Sensopart SmartRange FR 90 ILA Operating Manual Download Page 11

Operating manual Fx9x 

 

.   

 

„GDB“ 

get energy 

Energy value –0 to -120dB 

indicates the amount of receiving 

energy   

„GNR“ 

get serial number 

„xxxxxxxxxx“ 

Serial no. is emitted as ASCII test 

(max. 24 characters).  

„GSI“ 

get error status 

„DDDDDDD“ 

76543210 

Output of error status, with D=“0“: 

no error D=“1“:error: 

D7: Transmitter faulty 
D6: Receiver blinded or faulty     
D5: Temperature warning:  
        T < -10

°

C or T > +70

°

D4: Target out of range or 

transmitter faulty  

D3: Temperature error: T > +85

°

D2: Supply voltage too low 
D1: PLL unlocked 
D0: always “0“ 

„GTE“ get 

temperature 

±

DDD“ 

DDD = internal temperature in 

°

„GVE“ 

get version 

 

„Fx9x $Revision X.XX$“ 

Software version is sent 

 „GCM“ 

help command 

get commands 

All available commands 

All available commands are sent in 

text format  

„ICM“ input 

continuous 

mode 

„0“  ,  „1“ 

ACK 

Measurement mode setting: 

“0“ = continuous measurement 

output, “1“ = output of single 

measurement values 

„IDO“ 

input offset 

-12000..+12000 or 

-48000..+48000 

ACK 

Setting offset in [mm] or 

 [INCH * 100] 

„IH1“ 

input hysteresis Q1 

„000“.. „254“  

or 

„000“..“999“ (INCH) 

ACK 

 Setting hysteresis around 

switching points of Q1 in [mm] or 

[INCH * 100] 

„IH2“ 

input hysteresis 

„000“.. „254“  

or 

„000“..“999“ (INCH) 

ACK 

Setting hysteresis around switching 

points of Q2 in [mm] or [INCH * 

100] 

„IL1“ 

input limit  

Q1 – 1 

Offset ... 

+12000+Offset or 

Offset .. 

48000+Offset 

ACK 

Setting the first switching point of 

Q1 in [mm] 

or [INCH*100] 

„IL2“ 

input limit  

Q2 – 1 

Offset ... 

+12000+Offset or 

Offset .. 

48000+Offset 

ACK 

Setting the first switching point of 

Q2 in [mm] 

or [INCH*100] 

„IL3“ 

input limit  

Q analog 1 

Offset ... 

+12000+Offset 

 
 

ACK 

Proximity switch only: 

Setting 0% point of characteristic 

analog curve 

„IL4“ 

input limit  

Q1 – 2 

Offset ... 

+12000+Offset or 

Offset .. 

48000+Offset 

ACK 

Setting second switching point of  

Q1 in [mm] 

or [INCH*100] 

„IL5“ 

input limit  

Q2 – 2 

Offset ... 

+12000+Offset or 

Offset .. 

48000+Offset 

ACK 

Setting second switching point of  

Q2 in [mm] 

or [INCH*100] 

„IL6“ 

input limit  

Q analog 2 

Offset ... 

+12000+Offset 

ACK 

Proximity switch only 

Setting 100% point of characteristic 

analog curve 

„IM1“ 

input mode Q1 

 “0“,  “1“,  “2“  

ACK 

“0“ = inactive,  “1“= 1 switching 

point, 

“2“ = 2 switching points 

„IM2“ 

input mode Q2 

 “0“,  “1“,  “2“ 

ACK 

“0“ = inactive,  “1“= 1 switching 

point, 

“2“ = 2 switching points 

„INA“ 

input norm  

Q analog 

 “0“,  “1“,   

ACK 

Proximity switch only 

“0“= Q,  “1“=Q inverted 

„IN1“ 

input norm Q1 

 “0“,  “1“,   

ACK 

“0“= Q,  „1“=Q inverted 

„IN2“ 

input norm Q2 

 “0“,  “1“,   

ACK 

“0“= Q,  „1“=Q inverted 

„IVL“ 

Input visible laser 

„0“ , „1“ 

ACK 

„0“=Pilotlaser off, „1“=Pilotlaser on 

 

 

 

 

 

SensoPart Industriesensorik GmbH, D-79695 Wieden, Tel. +49 (0)7673 821-0 Fax +49 (0)7673 821-30   www.sensopart.de 

Page 11 

Status 21.10.2004    Software 1.51 and higher                068-13621 

 

Summary of Contents for SmartRange FR 90 ILA

Page 1: ...easuring device FR 91 ILA Reflector distance sensor FT 90 ILA Distance measuring device FT 91 ILA Distance sensor SensoPart Industriesensorik GmbH D 79695 Wieden Tel 49 0 7673 821 0 Fax 49 0 7673 821...

