The Menu
27
Here you can select the activation of extra functions.
1.
Dynamic|Mode:
The Dynamic|Mode is a special algorithm which leads to a more stable clogging-induced
control of the backwashing. With this mode, the backwash water level is continuously
corrected for changes in the water level. Please note, that the backwashing is then not at
exactly the specified backwash water level. Instead it starts when the “corrected”
backwash level is reached.
2.
Eco|Mode
With the Eco-Mode you can decrease the water consumption of your filter. When the water
level sensor initiates the cleaning, only the filter motor is activated for a short time to bring
the until then unused filter mesh into the water. By monitoring the water level, the
AQUACULTURE|CONTROL will decide when the next full cleaning is necessary.
3.
Cover Sw. DF
If the cover switch is defined as “Cover Sw. DF” where DF stands for drum filter, the
backwashing will be stopped, if the cover is opened. Additionally, when the 230 V plug 2 is
defined as “UVC lamp”, it will be also switched off immediately.
4.
Cover Sw. EBF
In case the cover switch is set to EBF, which means “Endlosbandfilter” or continuous belt
filter, a backwashing will not be interrupted when the cover is opened. The UVC on 230 V
plug 2 however will be switched off.
Water level
All water level related parameters are system-specific. In this menu item, you can configure
the cleaning-related water level settings.
Flush Level
The flush level is the water level threshold, under (gravity system) or over (pumped system)
which the cleaning is initiated. It is always displayed positive as a difference.
Dry run Protection
The Dry run Protection level is the water level at which the circulation pump is deactivated
and the system stopped. If the water level is below this level, the AQUACULTURE|CONTROL
tries several times to reactivate the filter. Only if the operation can be safely continued, the
AQUACULTURE|CONTROL goes back into the normal operation mode.
You will see this as a message in the display. The symbol “Pause” will also appear. To restart
the operation manually, press “STOP”.