background image

Selmo

 

Comfort technology division

“THESIS DUAL”

 

Electronic control for towel radiator 

Rev.  05 July 2015

Selmo 

Electronic

 

Via Pacinotti, 24 - 35030 Rubano 

(PD) Italy- Tel +39.049.8976761, Fax +39.049.8976085 - 

www.selmo.it

 

EN

 

 

 

Installation guide

 

 

 

Make sure that the power of the electric resistance does not exceed the maximum 
power of the towel radiator

 

 

"Thesis dual" is compatible with the type of heating elements shown in the following picture

 

 
 
 

Earth connection 
(Only Class I)

 

Female 4 poles connector to "Thesis 
Dual"

 

 
 
 

Heating element

 

 
 
 
 

 

 
4 poles 
connector 
 
 

For use by installer only

 

WARNING: 
Disconnect the power supply before proceeding with installation.  
The installation has to be performed only by authorized personnel. 

IMPORTANT

:  Do not try to use or adapt 

a different type of connector order to 
prevent damages to the heating system.

 

YES

 

NO

Summary of Contents for Thesis Digital

Page 1: ...to install and it is available in different colors THESIS Dual is a certified product THESISDualis compliant with the following standards Eco design Directive for Energy using Products 2005 32 EC 0 5W...

Page 2: ...ifreeze Stand by Fil Pilote Timer 2h Operational modes Selectable temperature range of the towel radiator in Comfort mode 30 C 70 C Selectable temperature range of the room in Comfort mode 10 C 32 C O...

Page 3: ...supply before cleaning or performing maintenance of the product In case of damage of the power supply cable shut down the device and do not tamper with it The damaged power supply cables can be repla...

Page 4: ...power of the towel radiator Thesis dual is compatible with the type of heating elements shown in the following picture Earth connection Only Class I Female 4 poles connector to Thesis Dual Heating ele...

Page 5: ...irectives 9 The device has to be protected by a 30mA circuit breaker RCD 10 Power the device with the recommended voltage see technical specifications 11 If a device is directly connected to a fixed e...

Page 6: ...the Fil Pilote system can remotely control a Thesis Dual device with Fil Pilote functionality Class II The brown wire is the Live wire L the gray wire is the Neutral wire N and the black wire is used...

Page 7: ...stat regulation based on room temperature The selection between these two operative modes is done through the Select 5 button When the Room thermostat mode is active the led indicator 3 is turned on W...

Page 8: ...ed above Night Icon moon 10 it is similar to the Comfort function but the temperature range is between 9 C and 31 C in Room thermostat mode and between 29 C and 69 C in Towel radiator mode Antifreeze...

Page 9: ...ve 2 Comfort maintains the Comfort temperature set by the user 3 ECO maintains the room temperature 3 5 C below the Comfort temperature 4 Anti freeze maintains the room temperature at 7 C 5 Eco 1 main...