Page 2: ...be detected or measured over long distances The FT90ILA and FT91ILA devices differ in performance data see the chapter on technical data SmartRange sensors are equipped with the following LCD display...

Page 3: ...ight spot is in the centre of the reflector at a very short distance e g 1 m The reflector is then moved to its final position with the longest range and the position of the light spot is checked agai...

Page 4: ...the information pictured below when aligning the devices Aussparung Farbwechsel Erh hung Ok Ok Drehende Welle Rotating shaft Dimensions of light spot Fx9xILA 27 5mm 4m 6m 10m 3mm x 10mm 4mm x 12mm 10...

Page 5: ...tion right or increases current digit by 1 when editing In QuickSet menu it enables the teach in of Q2 In measuring mode press this button to make the display light up Left arrow button General scroll...

Page 6: ...1 Teach1 2 HYST 1 4564mm Q1 q2 Offset 0 OFFSET nnnn OFFSET CLEAR UNIT MM UNIT MM UNIT INCH SERIAL SSI SERIAL EXT BUS SERIAL RS422 SERIAL RS422 SSI Gray25 Ext Bus Search Parameter Setup Factory OK Pass...

Page 7: ...I EXT_BUS With Serial Select it is possible to select the interface from RS422 SSI1 10 SSI1 8 compatible or EXTernal BUSadapter When EXT BUS is selected SEARCH BUS appears in the display until the con...

Page 8: ...nt range is valid as upper limit Analog output 0 to 20 mA only FT9x detector Mode 1 rising characteristic curve Mode 2 falling characteristic curve COPY Q A Q1 Q2 Switching point Q1 1 becomes 0 point...

Page 9: ...hen PASSWORD active delivery status inactive Increases current digit by 1 Reduces current digit by 1 Jumps one digit further or confirms input when the far left digit has been reached and is pressed M...

Page 10: ...EE INV ON OFF Q2 AA MODE BB LIMIT1 CC LIMIT2 DD HYST EE INV ON OFF proximity switch only Qana VALUE FF LIMIT1 CC LIMIT2 DD INV ON OFF output GG offset YYYY password dis enabled Error Status DDDDDDDD a...

Page 11: ...g points of Q2 in mm or INCH 100 IL1 input limit Q1 1 Offset 12000 Offset or Offset 48000 Offset ACK Setting the first switching point of Q1 in mm or INCH 100 IL2 input limit Q2 1 Offset 12000 Offset...

Page 12: ...error status can be questioned via the GSI command In principle a combination of several errors can exist e g too low a supply voltage can cause a counter error In this case the GSI command would repo...

Page 13: ...5mm 0 1mm or 0 125mm Repeatability 2 mm 4 mm 5 mm 5 mm Linearity 10 mm 10 mm 15 mm 15 mm Response time 12 ms 12 ms 12 ms 12 ms Temperature drift 0 5 mm K 0 5 mm K Thermal response 5mm absolute 5mm abs...

Page 14: ...ue White Signal output Q2 M GND Blue Blue 0 V GND Cable lengths shield Cable length RS422 The RS422 interface is defined as a reliable serial interface in full duplex mode with transfer rates up to 10...

Page 15: ...12 wires 20m 12 pin connector M16 90 angle 902 51665 Connection cable 12 wires 30m 12 pin connector M16 90 angle 902 51666 Cables 12 wires Connection cable 5 wires 3m 12 pin connector M16 straight 90...

Page 16: ...aid The aligning aid allows to see the spot of the pilot laser at large distances Using the aligning aid Mount the aligning aid on Fx9x front side Activate any menu item Pilotlaser on Look into the s...

Page 17: ...248 218 218 6 5 4 5 RL 460 460 460 430 430 6 5 4 5 RL 660 660 660 630 630 6 5 4 5 RL 540 540 540 510 510 6 5 6 8 RL 700 700 700 670 670 6 5 6 8 SensoPart Industriesensorik GmbH D 79695 Wieden Tel 49 0...

Page 18: ...Bit 6 Receiver blinded or faulty Bit 5 Temperature warning T 10 C or T 70 C Bit 4 No stop signal target out of range or receiver faulty Bit 3 Temperature error T 85 C Bit 2 Supply voltage too low Bit...

Reviews: