44
13
Pulsed duty cycle
Allows regulation of the duty cycle in pulse welding.
Allows the peak current to be maintained for a shorter
or longer time.
Parameter setting: percentage (%).
Minimum 1%, Maximum 99%, Default 50%
14
Fast Pulse frequency
Allows regulation of the pulse frequency.
Allows focusing action and better stability of the electric
arc to be obtained.
Parameter setting: KiloHertz (kHz).
Minimum 0.02KHz, Maximum 2.5KHz, Default off
15 Pulsed
slopes
Allows setting of a slope time during the pulse operation.
Allows a smooth step to be obtained between the peak current
and the basic current, having a more or less soft welding arc.
Parameter setting: percentage (%).
Minimum off, Maximum 100%, Default off
16 Slope-down
Allows you to set a gradual passage between the weld-
ing current and the final current.
Parameter set in seconds (s).
Minimum off, Maximum 99.9s, Default off
17 Final
current
Permits adjustment of the final current.
Parameter set in Amps (A).
Minimum 3A-1%, Maximum Imax-500%, Default 10A
19
Final current time
Makes it possible to set the time for which the final cur-
rent is maintained.
Parameter setting: seconds (s).
Minimum off, Maximum 99.9s, Default off
20 Post-gas
Permits setting and adjustment of the gas flow at the
end of welding.
Minimum 0.0s, Maximum 99.9s, Default syn
203
Tig start (HF)
Allows selection of the required arc striking modes.
Off=LIFT START, On= HF START, Default HF START
204 Spot
welding
A
llows you to enable the "spot welding" process and
establish the welding time.
Allows the timing of the welding process.
Parameter setting: seconds (s).
Minimum off, Maximum 99.9s, Default off
205 Restart
Allows the activation of the restart function.
Allows the immediate extinguishing of the arc during
the down slope or the restarting of the welding cycle.
Default
On
206
(TIG DC) Easy joining
Allows striking of the arc in pulsed current and timing
of the function before the automatic reinstatement of
the pre-set welding conditions.
Allows greater speed and accuracy during tack welding
operations on the parts.
Parameter setting: seconds (s).
Minimum 0.1s, Maximum 25.0s, Default off
500
Allows the selection of the required graphic interface:
XE (Easy Mode)
XA (Advanced Mode)
XP (Professional Mode)
Allows access to the higher set-up levels:
USER:
user
SERV:
service
SELCO:
Selco
551 Lock/unlock
Allows the locking of the panel controls and the inser-
tion of a protection code (consult the “Lock/unlock”
section).
552 Buzzer
tone
Permits adjustment of the buzzer tone.
Minimum Off, Maximum 10, Default 10
553
Contrast (LCD 4.7")
Permits adjustment of the display contrast.
Minimum -20, M20
601 Adjustment
step
Permits adjustment of the variation step on the up-
down keys.
Minimum Off, Maximum MAX, Default 1
602
CH1, CH2, CH3, CH4 External parameter
Allows the management of external parameter 1 (mini-
mum value, maximum value, default value, parameter
selected).
(Consult the “External controls management” section).
606 U/D torch
Allows the management of the external parameter
(CH1) (parameter selected).
751 Current
reading
Allow the real value of the welding current to be dis-
played.
Allows the welding current display method to be set
(consult the “Interface personalisation” section).
752 Voltage
reading
Allows the real value of the welding voltage to be dis-
played.
Allows the welding voltage display method to be set
(consult the “Interface personalisation” section).
801 Guard
limits
Allows the setting of the warning limits and of the guard
limits.
Allows the accurate control of the various welding
phases (consult the “Guard limits” section).
List of set up parameters (MIG/MAG-Pulsed MIG)
0
Save and quit
Allows you to save the changes and exit the set up.
1
Reset
Allows you to reset all the parameters to the default
values.
2 Synergy
Allows selection of the manual MIG (
) or syner-
gic MIG (
) process by setting the type of mate-
rial to be welded.
(Consult the “Synergic curves screen” section).
3
Wire speed
Allows the regulation of the wire feed rate.
Minimum 0.5 m/min, Maximum 22 m/min
4
Current
Allows the regulation of the welding current.
Minimum 6A, Maximum Imax
5 Part
thickness
Allows the thickness of the part being welded to be set.
Allows the setting of the system via the regulation of the
part being welded.
6 Corner
bead
Lets you set bead depth in a corner joint.
Summary of Contents for Genesis 3200 GSM
Page 32: ...32...
Page 90: ...90...
Page 120: ...120...
Page 150: ...150...
Page 180: ...180...
Page 210: ...210...
Page 326: ...326 1 3 1 4 11 35 1 5 1 6...
Page 327: ...327 8 1 7 EN IEC 60974 10 B A A EN60974 10 A pace maker Zmax Ssc Point of Commom Coupling PCC...
Page 328: ...1 8 IP S IP23S 12 5 mm 60 2 2 1 2 2 10 2 3 400V 230V 15 15 2 1 5 328...
Page 344: ...5 6 Reset 344...
Page 345: ...345 encoder...
Page 346: ...346...
Page 347: ...347 7 7 1 MMA Hot Start Arc Force antisticking 7 2 TIG TIG Tungsten lnert Gas 3370 C H F lift...
Page 352: ...352...
Page 357: ...357...
Page 360: ...360...