Connection to Fil-Pilote system

 

(Only for product versions equipped with "Fil-Pilote")

 

 

 
Example 

 

 
 
 
 
 
 
 

 

 
 

1.  A control unit supporting the "Fil-Pilote" system can remotely control a 

Thesis Dual device with "Fil-Pilote" functionality (Class II). The brown wire is 
the Live wire (L), the gray wire is the Neutral wire (N) and the black wire is 
used for receiving the Fil-Pilote signal. 

Do not connect the black wire to the ground.  

 
 
2.  A Thesis Dual device without "Fil-Pilote" functionality (Class I) cannot be 

remotely controlled. The brown wire is the Live wire (L), the blue wire is the 
Neutral wire (N) and the yellow/green wire has to be connected to Earth.

 

Fil

Pilote

Fil

Pilote

 

Station

Summary of Contents for Thesis Digital

Page 1: ...to install and it is available in different colors THESIS Dual is a certified product THESISDualis compliant with the following standards Eco design Directive for Energy using Products 2005 32 EC 0 5W...

Page 2: ...ifreeze Stand by Fil Pilote Timer 2h Operational modes Selectable temperature range of the towel radiator in Comfort mode 30 C 70 C Selectable temperature range of the room in Comfort mode 10 C 32 C O...

Page 3: ...supply before cleaning or performing maintenance of the product In case of damage of the power supply cable shut down the device and do not tamper with it The damaged power supply cables can be repla...

Page 4: ...power of the towel radiator Thesis dual is compatible with the type of heating elements shown in the following picture Earth connection Only Class I Female 4 poles connector to Thesis Dual Heating ele...

Page 5: ...irectives 9 The device has to be protected by a 30mA circuit breaker RCD 10 Power the device with the recommended voltage see technical specifications 11 If a device is directly connected to a fixed e...

Page 6: ...the Fil Pilote system can remotely control a Thesis Dual device with Fil Pilote functionality Class II The brown wire is the Live wire L the gray wire is the Neutral wire N and the black wire is used...

Page 7: ...stat regulation based on room temperature The selection between these two operative modes is done through the Select 5 button When the Room thermostat mode is active the led indicator 3 is turned on W...

Page 8: ...ed above Night Icon moon 10 it is similar to the Comfort function but the temperature range is between 9 C and 31 C in Room thermostat mode and between 29 C and 69 C in Towel radiator mode Antifreeze...

Page 9: ...ve 2 Comfort maintains the Comfort temperature set by the user 3 ECO maintains the room temperature 3 5 C below the Comfort temperature 4 Anti freeze maintains the room temperature at 7 C 5 Eco 1 main...