Operating manual Fx9x
.
IV. Commands via the serial interface (RS422 protocol)
All commands have the following structure:
<STX><Command><[Data]><EOT>
All commands are answered by Fx9xILA as follows:
<NAK>
= the command was not recognised or the data is outside the limit values.
or
<ACK>
=
the command was recognised and executed, the command requires no return data.
or
<Data> =
the command was recognised and the requested data has been sent.
Definitions:
STX
= start transmission = 02h = CTRL B
EOT
= end of text = 04h = CTRL D
NAK
= no acknowledge = 15h = CTRL U
ACK
= acknowledge = 06h = CTRL F
Command
= 3 digit command (ASCII text)
[Data] = whole numbers (ASCII text)
In ASCII text (data) spaces and capitals/small letters are ignored.
User commands and their meaning
Comm
and
Name
Data to Fx9x
Data from Fx9x
Meaning
„GAP“ get all parameters
-
all parameters in text format:
„Fx9xILA $Revision
X.XX
$“
„pilot is on/off/xx seconds on“
Uart mode
„Q1:
AA
MODE=
BB
LIMIT1=
CC
LIMIT2=
DD
HYST=
EE
INV=ON/OFF“
„Q2:
AA
MODE=
BB
LIMIT1=
CC
LIMIT2=
DD
HYST=
EE
INV=ON/OFF“
(proximity switch only : „Qana:
VALUE=
FF
LIMIT1=
CC
LIMIT2=
DD
INV=ON/OFF )
„output =
GG
“
„offset =
YYYY
“
„password dis/enabled“
„Error-Status =
DDDDDDDD
all parameters of Fx9x are read:
X.XX
: Revision
no.
YYYY
: User offset
[mm] or [10 MIL]
AA
: „ON“=HIGH
output,
„OFF“=LOW
output
BB
:
Mode:
„0“ = Output off,
„1“ = 1 Switching point
„2“ = 2 Switching points
CC
:
Switching point 1,
Offset..12000+Offset
DD
:
Switching point 2,
Offset..12000+Offset
EE
:
Hysteresis, 0 to 254 [mm]
GG:
Unit of meas., „10 MIL“
or
„MM“
DDD
: Error status:
FF:
Analog value, 0 to 4095
Output of error status, with D=“0“:
no error D=“1“:error:
D7: Transmitter faulty
D6: Receiver blinded or faulty
D5: Temperature warning:
T < -10
°
C or T > +70
°
C
D4: Target out of range or
transmitter faulty
D3: Temperature error: T > +80
°
C
D2: Supply voltage too low
D1: PLL unlocked
D0: always “0“
„ECM“ execute
continuous
measurement
-
ACK
continuous measurement output is
set and triggered by the next
request for measured values
SensoPart Industriesensorik GmbH, D-79695 Wieden, Tel. +49 (0)7673 821-0 Fax +49 (0)7673 821-30 www.sensopart.de