background image

ENGLISH 5/7

6 ELECTRICAL CONNECTIONS 

Power OFF the module before connecting the inputs and outputs.

 

In order to

 

satisfy the electromagnetic compliance requirements: 

- Use shielded cables for the signals transmission;
- Connect the shield to a preferential ground for devices;
- Space the shielded cables from other cables used for power installations (transformers, inverters,
motors, induction ovens, etc...);

Power supply 

The power supply must be connected to terminals 2 and 3. The supply voltage 
must be between 11 and 40V

C

 (any polarity), or between 19 and 28 V

A

The upper limits must not be exceeded in order  to avoid serious damage to the 
module. 

The power supply source must be protected from any malfunctions of the module through 
appropriately sized safety fuse.

 

Analog input 1 and 2

Voltage

 

Current active sensor (4 wires)  Current passive sensor

 

(2 wires) 

The Z-TWS11 module has 
two software voltage or 
current configurable analog 
inputs. 
For the configuration 
software you can read the 
user manual 

Connection of COM4 - RS485 serial port (SW2=OFF)

Z-TWS11 has a serial port configurable through the SW2 Switch.
If the switch SW2 is set to   OFF position,
then the RS485 serial port (COM4) is available to terminals 10-11-12.
The picture shows how to make the connection.

Connection of COM4 - RS232 serial port (SW2=ON)

 

Z-TWS11 has a serial port configurable through the SW2 Switch.
If the switch SW2 is set to   ON position,
then the RS232 serial port (COM4) is available to terminals 10-11-12.
The picture shows how to make the connection.

Inserting the micro SD card 

Inserting the 

MicroSD or the microSHDC, into the side slot. max. 32 GB. 

Push-push connector for insertion and removal. 

RJ45 ETHERNET and USB On The Go connections

 

Ethernet, 

Inserting 

the RJ45 connector 

into the Ethernet socket RJ45 

10/100 BaseT with autoswitch, make sure that the connector is securely 
latched, else remove before the RJ45 protective rubber. 

For further information, refer to the USER MANUAL

 

USB, 

Insert the

 micro USB plug into the micro USB side socket

 

MI00367

-3

-E 

Summary of Contents for Z-TWS11

Page 1: ... PANEL MODULE LAYOUT 11 DECOMMISSIONING AND DISPOSAL Factory Seneca srl Headquarters Via Austria 26 35127 Z I Padova IT Phone 39 049 8705355 8705355 Fax 39 049 8706287 Site www seneca it Mail Technical support support seneca it Product Informations sales seneca it This document is property of SENECA srl Duplication and reproduction are forbidden if not authorized The content of the present documen...

Page 2: ...INSTRUCTIONS It is forbidden block the ventilation slots with any object It is forbidden to install the module near heat sources Warning Do not turn off the Z TWS 11 module while writing the micro SD card so as not to corrupt the file system For data logging applications on micro SD card you must use an external UPS 3 GENERAL SPECIFICATIONS Multifunction and multi protocol control unit Module conf...

Page 3: ...32GByte Power supply Voltage 11 40 VC 19 28 VA 50 60 Hz Power consumption Typical 1 5 W 24V max 2 W Environmental conditions Temperature From 10 to 50 C Humidity 30 90 not condensing Storage temperature From 20 to 85 C Protection degree IP20 Overall dimensions Case Dimensions Weight L 100 mm H 111 mm W 17 5 mm 104 gr Case PA6 black Insulations Standards The instrument complies with the following s...

Page 4: ... of the IDC10 rear connector as shown in fig 1a Removal from the IEC EN 60715 guide As shown in figure 1b 1 Move outwards the two hooks on the side of the module with the help of a screwdriver 2 Extract the module from the guide Use of Z PC DINAL2 17 5 accessory If Z PC DINAL2 17 5 accessory is used the power supply and communication signals may be provided by the terminals block into the DIN rail...

Page 5: ...gurable analog inputs For the configuration software you can read the user manual Connection of COM4 RS485 serial port SW2 OFF Z TWS11 has a serial port configurable through the SW2 Switch If the switch SW2 is set to OFF position then the RS485 serial port COM4 is available to terminals 10 11 12 The picture shows how to make the connection Connection of COM4 RS232 serial port SW2 ON Z TWS11 has a ...

Page 6: ...W1 KEY Turn off the Z TWS11 module and set to ON all eight DIP switches SW1 Turn on the Z TWS11 module and then wait 10 seconds Turn off the Z TWS11 module and set to OFF all eight DIP switches SW1 ON 1 OFF 0 SW2 Switch setting RS232 or RS485 configuration on terminals 10 11 12 serial port COM 4 SW2 KEY RS232 ON 1 RS485 OFF 0 8 LED SIGNALING ON THE FRONTAL PANEL LED STATUS LEDs meaning Tx1 Red Bli...

Page 7: ... the product is suitably discarded will avoid potential negative impacts on the environment and human health that could be caused by non compliant product disposal Material recycling will contribute to the preservation of natural resources To receive further information please contact your local waste disposal service center or product dealer For the Z TWS11 configuration use the EASY SETUP softwa...