Note: in case of internal fault, the output will stay at null value.

LED indications on the front

LED (Red)

Meaning

Fast Flashing

Slow Flashing

Steady light

Internal fault

DIP-switch setting not allowed

Input or output out-of-range limiter device triggered or input
saturation.

Examples of Active Input Connections

1

5

6

7

8

2

3

4

POWER
SUPPLY

AUX
SUPPLY

OUTPUT

INPUT

2 wires Connections

Active Current Input.

3

4

1

2

3

4

1

2

Active Input provided from a 4 wires sensor,
supplied by the Auxiliary Power Supply.

Sensor

Supply -

IN +

IN -

Disposal of Electrical & Electronic Equipment (Applicable throughout the European Union and other
European countries with separate collection programs)
This symbol, found on your product or on its packaging, indicates that this product should not be treated as
household waste when you wish to dispose of it. Instead, it should be handed over to an applicable
collection point for the recycling of electrical and electronic equipment. By ensuring this product is
disposed of correctly, you will help prevent potential negative consequences to the environment and
human health, which could otherwise be caused by inappropriate disposal of this product. The recycling of
materials will help to conserve natural resources. For more detailed information about the recycling of this
product, please contact your local city office, waste disposal service or thè retail store where you
purchased this product.

SENECA s.r.l.

Via Austria, 26 - 35127  -  PADOVA - ITALY
Tel.  +39.049.8705355 - 8705359  -  Fax +39.049.8706287
e-mail: [email protected]  -  www.seneca.it

This document is property of SENECA srl. Duplication and reprodution are forbidden, if not authorized. Contents of the
present documentation refers to products and technologies described in it. All technical data contained in the document
may be modified without prior notice Content of this documentation is subject to periodical revision.

Summary of Contents for K109S

Page 1: ...is also characterised by its extremely compact size coupling to 35 mm DIN rail power supply available by bus quick fit couplings by spring type terminals onsite configuration by DIP switch General Des...

Page 2: ...ng terminals 0 2 2 5 mm 2 EN61000 6 4 2002 electromagnetic emission industrial surroundings EN61000 6 2 2005 electromagnetic immunity industrial surroundings EN61010 1 2001 safety All the circuits mus...

Page 3: ...le in the rail Removing the module from the rail Using the K BUS connector 1 Compose the K BUS connectors as required in order to obtain the number of positions necessary each K BUS permits the insert...

Page 4: ...resent No None 0 20 mA 5 limit SETTING OF THE DIP SWITCHES Factory setting Note for all following tables The indication indicates that the DIP switch is set in Position 1 ON No indication is provided...

Page 5: ...A 4 20 mA 20 0 mA 5 20 4 mA 5 0 10 Vdc 0 5 Vdc 1 5 Vdc 2 10 Vdc 5 These are inverse output ranges that are useful whenever the linearisation applied is incompatible with the inversion of the input INP...

Page 6: ...ing the need to connect power supply to each module The bus can be supplied from any of the modules the total absorption of the bus must be less than 400 mA Higher absorption values can damage the mod...

Page 7: ...f the provided voltage is indipendent from the one supplyed through 7 and 8 terminals Output Voltage connection Current connection applied current The use of shield cables is recommended for the elect...

Page 8: ...e of it Instead it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prev...

Reviews: