx“
Serial no. is emitted as ASCII test
(max. 24 characters).
„GSI“
get error status
-
„DDDDDDD“
76543210
Output of error status, with D=“0“:
no error D=“1“:error:
D7: Transmitter faulty
D6: Receiver blinded or faulty
D5: Temperature warning:
T < -10
°
C or T > +70
°
C
D4: Target out of range or
transmitter faulty
D3: Temperature error: T > +85
°
C
D2: Supply voltage too low
D1: PLL unlocked
D0: always “0“
„GTE“ get
temperature
-
„
±
DDD“
DDD = internal temperature in
°
C
„GVE“
get version
„Fx9x $Revision X.XX$“
Software version is sent
„GCM“
help command
/
get commands
-
All available commands
All available commands are sent in
text format
„ICM“ input
continuous
mode
„0“ , „1“
ACK
Measurement mode setting:
“0“ = continuous measurement
output, “1“ = output of single
measurement values
„IDO“
input offset
-12000..+12000 or
-48000..+48000
ACK
Setting offset in [mm] or
[INCH * 100]
„IH1“
input hysteresis Q1
„000“.. „254“
or
„000“..“999“ (INCH)
ACK
Setting hysteresis around
switching points of Q1 in [mm] or
[INCH * 100]
„IH2“
input hysteresis
„000“.. „254“
or
„000“..“999“ (INCH)
ACK
Setting hysteresis around switching
points of Q2 in [mm] or [INCH *
100]
„IL1“
input limit
Q1 – 1
Offset ...
+12000+Offset or
Offset ..
48000+Offset
ACK
Setting the first switching point of
Q1 in [mm]
or [INCH*100]
„IL2“
input limit
Q2 – 1
Offset ...
+12000+Offset or
Offset ..
48000+Offset
ACK
Setting the first switching point of
Q2 in [mm]
or [INCH*100]
„IL3“
input limit
Q analog 1
Offset ...
+12000+Offset
ACK
Proximity switch only:
Setting 0% point of characteristic
analog curve
„IL4“
input limit
Q1 – 2
Offset ...
+12000+Offset or
Offset ..
48000+Offset
ACK
Setting second switching point of
Q1 in [mm]
or [INCH*100]
„IL5“
input limit
Q2 – 2
Offset ...
+12000+Offset or
Offset ..
48000+Offset
ACK
Setting second switching point of
Q2 in [mm]
or [INCH*100]
„IL6“
input limit
Q analog 2
Offset ...
+12000+Offset
ACK
Proximity switch only
Setting 100% point of characteristic
analog curve
„IM1“
input mode Q1
“0“, “1“, “2“
ACK
“0“ = inactive, “1“= 1 switching
point,
“2“ = 2 switching points
„IM2“
input mode Q2
“0“, “1“, “2“
ACK
“0“ = inactive, “1“= 1 switching
point,
“2“ = 2 switching points
„INA“
input norm
Q analog
“0“, “1“,
ACK
Proximity switch only
“0“= Q, “1“=Q inverted
„IN1“
input norm Q1
“0“, “1“,
ACK
“0“= Q, „1“=Q inverted
„IN2“
input norm Q2
“0“, “1“,
ACK
“0“= Q, „1“=Q inverted
„IVL“
Input visible laser
„0“ , „1“
ACK
„0“=Pilotlaser off, „1“=Pilotlaser on
SensoPart Industriesensorik GmbH, D-79695 Wieden, Tel. +49 (0)7673 821-0 Fax +49 (0)7673 821-30 www.sensopart.de
Page 11
Status 21.10.2004 Software 1.51 and higher 068-13621