background image

ENGLISH 8/8

MI004301-E

SETTINGS THROUGH

INTERNAL JUMPERS

ACTIVE / PASSIVE OUTPUT

Active Output Passive Output

J9

SW1

SW2

SW3

FRONTAL PANEL

MODULE DIMENSIONS

Disposal of Electrical & Electronic Equipment (Applicable throughout the European Union and
other  European  countries  with  separate  collections  programs).  This  symbol,  found  on  your
product or on its packaging, indicates that this product should not be treated as household waste
when you wish to dispose of it. Instead, it should be handed over to an applicable collection point
for  the  recycling  of  electrical  &  electronic  equipment.  By  ensuring  this  product  is  disposed  of
correctly, you will help prevent potential negative consequences to the environment and human
health, which could otherwise be caused by inappropriate disposal of this product. The recycling of
materials  will  help  to  conserve  natural  resources.  For  more  detailed  information  about  the
recycling of the product, please contact your local city office, waste disposal service of the retail
store where you purchased this product. 

9. DECOMMISSIONING AND DISPOSAL

8. MODULE LAYOUT

ORDER CODE

SPECIFICATIONS

CU-A-MICROB

USB-microUSB 1 mt communication cable.

CU-A-MICRO-OTG

Adapter cable for smartphone.

7. PURCHASE ORDER CODE

LED

LED STATE

LED MEANING

PWR

Green

ON

Power supply presence

Blinking (freq: 1 flash./sec)

Out of Scale, Burn Out or Internal failure

Blinking (freq 

 2 flash./sec)

DIP-switches setting error

6.6 LED INDICATIONS ON THE FRONTAL PANEL

6.5 

JUMPERS POSITION

J9

J9

Z109UI2-1

USB

PWR/
FAIL

1112

10

1

1

1.0 mm

17.5 mm

100 mm

MADE IN IT

AL

Y

USB

Z109TC2-1

PWR/
FAIL

8 9

7

1

6

V Output*

V

+

2

3

19-28 V      50-60 Hz

10-40 V

2,5 W Max

Class 2

Power Supply

*Please see manual about 

Active / Passive setting

OUTPUT

1

6

mA

 Output*

A

+

1

6

mA

 Output*

A

+

+

ET004362B

Z109UI2-1

V - mA

 T

ransmitter

with galvanic insulation

V - mV input

INPUT

mA

 input (2 Wire)

mA

 input

10

1

1

+

1

1

7

+

10

9

+

Electrical ratings for UL

 standards:

OUTPUT

: 10 V      , 20 mA

INPUT

: 20 V      , 20 mA

OPERA

TING 

TEMP

.: -20 - +60 °C

Summary of Contents for Z109UI2

Page 1: ...9 8706287 Internet site Technical assistance www seneca it support seneca it Commercial reference sales seneca it Chapter index Page 1 Preliminary warnings 2 2 Description and characteristics 2 1 Modu...

Page 2: ...d Measurement and re transmission on isolated analog output with voltage and current output DIP switch for selecting type of input START END output mode zero elevation scale inversion output type mA o...

Page 3: ...ards EN61000 6 4 electromagnetic emission in industrial environment EN61000 6 2 electromagnetic immunity in industrial environment EN61010 1 safety Notes Use with copper conductor Use in Pollution Deg...

Page 4: ...y at least 5 mm in the following cases If the panel operating temperature exceeds 45 C and at least one of the severe operating conditions exists If the panel operating temperature exceeds 35 C and at...

Page 5: ...tput 1 6 V Voltage mA output 1 6 A Generated current 3 mA output External power Supply current 4 1 6 A 5 6 ANALOG OUTPUT Electrical ratings for UL Output 10 V 20 mA Input 20 V 20 mA Operating Temp 20...

Page 6: ...e START and END scale desired SW1 INPUT SELECTION POSITIO N INPUT POSITION INPUT 1 2 3 4 TYPE 1 2 3 4 TYPE V mA SW2 START and END POSITIO N START POSITIO N END 1 2 3 SCALE n 4 5 6 SCALE n 1 1 2 2 3 3...

Page 7: ...the type of input START and END measurement which include the required beginning and end values 2 Power up the module 3 Supply a calibrator or simulator of the signal you wish to measure and re transm...

Page 8: ...d information about the recycling of the product please contact your local city office waste disposal service of the retail store where you purchased this product 9 DECOMMISSIONING AND DISPOSAL 8 MODU...

Reviews: