6. CONFIGURATION

6.1 

INPUT SELECTION / MEASURING SCALE

You can select the type of input by setting SW1 DIP switches placed on the side of the module.
Every type of input is matched to a certain number of beginning and end scale values which can be 
selected through SW2 DIP switches.
The following table lists possible START and END values according to the type of input selected.
The left column show the DIP-switches setting in order to select the START and END scale desired.

SW1: INPUT SELECTION

POSITIO

N

INPUT  POSITION

INPUT 

 1  2  3  4

TYPE

 1  2  3  4

TYPE

   

V

   

mA

SW2: START and END

POSITIO

N

START

POSITIO

N

END 

1  2  3

SCALE n°

4  5  6

SCALE n°

  

1

  

1

  

2

  

2

  

3

  

3

  

4

  

4

  

5

  

5

  

6

  

6

  

7

  

7

  

8

  

8

LEGENDA

ON

OFF

SW2

 DIP-switch in 

OFF

 position

(*)START and END setted in the memory by a PC or by the programming push-buttons.

Note: DIP-switches must be set while the module is powered down, otherwise,
the module may be damaged.

 

1 2 3 4 5 6 7 8



SCALE n°

Voltage

Current

START

END

START

END

  

1

(*)

(*)

(*)

(*)

  

2

0 V

100 mV

0 mA

1 mA

  

3

400 mV

200 mV

1 mA

2 mA



4

1 V

500 mV

4 mA

3 mA



5

2 V

1 V

-1 mA

4 mA



6

-5 V

5 V

-5 mA

5 mA

  

7

-10 V

10 V

-10 mA

10 mA



8

-20 V

20 V

-20 mA

20 mA

Summary of Contents for Z109UI2

Page 1: ...9 8706287 Internet site Technical assistance www seneca it support seneca it Commercial reference sales seneca it Chapter index Page 1 Preliminary warnings 2 2 Description and characteristics 2 1 Modu...

Page 2: ...d Measurement and re transmission on isolated analog output with voltage and current output DIP switch for selecting type of input START END output mode zero elevation scale inversion output type mA o...

Page 3: ...ards EN61000 6 4 electromagnetic emission in industrial environment EN61000 6 2 electromagnetic immunity in industrial environment EN61010 1 safety Notes Use with copper conductor Use in Pollution Deg...

Page 4: ...y at least 5 mm in the following cases If the panel operating temperature exceeds 45 C and at least one of the severe operating conditions exists If the panel operating temperature exceeds 35 C and at...

Page 5: ...tput 1 6 V Voltage mA output 1 6 A Generated current 3 mA output External power Supply current 4 1 6 A 5 6 ANALOG OUTPUT Electrical ratings for UL Output 10 V 20 mA Input 20 V 20 mA Operating Temp 20...

Page 6: ...e START and END scale desired SW1 INPUT SELECTION POSITIO N INPUT POSITION INPUT 1 2 3 4 TYPE 1 2 3 4 TYPE V mA SW2 START and END POSITIO N START POSITIO N END 1 2 3 SCALE n 4 5 6 SCALE n 1 1 2 2 3 3...

Page 7: ...the type of input START and END measurement which include the required beginning and end values 2 Power up the module 3 Supply a calibrator or simulator of the signal you wish to measure and re transm...

Page 8: ...d information about the recycling of the product please contact your local city office waste disposal service of the retail store where you purchased this product 9 DECOMMISSIONING AND DISPOSAL 8 MODU...

Reviews: