Operation section
User and service manual
– TOP EX – Continuous tempering machine
25
5.4. Position of the user
During the working cycle a sole operator is needed
located in front of the working panel with easy access
to the emergency button.
5.5. Involuntary electrical interruptions
If the voltage supply were to fail during the working
cycle, restart the machine as described in section 5.3.
5.6. End of the working cycle
If, at the end of the working cycle, the user wishes to
leave in the tank some residual chocolate it is
recommended to carry out the following operations:
If the “temper function” is active, press button
(F) to deactivate this function.
Wait for a few minutes until the nozzle chocolate
temperature has increased to about 36°C.
Press in sequence the following buttons:
(E) PUMP MOTOR
(C) MIXER
(B) PREWARM
to bring the machine to STAND-BY (led light D
on).
Now the machine can be turned off by pressing the red
button on the main switch.
Note
At the end of the working cycle cover the
chocolate tank with the supplied lid.
5.7 Warning messages
Warning or fault messages could appear while the
machine is in use depending on the conditions
detected by the electronic system:
A L L
P r O
This message notifies the user that the tank protection
grill has been removed.
A L 1
A L 1
The sensor located on the nozzle has detected an
abnormal temperature (lower than 0°C or higher than
65°C); it is likely that the probe has been damaged and
needs to be replaced.
A L 2
A L 2
Same as the previous but concerning the column
probe
A L 3
A L 3
Same as the previous but concerning the tank probe
A L 4
A L 4
Same as the previous but concerning the cooler circuit
probe
A L 5
A L 5
Same as the previous but concerning the duct
probe
A L 6
A L 6
Same as the previous but concerning the second tank
probe
A S S
N A
Mixer motor abnormal power consumption
A S S
N r
Chocolate pump motor abnormal power consumption
A S S
2 2 0
Abnormal power consumption of a 230V power supply
A S S
2 4
Abnormal power consumption of a 24V power supply
Summary of Contents for TOP EX
Page 1: ...TOP EX User and service manual Page not to be printed...
Page 43: ...Maintenance section User and service manual TOP EX Continuous tempering machine 41...
Page 44: ...Maintenance section User and service manual TOP EX Continuous tempering machine 42...
Page 45: ...Maintenance section User and service manual TOP EX Continuous tempering machine 43...
Page 46: ...Maintenance section User and service manual TOP EX Continuous tempering machine 44...
Page 47: ...Maintenance section User and service manual TOP EX Continuous tempering machine 45...
Page 48: ...Maintenance section User and service manual TOP EX Continuous tempering machine 46...
Page 49: ...Maintenance section User and service manual TOP EX Continuous tempering machine 47...
Page 50: ...Maintenance section User and service manual TOP EX Continuous tempering machine 48...