Technical Features

The K109S instrument is a V - mA converter with 4-point galvanic insulation designed for
industrial standard voltage or current signals with passive input, active output and
auxiliary supply.
Analog/digital conversion takes place at 14 bit on every input range.
The instrument also provides the following functions:

Auxiliary Supply, completely floating, isolated from the other ports, with voltage unrelated

to the input power supply.

Current or voltage input.
Programmable rejection for 50 or 60 Hz mains frequency.

Additional reading stabilisation filter.

Inversion of the input and inverted output scales
Input Out-of-Range programmable to 2.5% or 5.0%
SQRT function.
Linearisation for horizontal cylindrical tanks.

The module is also characterised by its extremely compact size, coupling to 35 mm DIN
rail, power supply available by bus, quick fit couplings by spring-type terminals, onsite
configuration by DIP-switch.

General Description

19,2..30 Vdc
-max 23 mA at  24 Vdc  ( with output at 20 mA and
auxiliary supply not used)
-max 45 mA at  24 Vdc  ( with output at  21 mA
and auxiliary supply at 21 mA )
<  500 mW.

0..10 V, 2..10 V, 0..5 V, 1..5 V, Input Impedance :
110 k

Ω

0..20 mA, 4..20 mA, Input Impedance : 35

Ω

± 2,5 o ± 5% depending on settings (see section
Inputs-Outputs Limits)
0..5 Vdc, 1..5 Vdc, 0..10 Vdc e 2..10 Vdc
Minima load resistance di carico  2 K

Ω

0..20 mA, 4..20 mA, 20..0 mA, 20..4 mA
Maximum load resistance  500

Ω

Fixed (see section

)

Input-Output Limits

approximately  25 mA

Digital, 32 bit floating-point calculation
14 bit on every input range

Voltage: 17..21 Vdc
Current: 0..25 mA.

Power Supply :
Consumtion :

Dissipation :

Voltage Input :

Current Input:
Permissible max. Input Out-of-
Range:

Voltage Output :

Current Output :

Permissible max. Output Out-of-
Range :
Current output protection :

Processing :
ADC :

Auxiliary Supply:

Summary of Contents for K109S

Page 1: ...is also characterised by its extremely compact size coupling to 35 mm DIN rail power supply available by bus quick fit couplings by spring type terminals onsite configuration by DIP switch General Des...

Page 2: ...ng terminals 0 2 2 5 mm 2 EN61000 6 4 2002 electromagnetic emission industrial surroundings EN61000 6 2 2005 electromagnetic immunity industrial surroundings EN61010 1 2001 safety All the circuits mus...

Page 3: ...le in the rail Removing the module from the rail Using the K BUS connector 1 Compose the K BUS connectors as required in order to obtain the number of positions necessary each K BUS permits the insert...

Page 4: ...resent No None 0 20 mA 5 limit SETTING OF THE DIP SWITCHES Factory setting Note for all following tables The indication indicates that the DIP switch is set in Position 1 ON No indication is provided...

Page 5: ...A 4 20 mA 20 0 mA 5 20 4 mA 5 0 10 Vdc 0 5 Vdc 1 5 Vdc 2 10 Vdc 5 These are inverse output ranges that are useful whenever the linearisation applied is incompatible with the inversion of the input INP...

Page 6: ...ing the need to connect power supply to each module The bus can be supplied from any of the modules the total absorption of the bus must be less than 400 mA Higher absorption values can damage the mod...

Page 7: ...f the provided voltage is indipendent from the one supplyed through 7 and 8 terminals Output Voltage connection Current connection applied current The use of shield cables is recommended for the elect...

Page 8: ...e of it Instead it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prev...

Reviews: