UPS Web/SNMP Card

 

UPSLink 

 
 
 

 

 

User Guide 

 

 
 
 

 

Version 2.2.1 

 

2003-07-09 

Summary of Contents for UPSLink 100

Page 1: ...1 UPS Web SNMP Card UPSLink User Guide Version 2 2 1 2003 07 09...

Page 2: ...oration Notice to Users Proper back up systems and necessary safety devices should be utilized to protect against injury death or property damage due to system failure Such protection is the responsib...

Page 3: ...mber Description 2003 04 30 v 2 0 0 written by UIS 2003 05 02 v 2 0 1 revise candidate by KCY 2003 05 13 v 2 0 2 revised done by KCY 2003 05 26 v 2 1 1 revised by UIS with firmware upgrade to 2 1 0 20...

Page 4: ...2 Using Telnet 15 2 4 Accessing web Interface 16 3 UPS management 18 3 1 UPS information 18 3 2 UPS status 19 3 3 UPS graphics overall 19 3 4 UPS graphics gauge 20 3 5 UPS configuration 21 3 6 UPS con...

Page 5: ...39 6 2 System log configuration 39 7 System administration 41 7 1 User administration 41 7 2 Device name configuration 43 7 3 Language 44 7 4 Date and time settings 44 7 5 Factory default reset 45 7 6...

Page 6: ...tion in each page Secure management The UPSLink has many features regarding secure management of the device like as user ID and Password authentication configurable access control for Web or Telnet by...

Page 7: ...7 1 2 Package check list UPSLink100 110 230 VDC power adaptor Serial console cable CD ROM including software and manuals...

Page 8: ...LAN port Protocols ARP IP ICMP TCP Telnet DNS Dynamic DNS HTTP HTTPS SMTP SMTP with Authentication pop before SMTP DHCP client NTP PPPoE SNMP v1 v2c MIB MIB II RFC 1213 UPS MIB RFC 1628 User ID Passwo...

Page 9: ...MAC address can be found on the bottom of the original package Host A user s computer connected to the network Internet protocol specifications define host as any computer that has full two way acces...

Page 10: ...Control Protocol DHCP Dynamic Host Configuration Protocol SMTP Simple Mail Transfer Protocol FTP File Transfer Protocol PPP Point To Point Protocol PPPoE Point To Point Protocol over Ethernet HTTP Hy...

Page 11: ...ms are required to get started A power adaptor and a cable included in the package A console cables included in the package An Ethernet cable A PC with Network Interface Card hereafter NIC and or a RS...

Page 12: ...nnect the UPSLink to the equipment for initial testing Connect a power source to the UPSLink Connect the UPSLink to an Ethernet hub or switch Connect the UPS 2 2 1 Connecting power Connect the power c...

Page 13: ...nt network connection is 10Base T Figure 2 3 Connecting a network cable to the UPSLink 2 2 3 Connecting UPS to the UPSLink Connect both ends of the console cable to the UPSLink serial port and the ser...

Page 14: ...SLink using conventional web browsers such as Internet Explorer or Netscape Navigator The UPSLink requires user authentication for all the above methods 2 3 1 Using system console 1 Switch Data Consol...

Page 15: ...s select menu 6 Save changes All the configuration change will be effective after selecting the menu 7 Exit and apply changes or 8 Exit and reboot 2 3 2 Using Telnet The IP address of the UPSLink must...

Page 16: ...user configuration of the required parameters 2 4 Accessing web Interface The UPSLink supports both HTTP and HTTPS HTTP over SSL protocols The UPSLink also provides its own Web management pages To ac...

Page 17: ...apply or Cancel their actions After changing the configuration parameter values the users must select Save to flash or Save and apply to save the changed parameter values to the non volatile memory To...

Page 18: ...n UPS identification Shows basic information that identifies the UPS and UPSLink UPS test information Shows UPS test related information if there is any test ever been initiated since the last start u...

Page 19: ...here occurred any UPS alarms the alarm records are shown on this page in red colored font with their detected time The information about the current status and capability of Battery Input Output and B...

Page 20: ...ge A dedicated java applet communicates with UPSLink continuously through a separate TCP port TCP 9009 and this makes the gauges indicate the correct UPS status and capabilities in real time Be noted...

Page 21: ...Bypass group by pressing buttons at the top of the applet Figure 3 5 UPS status gauge Input 3 5 UPS configuration UPS parameters are user configurable on this web page Among them RFC1628 compliant pa...

Page 22: ...tion 3 6 UPS control Besides the parameter configurations the commands that control the UPS directly such as tests shutdown restart and reboot are offered in a separate page The test or control comman...

Page 23: ...or the SYSLOG server Hence the internal memory is a volatile to preserve the system log data set the storage location to be the SYSLOG server or NFS server To do this the user must configure the corr...

Page 24: ...there runs Sena s UPS serial program on the UPSLink The UPSLink reserves 100 kilobytes of user space for a private UPS serial program Users can choose the application that runs on the UPSLink See UPS...

Page 25: ...net protocols in setting up the UPSLink IP address i e Static IP DHCP Dynamic Host Configuration Protocol PPPoE Point to Point Protocol over Ethernet The UPSLink is initially defaulted to DHCP mode Ta...

Page 26: ...addresses to identify and talk to each other on a network Therefore it is imperative that the selected IP address be both unique and valid in a network environment Note 192 168 x x will never be assi...

Page 27: ...he secondary DNS server is specified for use when the primary DNS server is unavailable 4 1 2 Using DHCP Dynamic Host Configuration Protocol DHCP is a communications protocol that lets network adminis...

Page 28: ...Using PPPoE PPPoE Point to Point Protocol over Ethernet is a specification for connecting multiple computer users on an Ethernet LAN local area network to a remote site through a modem or similar devi...

