SD1000U has 4 response messages, ‘OK’, ‘ERROR’, ‘CONNECT’, and ‘DISCONNECT’. In some
cases, these responses can affect the host system unexpectedly. To prevent this, user can set the
Command response to ON or OFF.
For SD1000U, hardware flow control can be configured only by dip switch. And parity, stop bit can be
configured only SW config mode. Thus H/W Flow Control option will not work in this case. When the
dipswitch value isn’t ATcommand mode, the Baud Rate menu will be disabled.
Click [Apply] button to apply any changes made to the SD1000U.
Connection(out) icon will show the following window to search and connect other Bluetooth devices.
Figure 2-7 Connection (out) Window
Click [Search] button to search nearby Bluetooth devices. Once several Bluetooth devices has been
found, select one of the devices and click the [Connect] button. The selected Bluetooth device must be
discoverable and connectable. Click [Disconnect] button to cancel the connection.
After the connection has been established, you will be able to test signal strength by pushing the