1 PRELIMINARY WARNINGS 

Before  performing  any  operation,  it  is  mandatory  to  read  and  understood  in  full  the 
contents  of  this  installation  manual.  The  module  may  only  be  used  by  qualified  and 
skilled  technicians  in  the  field  of  electric  installations.  Specific  documentation  is 
available at website: 

www.seneca.it/products/z-tws11

 

Only the Manufacturer is authorized to repair the module or to replace damaged parts. 
The  product  is  susceptible  to  electrostatic  discharge,  take  appropriate 
countermeasures during any operation

The user must comply of the safety instructions in this installation manual, the country-
specific  installation  standards  and  all  prevailing  safety  regulations  and  accident 
prevention  rules.  No  warranty  is  guaranteed  in  connection  with  faults  resulting  from 
improper use, from modifications or repairs carried out by Manufacturer-unauthorized 
personnel on the device, or if the content of this user Manual is not followed.

 

2 PRELIMINARY INSTRUCTIONS 

It is forbidden 

block the ventilation slots with any object.

 

It is forbidden to install the module near heat sources. 

Warning:

 

Do not turn off the Z-TWS 11 module while writing the micro SD card so as not to 

corrupt the file system.

 

For data logging applications on micro SD card, you must use an external UPS.

 

3 GENERAL SPECIFICATIONS 

Multifunction and multi-protocol control unit

.

Module configuration and firmware upgrade through Web-server

Integrated Straton PLC.

Insulation 1500 V

A

 between power supply and other circuits

Easy power supply and serial communication wiring through Seneca IEC EN 60715 DIN rail bus

Removable terminals with section of 2.5 mm

2

.

LEDs signaling: power on, micro SD card access, Ethernet link and activity, RS485 Rx and Tx

2 analog inputs at 16 bit configurables for voltage or current.

1 Ethernet RJ45 front. 10/100 Mbps, 1 RS485 Port, 1 RS232/RS485 Port, 1  Micro USB

Supported System Protocols: 

FTP client, SMTP client, http, ModBUS TCP, ModBUS RTU

RAM retentive variables max.= 4 kByte (Fe-RAM 

technology with limitless writes

)

Micro SD additional storage memory up to 32 GB

ARM Processor 120 MHz, 32 bit, Real Time multitasking O.S.

MI00367

-3

-E 

Summary of Contents for Z-TWS11

Page 1: ... PANEL MODULE LAYOUT 11 DECOMMISSIONING AND DISPOSAL Factory Seneca srl Headquarters Via Austria 26 35127 Z I Padova IT Phone 39 049 8705355 8705355 Fax 39 049 8706287 Site www seneca it Mail Technical support support seneca it Product Informations sales seneca it This document is property of SENECA srl Duplication and reproduction are forbidden if not authorized The content of the present documen...

Page 2: ...INSTRUCTIONS It is forbidden block the ventilation slots with any object It is forbidden to install the module near heat sources Warning Do not turn off the Z TWS 11 module while writing the micro SD card so as not to corrupt the file system For data logging applications on micro SD card you must use an external UPS 3 GENERAL SPECIFICATIONS Multifunction and multi protocol control unit Module conf...

Page 3: ...32GByte Power supply Voltage 11 40 VC 19 28 VA 50 60 Hz Power consumption Typical 1 5 W 24V max 2 W Environmental conditions Temperature From 10 to 50 C Humidity 30 90 not condensing Storage temperature From 20 to 85 C Protection degree IP20 Overall dimensions Case Dimensions Weight L 100 mm H 111 mm W 17 5 mm 104 gr Case PA6 black Insulations Standards The instrument complies with the following s...

Page 4: ... of the IDC10 rear connector as shown in fig 1a Removal from the IEC EN 60715 guide As shown in figure 1b 1 Move outwards the two hooks on the side of the module with the help of a screwdriver 2 Extract the module from the guide Use of Z PC DINAL2 17 5 accessory If Z PC DINAL2 17 5 accessory is used the power supply and communication signals may be provided by the terminals block into the DIN rail...

Page 5: ...gurable analog inputs For the configuration software you can read the user manual Connection of COM4 RS485 serial port SW2 OFF Z TWS11 has a serial port configurable through the SW2 Switch If the switch SW2 is set to OFF position then the RS485 serial port COM4 is available to terminals 10 11 12 The picture shows how to make the connection Connection of COM4 RS232 serial port SW2 ON Z TWS11 has a ...

Page 6: ...W1 KEY Turn off the Z TWS11 module and set to ON all eight DIP switches SW1 Turn on the Z TWS11 module and then wait 10 seconds Turn off the Z TWS11 module and set to OFF all eight DIP switches SW1 ON 1 OFF 0 SW2 Switch setting RS232 or RS485 configuration on terminals 10 11 12 serial port COM 4 SW2 KEY RS232 ON 1 RS485 OFF 0 8 LED SIGNALING ON THE FRONTAL PANEL LED STATUS LEDs meaning Tx1 Red Bli...

Page 7: ... the product is suitably discarded will avoid potential negative impacts on the environment and human health that could be caused by non compliant product disposal Material recycling will contribute to the preservation of natural resources To receive further information please contact your local waste disposal service center or product dealer For the Z TWS11 configuration use the EASY SETUP softwa...