17
TD140-038.11 | Version 1.1 | 22 March 2019
4.1.2 Front display operation
The different control elements on the front display are described as follows; Also an overview is provided on how you can activate
or inactivate your SENECO.Home Li via the front display.
Control element
Description
OK
ESC
Passive
Charge
Discharge
Error
The front display shows the status, IP address, battery voltage, charging and discharg
-
ing current and the PV output. (see Chapter 4.1.1 Front display indicator, page 16).
OK
ESC
Passive
Charge
Discharge
Error
OK
ESC
Passive
Charge
Discharge
Error
Navigation:
Display lights are activated.
So far, no other navigation keys functions.
OK
ESC
Passive
Charge
Discharge
Malfunction
OK
ESC
Passive
Charge
Discharge
Malfunction
Switching on:
Keep the On/Off button pressed for several seconds.
The display shows “Switch on?”.
The SENEC.Home Li now switches the SENEC.Inverter on.
Confirm with "OK".
OK
ESC
Passive
Charge
Discharge
Malfunction
OK
ESC
Passive
Charge
Discharge
Malfunction
Switching off:
Keep the On/Off button pressed for several seconds.
The display shows “Switch off?”.
Press "OK" within 15 seconds
The SENEC.Home Li now switches the SENEC.Inverter off.
The status changes to "Switched off".
During disconnection, an option is provided to switch the system with its modules
and battery inverter into a passive state. The system is out of operation.
OK
ESC
Passive
Charge
Discharge
Error
Escape:
So far, the escape key has no function.
4.2 Switching off the battery during prolonged non-utilisation
Even with a disconnected DC insulating switch, while the house circuit breaker is switched on ("Standby" operating mode), some
current flows from the battery modules. An emergency charge can be performed via the grid. Disconnect the complete system
from the mains to prevent deep discharge during a prolonged period of non-usage (period > 3 months, with previous full charge).
1.
Inactivate the battery module with the "Switch off" function (see Chapter 4.1.2 Front display operation, page 17).
The MCU shuts down the battery module.
2. Inactivate the B 16 A fuse of the domestic grid.