Page 29: ...be notified of significant events TRAPs query a device for more information GET GET Next and make changes to the device state SET SNMPv2 adds a GET Bulk function to retrieve tables of information and...

Page 30: ...1213 4 2 2 Access control configuration Access Control defines accessibility of managers to the UPSLink SNMP agent Only a manager from the specified NMS can access UPSLink SNMP agent to exchange info...

Page 31: ...the off state 16 The failure of one or more fans in the UPS has been detected 17 The failure of one or more fuses has been detected 18 A general fault in the UPS has been detected 19 The result of th...

Page 32: ...e UPSLink through the hostname registered in the Dynamic DNS Server regardless of any IP address change By default the UPSLink only supports Dynamic DNS service offered at Dynamic DNS Network Services...

Page 33: ...dress Device mail address SMTP user name SMTP user password The device mail address specifies the sender s email address for all log and alarm delivery emails SMTP servers often check only the sender...

Page 34: ...sole To upload the new server certificate connect to the UPSLink s local system console and select 2 Network configuration 5 Access control 7 Upload server certificate from the menu See 2 3 1 Using sy...

Page 35: ...If the secondary SYSLOG server is configured the UPSLink will send the same SYSLOG messages to both servers Figure 4 6 SYSLOG server configuration To receive log messages from the UPSLink the SYSLOG s...

Page 36: ...he NFS service is enabled and the NFS server configuration is properly set up the user can specify the storage location for the UPSLink s system log or UPS alarm log as the NFS server For more informa...

Page 37: ...37 Figure 4 8 Ethernet mode configuration...

Page 38: ...ow control Figure 5 1 UART configuration Baud rate The valid baud rate for the UPSLink is as follows 1200 2400 4800 9600 14400 19200 38400 57600 115200 and 230400 The factory default setting is 19200...

Page 39: ...provides both the system logging feature and the system log display The user may configure the UPSLink to enable or disable the system logging process select the log storage location and configure th...

Page 40: ...configured to send system log daily if it reaches pre defined time If enabled the user must set parameters to initiate the creation of an email These parameters would include the time to trigger an e...

Page 41: ...he UPS administrator group has only read access to the other UPSLink configuration settings and do not have access to UPS monitoring application upload and configuration menu Some classified pages wil...

Page 42: ...nagement R W X X Language R W R W R W Date and Time R W R R Factory reset R W X X Firmware upgrade R W X X Reboot R W X X Table 7 2 User groups and their access privileges for web pages R W read and w...

Page 43: ...ng the password Figure 7 4 shows the remove a user screen Figure 7 4 Removing a user 7 2 Device name configuration The UPSLink has its own name for administrative purposes Figure 7 5 shows the device...

Page 44: ...re are two ways of doing this The first is to use the NTP server to maintain the date and time settings across rebooting If the NTP feature is enabled the UPSLink will obtain the date and time informa...

Page 45: ...s the factory default reset screen Figure 7 8 Factory default reset 7 6 Firmware upgrade Firmware upgrades are available via serial remote console or web interface The latest upgrades are available on...

Page 46: ...firmware upgrade menu as shown in Figure 7 10 4 Follow the online directions and transfer the firmware binary file using the Zmodem protocol as shown in Figure 7 11 5 Once the upgrade has been comple...

Page 47: ...setting 6 Firmware upgrade ESC Back ENTER Refresh 6 Firmware upgrade will RESTART your device Are you sure to start firmware upgrade y n y Preparing for firmware upgrade Wait a moment Transfer firmwar...

Page 48: ...esh 6 Firmware upgrade will RESTART your device Are you sure to start firmware upgrade y n y Preparing for firmware upgrade Wait a moment Transfer firmware by zmodem using your terminal application B0...

Page 49: ...White with orange 2 Tx Orange 3 Rx White with green 4 NC Blue 5 NC White with blue 6 Rx Green 7 NC White with brown 8 NC Brown Table A 1 Pin assignment of the RJ45 connector for Ethernet A 2 Serial p...

Page 50: ...9 connector A 3 Ethernet wiring diagram Figure A 3 Ethernet direct connection using crossover Ethernet cable Figure A 4 Ethernet connection using straight through Ethernet cable A 4 Serial wiring dia...

Page 51: ...ms executed by privileged users Table B 1 shows some of the well known port numbers For more details please visit the IANA website http www iana org assignments port numbers Port number Protocol TCP U...

Page 52: ...xZPnnD4 50 MHz DRAM 16 MB FLASH 4 MB EEPROM A Type exist Ethernet AUTO NEGOTIATION Autoboot Start 0 Welcome to Boot Loader Configuration page Select menu 1 Hardware test 2 Firmware upgrade S W Version...

Page 53: ...st with a valid IP address The default server IP address is 192 168 0 128 and it can be changed using the Firmware Upgrade menu Otherwise the test may not be performed properly Hardware Test Select me...

Page 54: ...PROM Test SUCCESS Ethernet Ethernet chip test SUCCESS PING 192 168 14 1 from 192 168 14 7 64 bytes of ethernet packet 64 bytes from 192 168 14 1 seq 0 ttl 255 timestamp 285068 ms 64 bytes from 192 168...

Page 55: ...default IP address for the unit is 192 168 161 5 For firmware upgrade a firmware file configured as Firmware File Name on the server configured as Server s IP address must exist Firmware upgrade Selec...

Page 56: ...TFTP from server 192 168 0 128 our IP address is 192 168 161 5 Filename upslink bin Load address 0x100000 Loading done Bytes transferred 3298122 32534a hex Erase Flash Sectors 0 1 in Bank 1 BLOCK 0 Co...