Sensopart SmartRange FR 90 ILA Operating Manual Download Page 15

Operating manual Fx9x 

 

.   

VII. Order data / Devices and accessories 

 

Sensors Order 

no. 

FT90 ILA-S2-Q12 (Distance measuring device) 

591-91000 

FR90 ILA-S2-Q12 (Reflector distance measuring device) 

591-91001 

FT91 ILA-S2-Q12 (Distance sensor) 

591-91003 

FR91 ILA-S2-Q12 (Reflector distance sensor ) 

591-91002 

 

 

Cables 12 wires 

 

Connection cable 12 wires, 10m, 12 pin connector, M16, straight 

902-51658 

Connection cable 12 wires, 20m, 12 pin connector, M16, straight 

902-51663 

Connection cable 12 wires, 30m, 12 pin connector, M16, straight 

902-51664 

Connection cable 12 wires, 3m, 12 pin connector, M16, 90° angle 

902-51659 

Connection cable 12 wires, 5m, 12 pin connector, M16, 90° angle 

902-51660 

Connection cable 12 wires, 10m, 12 pin connector, M16, 90° angle 

902-51661 

Connection cable 12 wires, 20m, 12 pin connector, M16, 90° angle 

902-51665 

Connection cable 12 wires, 30m, 12 pin connector, M16, 90° angle 

902-51666 

 

 

 

 

Cables 12 wires 

 

Connection cable 5 wires, 3m, 12 pin connector, M16, straight 

902-51682 

Connection cable 5 wires, 3m, 12 pin connector, M16, 90° angle 

902-51681 

 

 

Connectors  

Connector plug straight, 12 pin, M16 

022-50832 

Connector plug 90° angle, 12 pin, M16 

022-50831 

 

 

Various  

Mounting bracket Fx91 

599-91002 

Fine adjustment for mounting bracket Fx91(set of 2 pcs.) 

599-91003 

Aligning aid 

599-91004

 

Plug adapter ProfiBus 

599-91005 

Plug adapter DeviceNet 

599-91008 

PC software 

599-91000 

 

 

Reflectors 

 

Reflector foil RF250 

599-91009 

Reflector RL 250  

904-51562 

Reflector RL 460 

904-51565 

Reflector RL 660 

904-51564 

Reflector RL 540 

904-51571 

Reflector RL 700 

904-51570 

 

 

 

SensoPart Industriesensorik GmbH, D-79695 Wieden, Tel. +49 (0)7673 821-0 Fax +49 (0)7673 821-30   www.sensopart.de 

Page 15 

Status 21.10.2004    Software 1.51 and higher                068-13621 

 

Summary of Contents for SmartRange FR 90 ILA

Page 1: ...easuring device FR 91 ILA Reflector distance sensor FT 90 ILA Distance measuring device FT 91 ILA Distance sensor SensoPart Industriesensorik GmbH D 79695 Wieden Tel 49 0 7673 821 0 Fax 49 0 7673 821...

Page 2: ...be detected or measured over long distances The FT90ILA and FT91ILA devices differ in performance data see the chapter on technical data SmartRange sensors are equipped with the following LCD display...

Page 3: ...ight spot is in the centre of the reflector at a very short distance e g 1 m The reflector is then moved to its final position with the longest range and the position of the light spot is checked agai...

Page 4: ...the information pictured below when aligning the devices Aussparung Farbwechsel Erh hung Ok Ok Drehende Welle Rotating shaft Dimensions of light spot Fx9xILA 27 5mm 4m 6m 10m 3mm x 10mm 4mm x 12mm 10...

Page 5: ...tion right or increases current digit by 1 when editing In QuickSet menu it enables the teach in of Q2 In measuring mode press this button to make the display light up Left arrow button General scroll...

Page 6: ...1 Teach1 2 HYST 1 4564mm Q1 q2 Offset 0 OFFSET nnnn OFFSET CLEAR UNIT MM UNIT MM UNIT INCH SERIAL SSI SERIAL EXT BUS SERIAL RS422 SERIAL RS422 SSI Gray25 Ext Bus Search Parameter Setup Factory OK Pass...

Page 7: ...I EXT_BUS With Serial Select it is possible to select the interface from RS422 SSI1 10 SSI1 8 compatible or EXTernal BUSadapter When EXT BUS is selected SEARCH BUS appears in the display until the con...

Page 8: ...nt range is valid as upper limit Analog output 0 to 20 mA only FT9x detector Mode 1 rising characteristic curve Mode 2 falling characteristic curve COPY Q A Q1 Q2 Switching point Q1 1 becomes 0 point...

Page 9: ...hen PASSWORD active delivery status inactive Increases current digit by 1 Reduces current digit by 1 Jumps one digit further or confirms input when the far left digit has been reached and is pressed M...

Page 10: ...EE INV ON OFF Q2 AA MODE BB LIMIT1 CC LIMIT2 DD HYST EE INV ON OFF proximity switch only Qana VALUE FF LIMIT1 CC LIMIT2 DD INV ON OFF output GG offset YYYY password dis enabled Error Status DDDDDDDD a...

Page 11: ...g points of Q2 in mm or INCH 100 IL1 input limit Q1 1 Offset 12000 Offset or Offset 48000 Offset ACK Setting the first switching point of Q1 in mm or INCH 100 IL2 input limit Q2 1 Offset 12000 Offset...

Page 12: ...error status can be questioned via the GSI command In principle a combination of several errors can exist e g too low a supply voltage can cause a counter error In this case the GSI command would repo...

Page 13: ...5mm 0 1mm or 0 125mm Repeatability 2 mm 4 mm 5 mm 5 mm Linearity 10 mm 10 mm 15 mm 15 mm Response time 12 ms 12 ms 12 ms 12 ms Temperature drift 0 5 mm K 0 5 mm K Thermal response 5mm absolute 5mm abs...

Page 14: ...ue White Signal output Q2 M GND Blue Blue 0 V GND Cable lengths shield Cable length RS422 The RS422 interface is defined as a reliable serial interface in full duplex mode with transfer rates up to 10...

Page 15: ...12 wires 20m 12 pin connector M16 90 angle 902 51665 Connection cable 12 wires 30m 12 pin connector M16 90 angle 902 51666 Cables 12 wires Connection cable 5 wires 3m 12 pin connector M16 straight 90...

Page 16: ...aid The aligning aid allows to see the spot of the pilot laser at large distances Using the aligning aid Mount the aligning aid on Fx9x front side Activate any menu item Pilotlaser on Look into the s...

Page 17: ...248 218 218 6 5 4 5 RL 460 460 460 430 430 6 5 4 5 RL 660 660 660 630 630 6 5 4 5 RL 540 540 540 510 510 6 5 6 8 RL 700 700 700 670 670 6 5 6 8 SensoPart Industriesensorik GmbH D 79695 Wieden Tel 49 0...

Page 18: ...Bit 6 Receiver blinded or faulty Bit 5 Temperature warning T 10 C or T 70 C Bit 4 No stop signal target out of range or receiver faulty Bit 3 Temperature error T 85 C Bit 2 Supply voltage too low Bit...

Reviews: