Selmo
Comfort technology division
“THESIS DUAL”
Electronic control for towel radiator
Rev. 05 July 2015
Selmo
Electronic
Via Pacinotti, 24 - 35030 Rubano
(PD) Italy- Tel +39.049.8976761, Fax +39.049.8976085 -
www.selmo.it
EN
Connection to Fil-Pilote system
(Only for product versions equipped with "Fil-Pilote")
Example
1. A control unit supporting the "Fil-Pilote" system can remotely control a
Thesis Dual device with "Fil-Pilote" functionality (Class II). The brown wire is
the Live wire (L), the gray wire is the Neutral wire (N) and the black wire is
used for receiving the Fil-Pilote signal.
Do not connect the black wire to the ground.
2. A Thesis Dual device without "Fil-Pilote" functionality (Class I) cannot be
remotely controlled. The brown wire is the Live wire (L), the blue wire is the
Neutral wire (N) and the yellow/green wire has to be connected to Earth.
Fil
‐
Pilote
Fil
‐
Pilote
Station