User Manual
T201DCH50/100/300-M
ALL RIGHTS RESERVED. NO PART OF THIS PUBLICATION MAY
Doc. MI004730-EN
Rev. 1.0.2
Page 7
DIP SWITCH CONFIGURATION
3.1.
Loading configuration from flash
If ALL Dip Switch 1…8 are OFF, the device use the Flash configuration (you must use the Easy Setup
Software for configure)
Load
Configuration
DIP1
DIP2
DIP3
DIP4
DIP5
DIP6
DIP7
DIP8
FROM FLASH
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
3.2.
Setting the Modbus RTU Station Address
Dip Switch 1..4 are using for configure the Modbus RTU Station Address:
Modbus RTU
Address
DIP1
DIP2
DIP3
DIP4
1
ON
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
3
ON
ON
OFF
OFF
4
OFF
OFF
ON
OFF
5
ON
OFF
ON
OFF
6
OFF
ON
ON
OFF
7
ON
ON
ON
OFF
8
OFF
OFF
OFF
ON
9
ON
OFF
OFF
ON
10
OFF
ON
OFF
ON
11
ON
ON
OFF
ON
12
OFF
OFF
ON
ON
13
ON
OFF
ON
ON
14
OFF
ON
ON
ON
15
ON
ON
ON
ON
BE REPRODUCED WITHOUT PRIOR PERMISSION.