38
15 Final
current
Permits adjustment of the final current.
Parameter set in Amps (A).
Minimum 3A-1%, Maximum Imax-500%, Default 50%
17 Post-gas
Permits setting and adjustment of the gas flow at the
end of welding.
Minimum 0.0s, Maximum 99.9s, Default 5.0s
18
TIG start (LIFT)
Allows selection of the required arc striking modes.
On= HF START, Off= LIFT START, Default HF START
22 Spot
welding
A
llows you to enable the "spot welding" process and
establish the welding time.
Allows the timing of the welding process.
Parameter setting: seconds (s).
Minimum off, Maximum 99.9s, Default 1.0s
25 Wire
speed
Allows the regulation of the wire feed rate.
Parameter setting: mm/s.
Minimum 1 mm/s, Maximum 200 mm/s, Default Off
26
Wire start delay
Parameter setting: seconds (s).
Minimum 0.1s, Maximum 99.9s, Default Off
27
Wire stop advance/delay
Parameter setting: seconds (s).
Minimum 0.1s, Maximum 99.9s, Default Off
28 Wire
withdrawal
Parameter setting: seconds (s).
Minimum 0.01s, Maximum 1.00s, Default 0.10s
29 Slope-down
Parameter setting: seconds (s).
Minimum 0.0s, Maximum 10.0s, Default 0.0s
30
Basic wire speed
Parameter setting: percentage (%).
Minimum 0%, Maximum 100%, Default 0%
100%
=
0%
=
0
= wire withdrawal
31
Slope-up (wire speed)
Parameter setting: seconds (s).
Minimum 0.0s, Maximum 10.0s, Default 0.0s
32
Pulsed frequency (wire speed)
Allows activation of the pulse mode.
Permits adjustment of the pulse frequency.
Parameter set in Hertz (Hz).
Minimum 0.1Hz, Maximum 5.0Hz, Default Off
0.1÷5.0Hz pulsed frequency (wire speed)
off
pulsed frequency (wire speed) = 0
syn
pulsed frequency (wire speed) =
pulsed frequency (current)
33
Duty cycle (wire speed)
Allows regulation of the duty cycle in pulse welding.
Parameter setting: percentage (%).
Minimum 1%, Maximum 99%, Default 50%
34
Unbalance (wire speed)
Parameter setting: percentage (%).
Minimum -50%, M50%, Default 0%
37 Guard
limits
Allows the setting of the warning limits and of the guard
limits.
Allows the accurate control of the various welding
phases (consult the “Guard limits” section).
38 Starting
filter
Allows the control of the guard limits to be enabled
with an adjustable delay in relation to the arc striking.
Makes it possible to filter the striking phase (consult the
“Guard limits” section).
Minimum 0.0s, Maximum 10.0s, Default 0.0s
39 Output
filter
Makes it possible to disenable the control of the guard
limits in advance of the natural closing of the weld.
Makes it possible to filter the extinction phase (consult
the “Guard limits” section).
Minimum 0.0s, Maximum 10.0s, Default 0.0s
40 Current
reading
Allow the real value of the welding current to be dis-
played.
Allows the welding current display method to be set
(consult the “Interface personalisation” section).
41 Voltage
reading
Allows the real value of the welding voltage to be dis-
played.
Allows the welding voltage display method to be set
(consult the “Interface personalisation” section).
42
Gas flow reading
44
(U/D) Adjustment step
Permits adjustment of the variation step on the up-
down keys.
Minimum Off, Maximum MAX, Default 1
45
CH1 External parameter
Allows the management of external parameter 1 (mini-
mum value, maximum value).
(Consult the “External controls management” section).
46
CH2 External parameter
Allows the management of external parameter 1 (mini-
mum value, maximum value).
(Consult the “External controls management” section).
47 Lock/unlock
Allows the locking of the panel controls and the inser-
tion of a protection code (consult the “Lock/unlock”
section).
48 Buzzer
tone
Permits adjustment of the buzzer tone.
Minimum Off, Maximum 10, Default 5
49 Contrast
Permits adjustment of the display contrast.
Minimum 0, Maximum 50, Default 25
50
Allows access to the higher set-up levels:
USER:
user
SERV:
service
SELCO:
Selco
99 Reset
Allows the resetting of all parameters to the default
values.
Allows the resetting of the whole graphic interface
according to the manufacturer’s settings.
3.9 Programs screen
1 General
Allows the storage and management of 50 welding pro-
grams which can be personalised by the operator.
Summary of Contents for Genesis 284 PSR
Page 50: ...50...
Page 76: ...76...
Page 102: ...102...
Page 198: ...198...
Page 270: ...270...
Page 274: ...274 1 3 1 4 11 35 1 5...
Page 275: ...275 1 6 8 1 7 EN IEC 60974 10 B A A EN60974 10 A pace maker Point of Commom Coupling PCC...
Page 276: ...1 8 IP S IP23S 12 5 mm 60 2 2 1 2 2 10 2 3 400V 15 15 2 1 5 276...
Page 277: ...277 2 4 MMA 1 2 3 4 TIG 1 2 TIG 3 4 1 2 3 4...
Page 284: ...284 3 9 1 50 1 3 3a 3b 3c 3d 3e 2 encoder 1 1 4 encoder encoder 1 4 4 3 encoder 2...
Page 290: ...290 4 5 MT300 5 6...
Page 291: ...291 Reset encoder...
Page 292: ...292...
Page 296: ...296...
Page 300: ...GENESIS 504 PSR 300...
Page 304: ...304...