9
Doc# 2016-25-05 Rev F Technical Support 678-208-3087 Ext #1 Airtext Installation Manual
Installation Material Required but Not Supplied
Airtext units are intended for use with standard aviation accessories. The following items are required for
installation but not supplied:
1.
Airtext™ Application
2.
Wire (MIL-W-22759/20 or equivalent)
NOTE
Extra care must be taken to adequately support and protect the wiring due to its thin insulation.
3. Shielded wire (MIL-C-27500 cable utilizing M22759/20 wire (TG) or ETFE jacket (14), or
equivalent)
4. Aircraft hardware for installation, including #6 screws, nuts / nut plates, washers, and rivets
5. Bonding strap hardware
NOTE
In order to reduce HIRF susceptibility for LRUs interfaced to Airtext, it is recommended to include a
bonding strap on Airtext router. This bonding strap is not required per Airtext STC. However, certain
STCs may require it. If applicable, please reference your installation’s STC documentation for further
installation requirements.
6. Push/pull (manually resettable) circuit breaker
7. Tie wraps or lacing cord
8. Ring terminals (MS25036 or equivalent)
9. Shield terminators (MIL-S-83519 or equivalent)
10. Silicon fusion tape (Send Solutions P/N 700-00022-100 or equivalent)
11. Compatible portable electronic device (PED)
Special Tools Required
Pin Contact Numbers
Wire Gauge
DB 25 – pin Contacts
20-24 AWG
Send Solutions P/N
460-00005-000
Military P/N
M39029/7-357