PROFINET Master / Serial 

 

Document code: MN67B70_ENG     Revision 1.000    Page 1 of 31

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

User Manual 

Revision 1.000 
English 

 

PROFINET Master / Serial - Converter

 

 

(Order Code: HD67B70-232-A1, HD67B70-485-A1, 

HD67B70-422-A1) 

 

for Website information:  

http://www.adfweb.com/?Product=HD67B70

    

 

for Price information: 

http://www.adfweb.com/?Price=HD67B70-232-A1

  

http://www.adfweb.com/?Price=HD67B70-485-A1

  

http://www.adfweb.com/?Price=HD67B70-422-A1

  

 

Benefits and Main Features: 

 

Triple electrical isolation 

 

Two Ethernet ports 

 

Temperature range: -40°C/+85°C (-40°F/+185°F) 

For others PROFINET Master devices, see also the following links:  

 
PROFINET Master from/to … 

www.adfweb.com?Product=HD67B45

  

(

OPC UA Server

www.adfweb.com?Product=HD67B71

  

(

Modbus Slave

www.adfweb.com?Product=HD67B72

  

(

PROFIBUS Slave

www.adfweb.com?Product=HD67B73

  

(

CAN

www.adfweb.com?Product=HD67B74

  

(

CANopen

www.adfweb.com?Product=HD67B75

  

(

DeviceNet Slave

www.adfweb.com?Product=HD67B76

  

(

Modbus TCP Slave

www.adfweb.com?Product=HD67B77

  

(

SNMP Agent

www.adfweb.com?Product=HD67B78

  

(

EtherNet/IP Slave

www.adfweb.com?Product=HD67B79

  

(

KNX

www.adfweb.com?Product=HD67B80

    

(

MQTT

www.adfweb.com?Product=HD67B81

    

(

BACnet Slave

www.adfweb.com?Product=HD67B82

    

(

IEC 61850 Server

www.adfweb.com?Product=HD67B84

  

(

Ethernet

 
Do you have an your customer protocol? 

See the following links: 

www.adfweb.com?Product=HD67003

 

 
Do you need to choose a device? do you want help? 

Ask it to the following link: 

www.adfweb.com?Cmd=helpme

 

 

User Manual 

Summary of Contents for PROFINET Master HD67B70-232-A1

Page 1: ...r devices see also the following links PROFINET Master from to www adfweb com Product HD67B45 OPC UA Server www adfweb com Product HD67B71 Modbus Slave www adfweb com Product HD67B72 PROFIBUS Slave www adfweb com Product HD67B73 CAN www adfweb com Product HD67B74 CANopen www adfweb com Product HD67B75 DeviceNet Slave www adfweb com Product HD67B76 Modbus TCP Slave www adfweb com Product HD67B77 SN...

Page 2: ... WARRANTIES AND TECHNICAL SUPPORT 31 RETURN POLICY 31 Pagina 2 di 31 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Do...

Page 3: ...cks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a pote...

Page 4: ... Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET Master Serial Document code MN67B70_ENG Revision 1 000 Page 4 of 31 EXAMPLE OF CONNECTION ...

Page 5: ...DFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET Master Serial Document code MN67B70_ENG Revision 1 000 Page 5 of 31 CONNECTION SCHEME Figure 1a Connection scheme for HD67B70 232 A1 ...

Page 6: ...Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET Master Serial Document code MN67B70_ENG Revision 1 000 Page 6 of 31 Figure 1b Connection scheme for HD67B70 485 A1 ...

Page 7: ...Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET Master Serial Document code MN67B70_ENG Revision 1 000 Page 7 of 31 Figure 1c Connection scheme for HD67B70 422 A1 ...

Page 8: ... Serial Power Supply Serial Ethernet Ethernet Power Supply Up to 4096 bytes in reading and 4096 bytes in writing Two directional information between Serial and PROFINET Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67B70 software on your PC in order to perform the following Define the p...

Page 9: ...er Serial Document code MN67B70_ENG Revision 1 000 Page 9 of 31 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax HD67B84 A1 8V 24V 12V 35V Consumption at 24V DC Device W VA HD67B70 xxx A1 4 Caution Not reverse the polarity power HD67B70 xxx A1 ...

Page 10: ...device has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second with Dip1 in On position is used for upload the Project Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specifics func...

Page 11: ...lowly 0 5Hz update in progress 3 BF bus fault red ON The Ethernet connection is defective the IP address exists several times in the network the own NameOfStation exists several times in the network no IP address has been set Flashing At least one configured AR is no longer in the data exchange OFF No errors are present Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 4 SF gro...

Page 12: ...mum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended the use of a cross cable RS232 The connection from RS232 socket to a serial port example one from a personal computer must be...

