background image

   

 

 
 

Coin Timer 

for 

Campground Shower 

and other 

Multiple Uses

 

July 2017 

 

 

 

 

 

 

# i01741 

Summary of Contents for 5500TX

Page 1: ...Coin Timer for Campground Shower and other Multiple Uses July 2017 i01741...

Page 2: ...vandalism compaRed to the previous Model 5000 The coin box was designed so that you do not need to remove the full face plate to access the money We believe this device will provide you with good ser...

Page 3: ...3 The 5500TX closed and with its coin box re moved counter clockwise to open clockwise to close...

Page 4: ...e It is your responsibility to make sure nobody can rip the timer off the wall Make sure elec trical connec tions meet the local electrical code If you are not familiar with electricity do not hesitat...

Page 5: ...coin acceptor MDB 4 Micro chip containing the entire memory parameters and audit 5 Connection for auxiliary terminal block 6 screws 6 Connection for main terminal block 12 screws 7 Location of Jumper...

Page 6: ...reference On the big block number 1 is on the left The big block has 12 screws 1 24vac In 2 24vac In 3 n a 4 n a 5 Dry contact NC if jumper JP1 is REMOVED 6 Dry contact C if jumper JP1 is REMOVED 7 D...

Page 7: ...witch Light Beeper The timer controls a water valve in a campground shower The payment peripherals could be coins only coins bills or coins bills credit card The type of peripheral will not affect the...

Page 8: ...nt setting or decrease a number Operator Mode There are five menus accessible to any person opening the timer Audit Gives you the accounting information Currency setting Allows you to decide which mon...

Page 9: ...re double In such a case one can be erased the other no The abbreviation Cumul indicates a cumulative non erasable counter Note the last line of the display indicates you what button to use and the ac...

Page 10: ...finally the session style As for the Technician Mode it allows programming parameters that are more technical and should be access by a competent person As a matter of fact accessing this section cann...

Page 11: ...en to save Red increase blue decrease green mode digit Session rate 01 00 Green to enter Session mode Green to enter Session mode Cash continuous Red to modify Minimum charge 01 00 Green to save In al...

Page 12: ...increase this digit of Blue to decrease Once the good value reached press the Green button to move digit Repeat the process until all digit are programmed Session rate This is where you program the p...

Page 13: ...rammed here does not need to be equal to the rate session You can have a rate session of 2 but require only 1 to start the time session Obviously this 1 inserted will equal half the time programmed in...

Page 14: ...liary Acc type Green to enter PAUSE limit time 10 minutes Green to enter Choice of letter and number Level 0 to 10 Yes or no None coin token 00 mm Warning 1 Green to enter Warning 2 Green to enter Aux...

Page 15: ...ly a specific ID to each of them You can have numbers and letters as well as some special characters like or When visible on the display press on the Green button and the first available space will bl...

Page 16: ...sited and the display will show the amount and the time it gives The manual mode requires the SLB module Switch Light Button and allows remote start The External control will start the time through an...

Page 17: ...is 30 00 Note that the output voltage is 24vdc see page 6 Minimum charge chrono Minimum Charge chrono is grace period following a time cycle where a cus tomer can add credits to the timer without havi...

Page 18: ...ters on a small portable serial printer avail able in option from SEM This print out is very useful if you have a fleet of timer to program Note that this printer is the same you can use to print the...

Page 19: ...e client specifically waives any claim or recourse it may have against SEM Inc in any of the above instances SEM Inc s obligation under this warranty is limited to correcting or at its option replacin...

Page 20: ...ent Even though the ut most attention was given to writing this manual errors may have slipped by unnoticed Any comments suggestions or errors should be sent directly to info sem ca Telephone 1 514 33...

Reviews: