Options | Irradiation and Temperature Sensor
54 | Doc. No. 982056, Version 01, SelectSun 40K
8 Options
8.1
Irradiation and Temperature Sensor
For recording the irradiation and the module temperature, an irradiation and temperature sensor can be
connected to the sensor interface of the inverter.
The sensor comes with a 3 meter UV-resistant connecting line (5 x 0.14 mm²). The line can be extended with
a 5 x AWG 23 (0.25 mm²) shielded line, max. 328 ft (100 m).
8.1.1
Inverter Sensor Interface
Fig. 21: Connector M12 x 1 straight, shielded; pole arrangement: male M12, 5 pins, A-coded, view of male connector
side, PHOENIX CONTACT designation: SACC-M12MS-5SC SH
Inverter sensor
pins
Signal
Pin 1
Supply voltage (24 VDC, max. 2 W)
Pin 2
Ground
Pin 3
Signal Input 1 (0-10 V)
Pin 4
Signal Input 2 (0-10 V)
Pin 5
Shield
8.1.2
Sensor Type Si-13TC-T-K Cable
Sensor cable color
Signal
Red
Supply voltage (12-28 VDC)
Black
Ground
Orange
Measurement signal irradiation (0-10 V)
Brown
Measurement signal temperature (0-10 V)
Black, thick
Shield