Page 13: ...sistor it is necessary to put ON dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p n 82842 2x 24AWG stranded twisted pairs conductor foil shield braid shield Tasker p n C521 1x 24AWG twisted pair conductor foil shield braid shield Tasker p n C522 2x 24A...

Page 14: ...30 91 31 User Manual PROFINET Master Serial Document code MN67B70_ENG Revision 1 000 Page 14 of 31 RS422 For terminating the RS422 line with a 120Ω resistor it is necessary to put ON dip 1 for T line and or put ON dip 2 for R line like in figure The maximum length of the cable should be 1200m 4000 feet ...

Page 15: ... use the available software that runs with Windows called SW67B70 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 10 32 64bit When launching the SW67B70 the window below appears Fig 2 Note It is necessary to have inst...

Page 16: ...contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable PROFINET Master Serial Converter in order to configure another device in the same manner it is necessary to maintain the folder and all its contents To clone a project in order to obtain a different version of the project it is sufficient to duplicate t...

Page 17: ...ere is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67B70 check au...

Page 18: ...e 39 0438 30 91 31 User Manual PROFINET Master Serial Document code MN67B70_ENG Revision 1 000 Page 18 of 31 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the tables contained in the different sections of the software ...

Page 19: ... the IP address for PROFINET side of the converter is defined In the fields SubNet Mask the SubNet Mask for PROFINET side of the converter is defined In the fields Gateway the default gateway of the net is defined This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field Name of Station the name of the PROFINET node is defined T...

Page 20: ...s Present in Network window PROFINET ACCESS By Pressing the PROFINET Access button from the main window for SW67B70 Fig 2 the window Definition of PROFINET Devices Present in Network appears Fig 4 This section is used to define the list of the PROFINET slaves to read write with the PROFINET Master It is possible to add the PROFINET slaves from the hardware catalog If a new device will be connected...

Page 21: ...IP Address of the PROFINET slave is defined If the field Automatic new session when StationProblemIndicator is active is checked the converter will restart the PROFINET communication when the error indicator in the slave is present In the field Update Time ms the delay used for IO communication is defined In the field Answer TimeOut the allowed number of cycles without response from the slave is d...

Page 22: ...evice appears Fig 5 In the main table it is possible to import the Modules of the PROFINET device in use In the properties below it is possible to set the parameters of the slave These options depends on the slave in use refer to the manual of the PROFINET device The means of the checkboxes inside the table are If the field Map Only Data is checked only the data of the modules are mapped into the ...

Page 23: ...n ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip2 of Dip Switch A in OFF position Turn ON the device If you know the actual IP address of the device you have to use this procedure Turn ON the Device with the Ethernet ca...

Page 24: ...AN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program more than one device using the UDP Update you have to cancel the ARP table every time you connect a new device on Ethernet For do this you have to launch the Command Pr...

Page 25: ...me simple commands over serial port Reading data by PROFINET slave this command allows to read all the data from a specific PROFINET slave Request Byte Number Description 1 R 0x52 2 0x2E 3 5 PROFINET slave to read 000 009 decimal Response Byte Number Description 1 D 0x44 2 0x3A 3 n 2 Output byte of PROFINET slave two chars for each byte n number of Output bytes of the slave The number of PROFINET ...

Page 26: ...iption 1 R 0x52 2 0x2E 3 5 PROFINET slave to read 000 009 decimal 6 0x2E 7 9 PROFINET module to read decimal Response Byte Number Description 1 D 0x44 2 0x3A 3 n 2 Output byte of PROFINET slave two chars for each byte n number of Output bytes of the selected module The number of PROFINET slave depends on the order with which they are defined in the PROFINET Access section of SW67B70 The number of ...

Page 27: ...PROFINET slave to read 000 009 decimal 6 0x2E 7 9 Starting output byte to write decimal 10 0x2E 11 13 Number of bytes to write decimal 14 0x3D 15 n 15 Data to write hex n number of bytes defined in bytes 11 12 13 of the command Response Byte Number Description 1 D 0x44 2 0x3A 3 n 2 Output byte of PROFINET two chars for each byte n number of Input bytes of the slave The number of PROFINET slave dep...

Page 28: ...m Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET Master Serial Document code MN67B70_ENG Revision 1 000 Page 28 of 31 MECHANICAL DIMENSIONS Figure 8 Mechanical dimensions scheme for HD67B70 xxx A1 ...

Page 29: ...e 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Serial port 232 RS232 485 RS485 422 RS422 Device Family HD67B70 PROFINET Master Serial Converter Order Code HD67B70 232 A1 PROFINET Master Serial Converter Serial port RS232 Order Code HD67B70 485 A1 PROFINET Master Serial Converter Serial port RS485 Order Code HD67B70 422 A1 PROFINET Master Serial Converter Serial port RS422 ACCESSOR...

Page 30: ...n countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human he...

Page 31: ...to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve mo...

Reviews: