background image

Selmo

 

Comfort technology division

“THESIS DUAL”

 

Electronic control for towel radiator 

Rev.  05 July 2015

Selmo 

Electronic

 

Via Pacinotti, 24 - 35030 Rubano 

(PD) Italy- Tel +39.049.8976761, Fax +39.049.8976085 - 

www.selmo.it

 

EN

 

 

 

DISPOSAL 

 

This product may not be treated as ordinary household waste. It has to be 
disposed in proper waste collection sites. In case of replacement it shall be 
returned to the distributor.  
Such an end-of-life treatment of the product will preserve the environment and 
will reduce consumption of natural resources. 
This symbol applied to the present product indicates the obligation to bring 
it to a proper waste collection site, in order to let it be disposed according to 
2002/96 / CE (RAEE - WEEE) directives. 

 

FIL-PILOTE

 

(Only for product versions equipped with "Fil-Pilote") 
The "Fil-Pilote" sub-function allows managing the device by a central control system that sets the 
operating mode for all the connected devices. 

 

-  In “Room thermostat” operative mode:

 

 

1. 

Standby: 

power off the heating element, the device remains active.

 

2. 

Comfort: 

maintains the "Comfort" temperature set by the user.

 

3. 

ECO: 

maintains the room temperature 3,5°C below the "Comfort" temperature.

 

4. 

Anti-freeze: 

maintains the room temperature at 7°C.

 

5. 

Eco-1: 

maintains the room temperature 1°C below the "Comfort" temperature.

 

6. 

Eco-2: 

maintains the room temperature 2°C below the "Comfort" temperature. 

 

- In “Towel Radiator thermostat” operative mode:

 

1. 

Standby: 

power off the heating element, the device remains active.

 

2. 

Comfort: 

maintains the "Comfort" temperature set by the user.

 

3. 

ECO: 

maintains the room temperature 10°C below the "Comfort" temperature.

 

4. 

Anti-freeze: 

maintains the room temperature at 7°C.

 

5. 

Eco-1: 

maintains the room temperature 4°C below the "Comfort" temperature.

 

6. 

Eco-2: 

maintains the room temperature 7°C below the "Comfort" temperature. 

 

 

STAND-BY

 

I

n "Stand-by" mode the heating element is powered off.

 

 

KEY LOCK

 

Press together the [Select] (5) and [Mode] (6) buttons for 5 seconds to lock all the buttons (except 
the [On/Stand-by] button). When key lock is activated, a “LO” indication is displayed on the screen.

 

To unlock the buttons, repeat the same procedure.

 

 

 

 

 

 
 
 
 
 
 

The manufacturer reserves the right to make any changes to the product 
described in this manual, at any time, and without prior warning.

 

 

Summary of Contents for Thesis Digital

Page 1: ...to install and it is available in different colors THESIS Dual is a certified product THESISDualis compliant with the following standards Eco design Directive for Energy using Products 2005 32 EC 0 5W...

Page 2: ...ifreeze Stand by Fil Pilote Timer 2h Operational modes Selectable temperature range of the towel radiator in Comfort mode 30 C 70 C Selectable temperature range of the room in Comfort mode 10 C 32 C O...

Page 3: ...supply before cleaning or performing maintenance of the product In case of damage of the power supply cable shut down the device and do not tamper with it The damaged power supply cables can be repla...

Page 4: ...power of the towel radiator Thesis dual is compatible with the type of heating elements shown in the following picture Earth connection Only Class I Female 4 poles connector to Thesis Dual Heating ele...

Page 5: ...irectives 9 The device has to be protected by a 30mA circuit breaker RCD 10 Power the device with the recommended voltage see technical specifications 11 If a device is directly connected to a fixed e...

Page 6: ...the Fil Pilote system can remotely control a Thesis Dual device with Fil Pilote functionality Class II The brown wire is the Live wire L the gray wire is the Neutral wire N and the black wire is used...

Page 7: ...stat regulation based on room temperature The selection between these two operative modes is done through the Select 5 button When the Room thermostat mode is active the led indicator 3 is turned on W...

Page 8: ...ed above Night Icon moon 10 it is similar to the Comfort function but the temperature range is between 9 C and 31 C in Room thermostat mode and between 29 C and 69 C in Towel radiator mode Antifreeze...

Page 9: ...ve 2 Comfort maintains the Comfort temperature set by the user 3 ECO maintains the room temperature 3 5 C below the Comfort temperature 4 Anti freeze maintains the room temperature at 7 C 5 Eco 1 main...

Reviews: