![Sensia QRATE Scanner 3300 Installation, Operation & Maintenance Manual Download Page 20](http://html1.mh-extra.com/html/sensia/qrate-scanner-3300/qrate-scanner-3300_installation-operation-and-maintenance-manual_1243467020.webp)
Table 1.3—Scanner Companion Software
Important To download software or software user manuals, visit the Sensia website at
https://www.sensiaglobal.com/Measurement/Types/Flow-Computing-and-Automation
QRATE
Scanner 3000 series integrated control flow computers
, and click on the link for the desired
software install/manual.
Scanner Logic
IDE
Creates Scanner Logic scripts (SLOGIC) and compiles them into a logic-controller program file
(SLBIN).
Performs live debugging on scripts, showing immediate and upcoming script sections to be
debugged.
Uses a high-level procedural programming language designed to build logic controllers. In this way,
the program resembles a state machine.
Scanner Data
Manager
Opens proprietary data files (.sdf) downloaded from the QRATE Scanner 3300 and provides tools for
data analysis, reporting, export and conversion
Presents data in tabular and trend views
Includes tools for customizing reports
ScanMap
Creates custom QRATE Scanner 3300 Modbus register maps, including user-specified units, rates,
and register names for SCADA integration
Firmware-specific templates
Auto-generates protocol manual for printing or uploading to the web interface
ScanFlash
Uploads firmware (BIN), configuration (SRF), Scanner Logic IDE file (SLBIN), and custom Modbus
register map (PMAP) files to the QRATE Scanner 3300
PC Requirements
Windows 7 or later operating system
1 GHz or faster 32-bit (x86) or 64-bit (x64) processor
1 GB RAM (32-bit) or 2 GB RAM (64-bit) available hard disk space (360 MB for companion software installation, 30
MB for software for PDF reading, adequate space for data files)
DirectX 9 graphics device with WDDM 1.0 or later driver
Flow Rate and Fluid Property Calculations
The QRATE Scanner 3300 calculates flow rates and fluid properties for natural gas and liquid flow in accordance with
the following industry standards. The calculations compensate for the effects of pressure, temperature, and fluid compo-
sition to determine mass and volume at specified base conditions. The fluid corrections typically require configuration of
inputs including static pressure and temperature. The flow calculation requires configuration of differential pressure or
pulse (frequency) inputs.
14
Section 1