10-90% response :

Transmission :
Max. transmission error

:

(1)

Resolution :
Thermal drift :
SQRT error

:

(2) (3)

Linearisation error Cylindrical
tank

:

(2)

50 Hz : max 41 ms without filter and 88 ms with filter;
60 Hz : max 35 ms without filter and 74 ms with filter.
Digital Optical
0.08% of the f.s. value for mA or 5 V output
0.07% of the f.s. value for 10 V output
1 mV for voltage output, 2 A for current output

m

Lower than 120 ppm/K
in the range 1..100%: floating point 32 bit

0,05%

MI00102 -E

4

ENGLISH - 2/8

Insulation Voltage :
Protection Index :
Operating Conditions :

Storage Temperature :
LED Signalling :

Connections :
Conductor Section :
Wire stripping :

Standards :

Dimensions, Weight :

1,5 KV  between each group of ports
IP20
Temperature  -20..+65 °C
Humidity  10..90 %  at  40°C  (non-condensing)
Altitudine 2000 slm
-40..+85 °C
Input or output out-of-range limiter device triggered or
input saturation    Internal fault. Wrong DIP-switches

.

settings.
Spring terminals
0,2..2,5 mm

2

EN61000-6-4/2002 (electromagnetic emission, industrial surroundings)
EN61000-6-2/2005 (electromagnetic immunity, industrial surroundings)
EN61010-1/2001 (safety)
All the circuits must be provided with double insulation from the circuits
under dangerous voltage. The power supply transformer must be built
to compliance with  EN60742: “Insulation transformers and Safety
transformers”.
Notes:
- Use with copper conductor.
- Use in Pollution Degree 2 Environment .
- Power Supply must be Class 2.
- When supplied by an Isolated Limited Voltage/Limited

Current power supply a fuse rated max 2.5 A shall be
installed in the field.

6,2 x 93,1 x 102,5 mm, 46 g.

Box :

PBT (black colour)

(1)

No linearisation function enabled.

(2)

Linearisation functions operate only in the 0..100% rated range, whereas for the under-

range and the over-range, the input signal is transferred without any alteration (G=1).
Continuity and monotonic quality of transfer are guaranteed throughout the entire range of
measurement.

(3)

In the 0..1% range, the function is linear with gain G=10 in order to avoid over-

amplification of the noise.

Summary of Contents for K109S

Page 1: ...is also characterised by its extremely compact size coupling to 35 mm DIN rail power supply available by bus quick fit couplings by spring type terminals onsite configuration by DIP switch General Des...

Page 2: ...ng terminals 0 2 2 5 mm 2 EN61000 6 4 2002 electromagnetic emission industrial surroundings EN61000 6 2 2005 electromagnetic immunity industrial surroundings EN61010 1 2001 safety All the circuits mus...

Page 3: ...le in the rail Removing the module from the rail Using the K BUS connector 1 Compose the K BUS connectors as required in order to obtain the number of positions necessary each K BUS permits the insert...

Page 4: ...resent No None 0 20 mA 5 limit SETTING OF THE DIP SWITCHES Factory setting Note for all following tables The indication indicates that the DIP switch is set in Position 1 ON No indication is provided...

Page 5: ...A 4 20 mA 20 0 mA 5 20 4 mA 5 0 10 Vdc 0 5 Vdc 1 5 Vdc 2 10 Vdc 5 These are inverse output ranges that are useful whenever the linearisation applied is incompatible with the inversion of the input INP...

Page 6: ...ing the need to connect power supply to each module The bus can be supplied from any of the modules the total absorption of the bus must be less than 400 mA Higher absorption values can damage the mod...

Page 7: ...f the provided voltage is indipendent from the one supplyed through 7 and 8 terminals Output Voltage connection Current connection applied current The use of shield cables is recommended for the elect...

Page 8: ...e of it Instead it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prev...