background image

6/8

COMMUNICATION PORT IDENTIFICATION

RJ45 Ethernet port (on front)

Z-KEY-wifi has an Ethernet 10/100 port with RJ45 connector on 

the module front.

Micro USB port

Z-KEY-wifi has a USB connector that can be used as a 

configuration port via the Easy Setup software.

Micro SD card slot

Z-KEY-WIFI has a micro SD card slot on the side of the case.

To insert the SD card in the corresponding slot, make sure the 

metal contacts are facing right (as shown in the side figure).

The SD card can be of any capacity.

To activate the first configuration Access Point function, follow the following steps:

1.  Press the side button of the Z-KEY-WIFI;

2.  Keeping the button pressed, power the instrument;

3.  Release the button after 5 seconds.

Through this procedure, the device switches to first configuration AP mode without password to enter the 

parameters of the WIFI. The AP led will flash.

ACCESS POINT: FIRST CONFIGURATION

OPERATION IN ACCESS POINT MODE

In this mode, a device can function as an Access Point and accept the connection of up to 6 station devices 

without the aid of an external Access Point.

This configuration can be activated from the web server.

OPERATION IN STATION MODE

In this mode, the device can connect to an existing Access Point. This function can be activated from the web 

server. 

Summary of Contents for Z-KEY-WIFI

Page 1: ...Serial Device Server with WIFI SENECA s r l Via Austria 26 35127 PADOVA ITALY Tel 39 049 8705355 8705359 Fax 39 049 8706287 For manuals in other languages and the configuration software visit www sene...

Page 2: ...er countries with recycling The symbol on the product or its packaging shows the product must be surrendered to a collection centre authorized to recycle electrical and electronic waste The module mus...

Page 3: ...icroSD card slot POWER SUPPLY Voltage 11 40 Vdc 19 28 Vac 50 60 Hz Absorption Typical 2 W 24Vdc Max 3 W 24 Vac WIFI IEEE 801 11 b g n Security WEP WPA WPA 2 COMMUNICATION PORTS RS242 or RS485 switchab...

Page 4: ...has a micro USB connector on the front panel and can be configured using applications and or software programs The USB serial port uses the following communication parameters 115200 8 N 1 The USB comm...

Page 5: ...vide the module with power supply as an alternative to the connection using the Z PC DINx bus The power supply voltage must remain in the range of either 19 and 40V Vdc any polarity or 19 and 28V Vac...

Page 6: ...ess Point function follow the following steps 1 Press the side button of the Z KEY WIFI 2 Keeping the button pressed power the instrument 3 Release the button after 5 seconds Through this procedure th...

Page 7: ...GURATION ACCESSORIES CODE DESCRIPTION KIT USB Programming KIT USB CD cable MICRO SD Micro SD Flash card CE RJ45 RJ45 R 1 5 m Ethernet cable CS DB9M MEF 1012 Z KEY RS232 DB9 serial connection cable Z P...

Page 8: ......

Reviews: