background image

MI00096 -E

3

ENGLISH - 8/8

LED indications on the front

LED (Red)

Meaning

Flashing

Steady light

Internal fault.

Note: in case of internal fault, the output will stay at null value.

Input or output out-of-range limiter device triggered or input
saturation.

Disposal of Electrical & Electronic Equipment (Applicable throughout the European Union and other
European countries with separate collection programs)
This symbol, found on your product or on its packaging, indicates that this product should not be treated as
household waste when you wish to dispose of it. Instead, it should be handed over to an applicable
collection point for the recycling of electrical and electronic equipment. By ensuring this product is
disposed of correctly, you will help prevent potential negative consequences to the environment and
human health, which could otherwise be caused by inappropriate disposal of this product. The recycling of
materials will help to conserve natural resources. For more detailed information about the recycling of this
product, please contact your local city office, waste disposal service or thè retail store where you
purchased this product.

SENECA s.r.l.

Via Austria, 26 - 35127  -  PADOVA - ITALY
Tel.  +39.049.8705355 - 8705359  -  Fax +39.049.8706287
e-mail: [email protected]  -  www.seneca.it

This document is property of SENECA srl. Duplication and reprodution are forbidden, if not authorized. Contents of the
present documentation refers to products and technologies described in it. All technical data contained in the document
may be modified without prior notice Content of this documentation is subject to periodical revision.

Summary of Contents for K109UI

Page 1: ...mm DIN driver power supply available by bus quick fit couplings by spring type terminals 3 point insulation onsite configuration by DIP switch Technical Features Power supply Consumption 19 2 30 Vdc M...

Page 2: ...of range limiter device triggered or input saturation Internal fault Spring terminals 0 2 2 5 mm 2 8 mm EN50081 2 electromagnetic emission industrial surroundings EN50082 2 electromagnetic immunity i...

Page 3: ...Y OUTPUT INPUT 19 2 30 Vdc P 500 mW V I Range 150 650 C Load R 500 R 2 k Test Voltage 1 5 kV 50 Hz 1 min Amb Temp 20 65 C m W W V I 1 Attach the module in the upper part of the rail 2 Press the module...

Page 4: ...esent No None 0 20 mA 5 limit SETTING OF THE DIP SWITCHES Factory setting Note for all following tables The indication indicates that the DIP switch is set in Position 1 ON No indication is provided w...

Page 5: ...5 25 Vdc 0 75 Vdc 1 5 Vdc 0 Vdc 0 20 mA 4 20 mA 20 0 mA 5 20 4 mA 5 0 10 Vdc 0 5 Vdc 1 5 Vdc 2 10 Vdc 5 These are inverse output ranges that are useful whenever the linearisation applied is incompatib...

Page 6: ...wer supply to the modules via bus connector in this way eliminating the need to connect power supply to each module The bus can be supplied from any of the modules the total absorption of the bus must...

Page 7: ...turn Current input Terminal 3 Current input Terminal 4 Return Output Voltage connection Current connection applied current The use of shield cables is recommended for the electronic connections 1 5 6...

Page 8: ...ct is disposed of correctly you will help prevent potential negative consequences to the environment and humanhealth whichcouldotherwisebecausedbyinappropriatedisposalofthisproduct Therecyclingof mate...

Reviews: